55 resultados para Sewage pollution


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heavy-metal concentration in sediment is an important parameter for identifying pollution sources and assessing pollution levels in aquatic ecosystems. In this context, the present study aimed at determining concentrations of heavy metals in sediments from the Vitória estuarine system, Brazil. Twenty nine stations were surveyed to assess the spatial distribution of heavy metals. The metals for silt-clay fractions (<63 µm) were analyzed through atomic absorption spectrometry. A discriminant analysis segregated the stations in four groups representing four areas within the estuarine system. The Espírito Santo Bay showed the lowest metal concentrations, while the Vitória harbor canal showed the highest. We concluded that concentrations of heavy metals reflect natural conditions and the contribution of human activities from sewage and industrial effluents. It was not possible to directly associate metal concentrations to specific pollution sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper evaluates the occurrence of nitrate and ammonium in the Barreiras aquifer in the metropolitan area of Belém, Pará State, Brazil. The results show that some wells display ammonium and nitrate concentrations above or close to the limits of water potability regulations. The main cause of the pollution of these waters is related the local disposal of domestic effluents and/or leakage from pipes of old sewage systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sediment samples from the Barigui River in Curitiba, south of Brazil, were evaluated following granulometric composition, organic carbon content, nitrogen, phosphorus and metals such as zinc, lead, chrome, nickel and cadmium. The sediments shown high percentage of phosphorus and nitrogen. Also the elemental organic C:N:P exceed the Redfield ratios possible because the large amount of sewage input into river. The presence of metals is also high, however the metal cadmium has not been found. But the other metals are in greater concentrations and possibly the presence of these metals is given by industrial and domestic sewage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Daily records of hospital admissions due to cardiorespiratory diseases and levels of PM10, SO2, CO, NO, NO2, and O3 were collected from 1999-2004 to evaluate the relationship between air pollution and morbidity in Lisbon. Generalised additive Poisson regression models were adopted, controlling for temperature, humidity, and both short and long-term seasonality. Significant positive associations, lagged by 1 or 2 days, were found between markers of traffic-related pollution (CO and NO2) and cardiocirculatory diseases in all age groups. Increased childhood emergency admissions for respiratory illness were significantly correlated with the 1-day lagged SO2 levels coming from industrial activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pharmaceutical compounds have been detected in sewage treatment plant (STP) effluents, surface waters and, less frequently, in groundwater and drinking water, all over the world. Different sources are responsible for their appearance in the aquatic environment, however, it is widely accepted that the main sources of this type of pollutant are STP effluents. The adverse effects of pharmaceuticals in the environment include aquatic toxicity, development of resistance in pathogenic bacteria, genotoxicity and endocrine disruption. Thus, the discharge of these compounds to the environment in STP effluents should be minimized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring of sewage sludge has proved the presence of many polar anthropogenic pollutants since LC/MS techniques came into routine use. While advanced techniques may improve characterizations, flawed sample processing procedures, however, may disturb or disguise the presence and fate of many target compounds present in this type of complex matrix before analytical process starts. Freeze-drying or oven-drying, in combination with centrifugation or filtration as sample processing techniques were performed followed by visual pattern recognition of target compounds for assessment of pretreatment processes. The results shown that oven-drying affected the sludge characterization, while freeze-drying led to less analytical misinterpretations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this review is presented an innovative technology for use of animal and vegetable waste with high pollution levels in microbial fuel cell (MFC) as an alternative to waste remediation and simultaneously producing electricity and fertilizer for agriculture. A brief history of MFC, the studies about the electron transfer mechanisms, discussion of the biological nanowires in bacteria and the use of chemical mediators or carriers of electrons are explained. The factors influencing the performance of MFCs, the application in waste and sewage treatment and power generation are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrogen peroxide has been used for decades in developed countries as an oxidizing agent in the treatment of water, domestic sewage and industrial effluents. This study evaluated the influence of the concentration of H2O2 and pH on the inactivation of Escherichia coli cells and the disinfection of sewage treated. The results showed that the inactivation rate increased with pH and H2O2. The presence of other contaminants dissolved in the effluent is probably the cause of these differences, because E. coli inactivation in synthetic wastewater was found to be much faster than in the real treated domestic sewage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparative study of elements deposited on tree bark was carried out for urban and periurban areas of two of the most important cities in Argentina. The content of Fe, Mg, Al, Mn, Zn, Pb, Ba, Cr, Hg, Cu, Ni, Cd and Sb was determined by inductively coupled plasma atomic emission spectrometry (ICP-OES) in Morus alba tree bark collected in the cities of Buenos Aires and Mendoza. The main air pollutants detected in the Buenos Aires urban area were Ba, Cr, Cu and Ni and indicate significative difference from the Mendoza urban and periurban areas. Significantly, higher concentrations of Zn, Ba, Cr and Cu were recorded in the periurban area of the city of Buenos Aires than in Mendoza. Bark samples were strongly influenced by dust and show Al, Fe, Mg and other element accumulations that indicate that soil particles were carried out by wind. Elements like Ba and Zn, commonly linked to traffic emissions, showed the highest concentrations in the Buenos Aires metropolitan area, possibly due to more intensive vehicular traffic. Our results indicated that intensity of vehicular traffic and not city structure is responsible for air pollution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Irrigation with domestic sewage effluent (DSE) has been recommended by subsurface dripping, as it can obtain a high rate of irrigation efficiency and faster use of salts in comparison with other irrigation methods. The study aimed at evaluating the area, the length and the effective depth of the root system of sugarcane irrigated with DSE by subsurface drip system and with different irrigation rates at depths of 0.00-0.20, 0.20-0.40, 0.40-0.60 and 0.60-0.80m. The experiment was carried out in the municipality of Piracicaba, in the state of São Paulo (SP), Brazil, in a sugarcane area irrigated with DSE in a completely randomized blocks set up in furrows, with three replications and four treatments, which are: one area without irrigation (AWI) and three irrigated areas meeting 50% (T50%), 100% (T100%) and 200% (T200%) of the crop's water need between each round of irrigation. T100% and T200% provided smaller areas and lengths of roots in the two deepest layers, as compared to AWI and T50%, which stimulated the development of deeper roots due to the water stress. TWI, T100% and T200% presented 80% of the roots up to a depth of 0.40m and T50% treatment presented 76.43% of roots total.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study used statistical methods of quality control to evaluate the performance of a sewage treatment station. The concerned station is located in Cascavel city, Paraná State. The evaluated parameters were hydrogenionic potential, settleable solids, total suspended solids, chemical oxygen demand and biochemical oxygen demand in five days. Statistical analysis was performed through Shewhart control charts and process capability ratio. According to Shewhart charts, only the BOD(5.20) variable was under statistical control. Through capability ratios, we observed that except for pH the sewage treatment station is not capable to produce effluents under characteristics that fulfill specifications or standard launching required by environmental legislation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the productive performance of sunflower plants irrigated with different levels of domestic treated sewage and groundwater well with different doses of nitrogen. It was used randomized blocks design in split-split plots with four replications. In the plots, we evaluated the effect of two types of irrigation water, in the subplots we evaluated the five irrigation levels expressed as 25, 50, 75, 100 and 125% of the Class A pan Evaporation (CAE), and in the sub subplots, we evaluated the effect of four different doses of nitrogen (25, 50, 75 and 100 kg ha-1). The irrigation of sunflower with domestic sewage produced greater yield potential of grain and oil. The use of water from treated wastewater can replace up to 50 kg N ha-1 without affecting productivity. It is recommended for the commercial production of sunflower the use of treated sewage water with irrigation depth relative to 100% of CAE (296.64 mm) and nitrogen of 25 kg ha-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of treated sewage effluent (TSE) combined with the subsurface drip irrigation (SDI) method in agriculture can decrease the costs of agricultural production, in attempts to fertigate crops more efficiently. In this study it was compared the dimensions of the wet bulb formed by the application of TSE and municipal water supply (MWS) in an Oxisoil. We have evaluated the effect of water quality and discharge between drippers used in sugarcane crop. Three trenches were opened and 21 three-rod TDR probes were setup in a mesh and a dripper was buried at 0.30 m, for each constant discharge of 1.0 L h-1and 1.6 L h-1. Comparing results from different wetted soil profiles it was observed that the vertical and horizontal dimensions of the wet bulb are similar for both MWS and TSE, being peculiars according to the discharges used and volume applied. Regardless the water quality, an increase of 60% in discharge decreased the deepest infiltration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several aspects of nutrient cycling were studied at two sites of Atlantic Forest, in São Paulo State, Southeast Brazil (23o46’ S; 46o18’ W), which exhibited different degrees of forest structure decline caused by the air pollution emitted by the industrial complex of Cubatão, being referred here as the most and least affected sites (MAS and LAS, respectively). These investigations were developed during 1984 - 1986, a period in which the most severe negative effects of air pollution could be observed. Concentrations and amounts of N, P, K, Ca, Mg and S in four ecosystem compartments (leaves, litter layer, soil and roots) and in rainfall, throughfall and litterfall are briefly presented. At each site, the content of mineral elements generally decreased from leaves to litterfall and litter layer on the forest floor. Soil surface layer (0 - 5 cm) in both sites was the richest in mineral elements. Soil fertility was greater at LAS. In general, nutrient amounts remaining in the compartments and cycling through the ecosystem were greater at LAS as well, which could be due to the higher complexity of the forest structure at this site. Rainfall contributed more to soil inputs of K, Ca, Mg and S than litterfall at both sites. The nutrient residence times in the litter layer were higher and the index of nutrient use efficiency was lower at the most affected site. It was concluded that nutrient cycling was disturbed by air pollution at both sites, but to a greater extent at MAS. The main consequences of the air pollution stress were detected in the flux of nutrients through litterfall and in the litter layer on the forest floor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing use of alcohol as an alternative fuel to gasoline or diesel can increase emission of formaldehyde, an organic gas that is irritant to the mucous membranes. The respiratory system is the major target of air pollutants and its major defense mechanism depends on the continuous activity of the cilia and the resulting constant transportation of mucous secretion. The present study was designed to evaluate the effects of formaldehyde on the ciliated epithelium through a relative large dose range around the threshold limit value adopted by the Brazilian legislation, namely 1.6 ppm (1.25 to 5 ppm). For this purpose, the isolated frog palate preparation was used as the target of toxic injury. Four groups of frog palates were exposed to diluted Ringer solution (control, N = 8) and formaldehyde diluted in Ringer solution at three different concentrations (1.25, 2.5 and 5.0 ppm, N = 10 for each group). Mucociliary clearance and ciliary beat frequency decreased significantly in contact with formaldehyde at the concentrations of 2.5 and 5.0 ppm after 60 min of exposure (P<0.05). We conclude that relatively low concentrations of formaldehyde, which is even below the Brazilian threshold limit value, are sufficient to cause short-term mucociliary impairment.