119 resultados para Tests accuracy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the serological cross-reactivity between Leishmania sp. and other canine pathogens. Methods: Positive serum samples for Ehrlichia canis, Babesia canis, Toxoplasma gondii, Neospora caninum and Trypanosoma cruzi were tested using three serological methods enzyme linked immunosorbent assay (ELISA), indirect immunofluorescent antibody test (IFAT) and Kalazar Detect™, for canine visceral leishmaniasis. Results: Of the 57 dog samples tested, 24 (42.1%) tested positive using one of the three serological methods: 10/57 (17.5%) for ELISA, 11/57 (19.3%) for IFAT and 3/57 (5.3%) for Kalazar Detect™. Conclusions: Our results demonstrated that the presence of other infectious agents may lead to cross-reactivity on leishmaniasis serological tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study evaluated the level of concordance between hybrid capture II (HCII) and PapilloCheck® for the detection of high-risk human papillomavirus (HPV) in anal samples. Methods Anal cell samples collected from 42 human immunodeficiency virus (HIV)+ patients were analyzed. Results Considering only the 13 high-risk HPV types that are detectable by both tests, HCII was positive for 52.3% of the samples, and PapilloCheck® was positive for 52.3%. The level of concordance was 80.9% (Kappa = 0.61). Conclusions Good concordance was observed between the tests for the detection of high-risk HPV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Since the launch of the Global Programme to Eliminate Lymphatic Filariasis, more than 70% of the endemic countries have implemented mass drug administration (MDA) to interrupt disease transmission. The monitoring of filarial infection in sentinel populations, particularly schoolchildren, is recommended to assess the impact of MDA. A key issue is choosing the appropriate tools for these initial assessments (to define the best intervention) and for monitoring transmission. Methods This study compared the pre-MDA performance of five diagnostic methods, namely, thick film test, Knott's technique, filtration, Og4C3-ELISA, and the AD12-ICT card test, in schoolchildren from Brazil. Venous and capillary blood samples were collected between 11 pm and 1 am. The microfilarial loads were analyzed with a negative binomial regression, and the prevalence and associated 95% confidence intervals were estimated for all methods. The accuracies of the AD12-ICT card and Og4C3-ELISA tests were assessed against the combination of parasitological test results. Results A total of 805 schoolchildren were examined. The overall and stratified prevalence by age group and gender detected by Og4C3-ELISA and AD12-ICT were markedly higher than the prevalence estimated by the parasitological methods. The sensitivity of the AD12-ICT card and Og4C3-ELISA tests was approximately 100%, and the positive likelihood ratios were above 6. The specificity of the Og4C3-ELISA was higher than that of the AD12-ICT at different prevalence levels. Conclusions The ICT card test should be the recommended tool for monitoring school-age populations living in areas with ongoing or completed MDA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Various methods are used for the diagnosis of visceral leishmaniasis (VL), such as microscopic examination, culture and inoculation of laboratory animals; however, serological assays are commonly used for the detection of antibodies in serum samples with a wide range of specificity and sensitivity. METHODS: The purpose of this study was to compare three serological methods, including rA2-ELISA, the recombinant KE16 (rKE16) dipstick test and the direct agglutination test (DAT), for the detection of antibodies against VL antigens. The assays utilized 350 statistically based random serum samples from domestic dogs with clinical symptoms as well as samples from asymptomatic and healthy dogs from rural and urban areas of the Meshkinshahr district, northwestern Iran. RESULTS: Samples were assessed, and the following positive rates were obtained: 11.5% by rKE16, 26.9% by DAT and 49.8% by ELISA. The sensitivity among symptomatic dogs was 32.4% with rKE16, 100% with DAT and 52.9% with ELISA. Conversely, rA2-ELISA was less specific for asymptomatic dogs, at 46.5%, compared with DAT, at 88.9%. CONCLUSIONS : This study recommends rA2-ELISA as a parallel assay combined with DAT to detect VL infection among dogs. Further evaluations should be performed to develop an inexpensive and reliable serologic test for the detection of Leishmania infantum among infected dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: INTRODUCTION : Molecular analyses are auxiliary tools for detecting Koch's bacilli in clinical specimens from patients with suspected tuberculosis (TB). However, there are still no efficient diagnostic tests that combine high sensitivity and specificity and yield rapid results in the detection of TB. This study evaluated single-tube nested polymerase chain reaction (STNPCR) as a molecular diagnostic test with low risk of cross contamination for detecting Mycobacterium tuberculosis in clinical samples. METHODS: Mycobacterium tuberculosis deoxyribonucleic acid (DNA) was detected in blood and urine samples by STNPCR followed by agarose gel electrophoresis. In this system, reaction tubes were not opened between the two stages of PCR (simple and nested). RESULTS: STNPCR demonstrated good accuracy in clinical samples with no cross contamination between microtubes. Sensitivity in blood and urine, analyzed in parallel, was 35%-62% for pulmonary and 41%-72% for extrapulmonary TB. The specificity of STNPCR was 100% in most analyses, depending on the type of clinical sample (blood or urine) and clinical form of disease (pulmonary or extrapulmonary). CONCLUSIONS: STNPCR was effective in detecting TB, especially the extrapulmonary form for which sensitivity was higher, and had the advantage of less invasive sample collection from patients for whom a spontaneous sputum sample was unavailable. With low risk of cross contamination, the STNPCR can be used as an adjunct to conventional methods for diagnosing TB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: An integrative literature review was conducted to synthesize available publications regarding the potential use of serological tests in leprosy programs. We searched the databases Literatura Latino-Americana e do Caribe em Ciências da Saúde, Índice Bibliográfico Espanhol em Ciências da Saúde, Acervo da Biblioteca da Organização Pan-Americana da Saúde, Medical Literature Analysis and Retrieval System Online, Hanseníase, National Library of Medicine, Scopus, Ovid, Cinahl, and Web of Science for articles investigating the use of serological tests for antibodies against phenolic glycolipid-I (PGL-I), ML0405, ML2331, leprosy IDRI diagnostic-1 (LID-1), and natural disaccharide octyl-leprosy IDRI diagnostic-1 (NDO-LID). From an initial pool of 3.514 articles, 40 full-length articles fulfilled our inclusion criteria. Based on these papers, we concluded that these antibodies can be used to assist in diagnosing leprosy, detecting neuritis, monitoring therapeutic efficacy, and monitoring household contacts or at-risk populations in leprosy-endemic areas. Thus, available data suggest that serological tests could contribute substantially to leprosy management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: INTRODUCTION: Acceptance of the IT LEISH(r) and direct agglutination test- made in the Laboratório de Pesquisas Clínicas (DAT-LPC) by healthcare professionals and patients suspected of visceral leishmaniasis (VL) in Ribeirão das Neves was evaluated. METHODS: Ninety-two patients and 47 professionals completed three questionnaires. RESULTS: Eighty-eight (96%) patients considered fingertip blood collection a positive test feature, and 86% (37) and 91% of professionals considered the IT LEISH(r) easy to perform and interpret, respectively. All professionals classified the DAT-LPC as simple and easy. CONCLUSIONS: Patients and healthcare professionals in Ribeirão das Neves demonstrated a high degree of acceptance of the IT LEISH(r) and DAT-LPC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liver function and its correlation with bilirubin and hepatic enzymes were evaluated in 30 male chronic asymptomatic or oligosymptomatic alcoholics admitted into the psychiatric hospital for detoxification and treatment of alcoholism. Hypoalbuminemia, lowered prothrombin activity, hypotransferrinemia and hypofibrinogenemia were detected in 32 %, 32 %, 28 %, and 24 % of patients, respectively. Transferrin was elevated in 8 %. Greater prevalence of hyperbilirubinemia was found in patients with lowered prothrombin activity, hypofibrinogenemia, or hypotransferrinemia. No correlation was found between serum bilirubin or aminotransferase levels and normal or elevated albumin levels, time or activity of prothrombin, and fibrinogen levels. Serum alkaline phosphatase was elevated in normoalbuminemics and gamma-glutamyltransferase in patients with lowered prothrombin activity. Hypoalbuminemia was associated with hypofibrinogenemia, hypotransferrinemia with elevated aspartate aminotransferase or gamma-glutamyltransferase, and hypertransferrinemia with elevation of alanine aminotransferase. These data indicated the occurrence of hepatic dysfunction due to liver damage caused directly by alcohol or by alcoholism-associated nutritional deficiencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Compare pattern of exploratory eye movements during visual scanning of the Rorschach and TAT test cards in people with schizophrenia and controls. METHOD: 10 participants with schizophrenia and 10 controls matched by age, schooling and intellectual level participated in the study. Severity of symptoms was evaluated with the Positive and Negative Syndrome Scale. Test cards were divided into three groups: TAT cards with scenes content, TAT cards with interaction content (TAT-faces), and Rorschach cards with abstract images. Eye movements were analyzed for: total number, duration and location of fixation; and length of saccadic movements. RESULTS: Different pattern of eye movement was found, with schizophrenia participants showing lower number of fixations but longer fixation duration in Rorschach cards and TAT-faces. The biggest difference was observed in Rorschach, followed by TAT-faces and TAT-scene cards. CONCLUSIONS: Results suggest alteration in visual exploration mechanisms possibly related to integration of abstract visual information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the sphygmomanometers calibration accuracy and the physical conditions of the cuff-bladder, bulb, pump, and valve. METHODS: Sixty hundred and forty five aneroid sphygmomanometers were evaluated, 521 used in private practice and 124 used in hospitals. Aneroid manometers were tested against a properly calibrated mercury manometer and were considered calibrated when the error was <=3mm Hg. The physical conditions of the cuffs-bladder, bulb, pump, and valve were also evaluated. RESULTS: Of the aneroid sphygmomanometers tested, 51% of those used in private practice and 56% of those used in hospitals were found to be not accurately calibrated. Of these, the magnitude of inaccuracy ranged from 4 to 8mm Hg in 70% and 51% of the devices, respectively. The problems found in the cuffs - bladders, bulbs, pumps, and valves of the private practice and hospital devices were bladder damage (34% vs. 21%, respectively), holes/leaks in the bulbs (22% vs. 4%, respectively), and rubber aging (15% vs. 12%, respectively). Of the devices tested, 72% revealed at least one problem interfering with blood pressure measurement accuracy. CONCLUSION: Most of the manometers evaluated, whether used in private practice or in hospitals, were found to be inaccurate and unreliable, and their use may jeopardize the diagnosis and treatment of arterial hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To verify whether the serum levels of N-Terminal ProBNP fraction (ProBNP) allow us to identify with accuracy the clinical functional status of patients with heart failure (HF), because the clinical diagnosis of this syndrome is based basically on clinical data when the complementary tests have lower specificity. METHODS: Sixty-nine patients with a history of HF were studied. Their mean age of was 53.5 years and 78.3% were males. All underwent clinical and echocardiographic evaluations and a test to determine the serum dosage of ProBNP. According to clinical manifestation, patients were in the following functional classes (FC), 14% FC I, 40.6% FC II, 28.1% FC III, and 23.4% FC IV. The mean ejection fraction (EF) was 0.28. RESULTS: ProBNP did not differ according to age, sex, and cause of cardiopathy. No correlation existed between EF and the ProBNP serum level. ProBNP levels were significantly lower in patients in FC I than those in FC II (42 vs 326.7 pmol/L; P=0.0001), and in FC II than those in FC III (P=0.01). ProBNP levels did not differ statically between FC III and IV patients (888.1 vs 1082.8 pmol/L; P=0.25). ProBNP values greater than 100 pmol/L identify patients with decompensated HF with a sensitivity of 98%. CONCLUSION: ProBNP values over 100 pmol/L were indicative of HF, and patients with advanced HF had values over 270 pmol/L. A ProBNP dosage test was an excellent auxiliary in the clinical characterization of patients with HF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM). Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM) as gold-standard and measurements taken before morning micturition (BM) and in the afternoon (AM), for the best diagnosis of systemic arterial hypertension (SAH), and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women) were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM); and with post-morning-micturition and evening measurements (PM+EM). All patients underwent echocardiography (for left ventricular hypertrophy - LVH) and urinary albumin measurement (for microalbuminuria - MAU). Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM) and (PM+EM), and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM) versus (PM+EM) were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM) and (PM+EM) were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee. Results: The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical and serological follow up examinations were performed on 203 persons, from three to twenty years of age, from the otolaryngology department of a hospital in the city of Rio de Janeiro, with no symptomatology suggesting toxoplasmosis, but suffering from chronic tonsillitis. According to results obtained during the first indirect immunofluorescence tests, the patients were divided into following groups: Group I (non-reactive IgG and IgM), 98 persons (48.3%); Group II (1:16 ≤ IgG ≤ 1:256 and non-reactive IgM), 74 persons (36.5%); Group III (IgM ≥ 1:1024 and non-reactive IgM), 18 persons (8.8%), and Group IV (IgG and IgM reactive), 13 persons (6.4%). One to two years later, 131 (64.5%) of the 203 persons were reexamined by a second indirect immunofluorescence test. In the case of 66 persons (Group I) whose serum was non-reactive in the IgG and IgM classes during the first indirect immunofluorescence test, serum conversion was observed in aproximately 21.2%. in 65 individuals (49.6%), (Groups II, III and IV),with reactive serum in the IgG classes during the first indirect immunofluorescence test, the second reaction showed an increase in titres in 20% of the cases, a decrease in 67.7% of the cases, or no alterations in 12.3 of the cases. In the IgM class, all 131 sera were non-reactive at 116 dilution the second immunofluorescence test, including the 13 cases that had previously been reactive in the immunoglobulin class, Symptomatology suggesting toxoplasmosis was only observed in one case during the second testing, this patient's principal physical sign being hypertrophied lymph nodes. during this period, the Toxoplasma antibodies showed titres of IgG 1:32000 and non-reactive IgM, whilst one year previously, during the first test, these titres were IgG 1:1024 and IgM 1:64. Differences in the age, sex and skin coloring of patients were not statistically significant as regards alterations in the indirect immunofluorescence test titres.