69 resultados para SimplexaTM Dengue real-time RT-PCR
Resumo:
This study aimed to quantify Toxoplasma gondii in tissue samples of serologically positive chickens using real-time polymerase chain reaction (PCR). Of 65 chickens evaluated, 28 were positive for T. gondii antibodies. Brain and heart samples were collected from 26 seropositive chickens and DNA was extracted using Trizol® and amplified using real-time PCR with SYBR® Green. Parasite DNA was detected in 24 of the 26 samples analyzed; the number of positive tissue samples and the parasite quantity did not differ between tissue types. The results confirmed the analytical sensitivity of parasite detection in chicken tissue samples and demonstrated the possibility of using other molecular systems for genotypic analysis.
Resumo:
The introduction of newer molecular methods has led to the discovery of new respiratory viruses, such as human metapneumovirus (hMPV) and human bocavirus (hBoV), in respiratory tract specimens. We have studied the occurrence of hMPV and hBoV in the Porto Alegre (PA) metropolitan area, one of the southernmost cities of Brazil, evaluating children with suspected lower respiratory tract infection from May 2007-June 2008. A real-time polymerase chain reaction method was used for amplification and detection of hMPV and hBoV and to evaluate coinfections with respiratory syncytial virus (RSV), influenza A and B, parainfluenza 1, 2 and 3, human rhinovirus and human adenovirus. Of the 455 nasopharyngeal aspirates tested, hMPV was detected in 14.5% of samples and hBoV in 13.2%. A unique causative viral agent was identified in 46.2% samples and the coinfection rate was 43.7%. For hBoV, 98.3% of all positive samples were from patients with mixed infections. Similarly, 84.8% of all hMPV-positive results were also observed in mixed infections. Both hBoV and hMPV usually appeared with RSV. In summary, this is the first confirmation that hMPV and hBoV circulate in PA; this provides evidence of frequent involvement of both viruses in children with clinical signs of acute viral respiratory tract infection, although they mainly appeared as coinfection agents.
Resumo:
Malaria diagnoses has traditionally been made using thick blood smears, but more sensitive and faster techniques are required to process large numbers of samples in clinical and epidemiological studies and in blood donor screening. Here, we evaluated molecular and serological tools to build a screening platform for pooled samples aimed at reducing both the time and the cost of these diagnoses. Positive and negative samples were analysed in individual and pooled experiments using real-time polymerase chain reaction (PCR), nested PCR and an immunochromatographic test. For the individual tests, 46/49 samples were positive by real-time PCR, 46/49 were positive by nested PCR and 32/46 were positive by immunochromatographic test. For the assays performed using pooled samples, 13/15 samples were positive by real-time PCR and nested PCR and 11/15 were positive by immunochromatographic test. These molecular methods demonstrated sensitivity and specificity for both the individual and pooled samples. Due to the advantages of the real-time PCR, such as the fast processing and the closed system, this method should be indicated as the first choice for use in large-scale diagnosis and the nested PCR should be used for species differentiation. However, additional field isolates should be tested to confirm the results achieved using cultured parasites and the serological test should only be adopted as a complementary method for malaria diagnosis.
Resumo:
This study reports the first genetic characterisation of Cryptosporidium isolates in Brazil using real-time polymerase chain reaction (RT-PCR). A total of 1,197 faecal specimens from children and 10 specimens from human immunodeficiency virus-infected patients were collected between 1999-2010 and screened using microscopy. Forty-eight Cryptosporidium oocyst-positive isolates were identified and analysed using a generic TaqMan assay targeting the 18S rRNA to detect Cryptosporidium species and two other TaqMan assays to identify Cryptosporidium hominis and Cryptosporidium parvum. The 18S rRNA assay detected Cryptosporidium species in all 48 of the stool specimens. The C. parvum TaqMan assay correctly identified five/48 stool samples, while 37/48 stool specimens were correctly amplified in the C. hominis TaqMan assay. The results obtained in this study support previous findings showing that C. hominis infections are more prevalent than C. parvum infections in Brazil and they demonstrate that the TaqMan RT-PCR procedure is a simple, fast and valuable tool for the detection and differentiation of Cryptosporidium species.
Resumo:
ELISA in situ can be used to titrate hepatitis A virus (HAV) particles and real-time polymerase chain reaction (RT-PCR) has been shown to be a fast method to quantify the HAV genome. Precise quantification of viral concentration is necessary to distinguish between infectious and non-infectious particles. The purpose of this study was to compare cell culture and RT-PCR quantification results and determine whether HAV genome quantification can be correlated with infectivity. For this purpose, three stocks of undiluted, five-fold diluted and 10-fold diluted HAV were prepared to inoculate cells in a 96-well plate. Monolayers were then incubated for seven, 10 and 14 days and the correlation between the ELISA in situ and RT-PCR results was evaluated. At 10 days post-incubation, the highest viral load was observed in all stocks of HAV via RT-PCR (10(5) copies/mL) (p = 0.0002), while ELISA revealed the highest quantity of particles after 14 days (optical density = 0.24, p < 0.001). At seven days post-infection, there was a significant statistical correlation between the results of the two methods, indicating equivalents titres of particles and HAV genome during this period of infection. The results reported here indicate that the duration of growth of HAV in cell culture must be taken into account to correlate genome quantification with infectivity.
Resumo:
We evaluated the use of a newly described sodC-based real-time-polymerase chain reaction (RT-PCR) assay for detecting Neisseria meningitidis in normally sterile sites, such as cerebrospinal fluid and serum. The sodC-based RT-PCR assay has an advantage over ctrA for detecting nongroupable N. meningitidis isolates, which are commonly present in asymptomatic pharyngeal carriage. However, in our study, sodC-based RT-PCR was 7.5% less sensitive than ctrA. Given the public health impact of possible false-negative results due to the use of the sodC target gene alone, sodC-based RT-PCR for the diagnosis of meningococcal meningitis should be used with caution.
Resumo:
The rickettsia Anaplasma marginale is considered the main agent of bovine anaplasmosis. Due the nonspecific clinical signs of the anaplasmosis, the diagnosis of infection depends of laboratory confirmation. In recent years, molecular diagnostic methods have been used to detect A. marginale in cattle. However, the existence of a large number of assays of different sensitivity and cost makes the choice of an appropriate test difficult. In the present study, a real-time Polymerase Chain Reaction (PCR) based on the msp5 target gene was quantitatively assessed and compared to an end point PCR. Both reactions were subjected to sensitivity and specificity evaluation using plasmid DNA and samples from cattle experimentally infected with A. marginale. A comparative field trial of the tests was carried out using samples of cattle from a stable enzootic area for A. marginale. The real-time PCR showed a higher sensitivity than the end point PCR. This reaction (i.e. real-time PCR) was able to detect one copy of the msp5 gene in 100 ηg of plasmidial DNA, and more than 80% of its results were positive among experimentally infected animals seven days after infection. In addition, based on in silico analysis, the real-time PCR evaluated in the present study appears to be useful for the detection of A. ovis.
Resumo:
Group A Rotavirus (RVA) is one of the most common causes of diarrhea in humans and several animal species. A SYBR-Green Real-Time polymerase chain reaction (PCR) was developed to diagnose RVA from porcine fecal samples, targeting amplification of a 137-bp fragment of nonstructural protein 5 (NSP5) gene using mRNA of bovine NADH-desidrogenase-5 as exogenous internal control. Sixty-five samples were tested (25 tested positive for conventional PCR and genetic sequencing). The overall agreement (kappa) was 0.843, indicating 'very good' concordance between tests, presenting 100% of relative sensitivity (25+ Real Time PCR/25+ Conventional PCR) and 87.5% of relative sensitivity (35- Real Time PCR/40- Conventional PCR). The results also demonstrated high intra- and inter-assay reproducibility (coefficient of variation ≤1.42%); thus, this method proved to be a fast and sensitive approach for the diagnosis of RVA in pigs.
Resumo:
Hereditary hemochromatosis (HH) is a common autosomal disorder of iron metabolism mainly affecting Caucasian populations. Three recurrent disease-associated mutations have been detected in the hemochromatosis gene (HFE): C282Y, H63D, and S65C. Although HH phenotype has been associated with all three mutations, C282Y is considered the most relevant mutation responsible for hemochromatosis. Clinical complications of HH include cirrhosis of the liver, congestive cardiac failure and cardiac arrhythmias, endocrine pancreatic disease, which can be prevented by early diagnosis and treatment. Therefore, a reliable genotyping method is required for presymptomatic diagnosis. We describe the simultaneous detection of the C282Y, H63D and S65C mutations in the hemochromatosis gene by real-time PCR followed by melting curve analysis using fluorescence resonance energy transfer (FRET) probes. The acceptor fluorophore may be replaced by a quencher, increasing multiplex possibilities. Real-time PCR results were compared to the results of sequencing and conventional PCR followed by restriction digestion and detection by agarose gel electrophoresis (PCR-RFLP). Genotypes from 80 individuals obtained both by the conventional PCR-RFLP method and quenched-FRET real-time PCR were in full agreement. Sequencing also confirmed the results obtained by the new method, which proved to be an accurate, rapid and cost-effective diagnostic assay. Our findings demonstrate the usefulness of real-time PCR for the simultaneous detection of mutations in the HFE gene, which allows a reduction of a significant amount of time in sample processing compared to the PCR-RFLP method, eliminates the use of toxic reagents, reduces the risk of contamination in the laboratory, and enables full process automation.
Resumo:
Amplification of the MYCN gene in neuroblastomas is a potent biological marker of highly aggressive tumors, which are invariably fatal unless sound clinical management is applied. To determine the usefulness of semi-quantitative differential PCR (SQ-PCR) for accurate quantification of MYCN gene copy number, we evaluated the analytical performance of this method by comparing the results obtained with it for 101 tumor samples of neuroblastoma to that obtained by absolute and relative real-time PCR. Similar results were obtained for 100 (99%) samples, no significant difference was detected between the median log10 MYCN copy number (1.53 by SQ-PCR versus 1.55 by absolute real-time PCR), and the results of the two assays correlated closely (r = 0.8, Pearson correlation; P < 0.001). In the comparison of SQ-PCR and relative real-time PCR, SQ-PCR versus relative real-time PCR concordant results were found in 100 (99%) samples, no significant difference was found in median log10 MYCN copy number (1.53 by SQ-PCR versus 1.27 by relative real-time PCR), and the results of the two assays correlated closely (r = 0.8, Pearson correlation; P < 0.001). These findings indicate that the performance of SQ-PCR was comparable to that of real-time PCR for the amplification and quantification of MYCN copy number. Thus, SQ-PCR can be reliably used as an alternative assay in laboratories without facilities for real-time PCR.
Resumo:
The increasing presence of products derived from genetically modified (GM) plants in human and animal diets has led to the development of detection methods to distinguish biotechnology-derived foods from conventional ones. The conventional and real-time PCR have been used, respectively, to detect and quantify GM residues in highly processed foods. DNA extraction is a critical step during the analysis process. Some factors such as DNA degradation, matrix effects, and the presence of PCR inhibitors imply that a detection or quantification limit, established for a given method, is restricted to a matrix used during validation and cannot be projected to any other matrix outside the scope of the method. In Brazil, sausage samples were the main class of processed products in which Roundup Ready® (RR) soybean residues were detected. Thus, the validation of methodologies for the detection and quantification of those residues is absolutely necessary. Sausage samples were submitted to two different methods of DNA extraction: modified Wizard and the CTAB method. The yield and quality were compared for both methods. DNA samples were analyzed by conventional and real-time PCR for the detection and quantification of Roundup Ready® soybean in the samples. At least 200 ng of total sausage DNA was necessary for a reliable quantification. Reactions containing DNA amounts below this value led to large variations on the expected GM percentage value. In conventional PCR, the detection limit varied from 1.0 to 500 ng, depending on the GM soybean content in the sample. The precision, performance, and linearity were relatively high indicating that the method used for analysis was satisfactory.
Resumo:
The DNA extraction is a critical step in Genetically Modified Organisms analysis based on real-time PCR. In this study, the CTAB and DNeasy methods provided good quality and quantity of DNA from the texturized soy protein, infant formula, and soy milk samples. Concerning the Certified Reference Material consisting of 5% Roundup Ready® soybean, neither method yielded DNA of good quality. However, the dilution test applied in the CTAB extracts showed no interference of inhibitory substances. The PCR efficiencies of lectin target amplification were not statistically different, and the coefficients of correlation (R²) demonstrated high degree of correlation between the copy numbers and the threshold cycle (Ct) values. ANOVA showed suitable adjustment of the regression and absence of significant linear deviations. The efficiencies of the p35S amplification were not statistically different, and all R² values using DNeasy extracts were above 0.98 with no significant linear deviations. Two out of three R² values using CTAB extracts were lower than 0.98, corresponding to lower degree of correlation, and the lack-of-fit test showed significant linear deviation in one run. The comparative analysis of the Ct values for the p35S and lectin targets demonstrated no statistical significant differences between the analytical curves of each target.
A real-time quantitative assay for hepatitis B DNA virus (HBV) developed to detect all HBV genotypes
Resumo:
Hepatitis B virus (HBV) is a major cause of chronic liver disease worldwide. Besides genotype, quantitative analysis of HBV infection is extensively used for monitoring disease progression and treatment. Affordable viral load monitoring is desirable in resource-limited settings and it has been already shown to be useful in developing countries for other viruses such as Hepatitis C virus (HCV) and HIV. In this paper, we describe the validation of a real-time PCR assay for HBV DNA quantification with TaqMan chemistry and MGB probes. Primers and probes were designed using an alignment of sequences from all HBV genotypes in order to equally amplify all of them. The assay is internally controlled and was standardized with an international HBV panel. Its efficacy was evaluated comparing the results with two other methods: Versant HBV DNA Assay 3.0 (bDNA, Siemens, NY, USA) and another real-time PCR from a reference laboratory. Intra-assay and inter-assay reproducibilities were determined and the mean of CV values obtained were 0.12 and 0.09, respectively. The assay was validated with a broad dynamic range and is efficient for amplifying all HBV genotypes, providing a good option to quantify HBV DNA as a routine procedure, with a cheap and reliable protocol.
Resumo:
We describe a simple method for detection of Plasmodium vivaxand Plasmodium falciparum infection in anophelines using a triplex TaqMan real-time polymerase chain reaction (PCR) assay (18S rRNA). We tested the assay on Anopheles darlingi and Anopheles stephensi colony mosquitoes fed withPlasmodium-infected blood meals and in duplicate on field collected An. darlingi. We compared the real-time PCR results of colony-infected and field collected An. darlingi, separately, to a conventional PCR method. We determined that a cytochromeb-PCR method was only 3.33% as sensitive and 93.38% as specific as our real-time PCR assay with field-collected samples. We demonstrate that this assay is sensitive, specific and reproducible.
Resumo:
A polipose nasossinusal eosinofílica (PNS) é manifestação de uma doença inflamatória crônica na mucosa do nariz e nos seios paranasais caracterizada por infiltração de granulócitos eosinófilos. O fator responsável pela eosinofilia e manutenção dessas células com a perpetuação do processo inflamatório e formação polipóide é objeto constante de estudos. As citocinas como IL5 (interleucina 5) e GM-CSF (fator estimulador de colônia granulócito macrófago) aumentam a sobrevida dos eosinófilos e prolongam a sua presença no tecido polipóide, diminuindo o índice de apoptose eosinofílica. OBJETIVO: Avaliar o efeito da mitomicina C - MMC - por meio de aplicação tópica em pacientes portadores de PNS eosinofílica quanto à presença de IL5 e GM-CSF. CASUÍSTICA E MÉTODOS: Quinze pacientes portadores de PNS eosinofílica foram submetidos à aplicação tópica de MMC na concentração de 0,5mg/ml, 1ml, durante cinco minutos, na cavidade nasal direita, e submetidos à biópsia para RT-PCR 24hs após. O grupo-controle foi a cavidade nasal esquerda. O perfil de citocinas foi analisado para IL5 e GM-CSF. RESULTADOS: A comparação dos resultados de GM-CSF pré e pós-uso de MMC quando usamos o teste t pareado apresenta p=0,041. A comparação para IL5 resulta em p < 0,001. CONCLUSÃO: O uso de MMC em pacientes com PNS mostra redução com significância estatística par GM-CSF e importante significância para IL5.