38 resultados para Reliability assessments
Resumo:
The objective of the present study was to determine the reliability of the Brazilian version of the Composite International Diagnostic Interview 2.1 (CIDI 2.1) in clinical psychiatry. The CIDI 2.1 was translated into Portuguese using WHO guidelines and reliability was studied using the inter-rater reliability method. The study sample consisted of 186 subjects from psychiatric hospitals and clinics, primary care centers and community services. The interviewers consisted of a group of 13 lay and three non-lay interviewers submitted to the CIDI training. The average interview time was 2 h and 30 min. General reliability ranged from kappa 0.50 to 1. For lifetime diagnoses the reliability ranged from kappa 0.77 (Bipolar Affective Disorder) to 1 (Substance-Related Disorder, Alcohol-Related Disorder, Eating Disorders). Previous year reliability ranged from kappa 0.66 (Obsessive-Compulsive Disorder) to 1 (Dissociative Disorders, Maniac Disorders, Eating Disorders). The poorest reliability rate was found for Mild Depressive Episode (kappa = 0.50) during the previous year. Training proved to be a fundamental factor for maintaining good reliability. Technical knowledge of the questionnaire compensated for the lack of psychiatric knowledge of the lay personnel. Inter-rater reliability was good to excellent for persons in psychiatric practice.
Resumo:
The objective of the present study was to translate, adapt and validate a Brazilian Portuguese version of the Disabilities of the Arm, Shoulder and Hand (DASH) Questionnaire. The study was carried out in two steps. The first was to translate the DASH into Portuguese and to perform cultural adaptation and the second involved the determination of the reliability and validity of the DASH for the Brazilian population. For this purpose, 65 rheumatoid arthritis patients of either sex (according to the classification criteria of the American College of Rheumatology), ranging in age from 18 to 60 years and presenting no other diseases involving the upper limbs, were interviewed. The patients were selected consecutively at the rheumatology outpatient clinic of UNIFESP. The following results were obtained: in the first step (translation and cultural adaptation), all patients answered the questions. In the second step, Spearman's correlation coefficients for interobserver evaluation ranged from 0.762 to 0.995, values considered to be highly reliable. In addition, intraclass correlation coefficients ranged from 0.97 to 0.99, also highly reliable values. Spearman's correlation coefficients and the intraclass correlation coefficients obtained during intra-observer evaluation ranged from 0.731 to 0.937 and from 0.90 to 0.96, respectively, being highly reliable values. The Ritchie Index showed a weak correlation with Brazilian DASH scores, while the visual analog scale of pain showed a good correlation with DASH score. We conclude that the Portuguese version of the DASH is a reliable instrument.
Resumo:
The reliability and validity of a Portuguese version of the Young Mania Rating Scale were evaluated. The original scale was translated into and adapted to Portuguese by the authors. Definitions of clinical manifestations, a semi-structured anchored interview and more explicit rating criteria were added to the scale. Fifty-five adult subjects, aged 18 to 60 years, with a diagnosis of Current Manic Episode according to DSM-III-R criteria were assessed using the Young Mania Rating Scale as well as the Brief Psychiatric Rating Scale in two sessions held at intervals from 7 to 10 days. Good reliability ratings were obtained, with intra-class correlation coefficient of 0.97 for total scores, and levels of agreement above 0.80 (P < 0.001) for all individual items. Internal consistency analysis resulted in an alpha = 0.67 for the scale as a whole, and an alpha = 0.72 for each standardized item (P < 0.001). For the concurrent validity, a correlation of 0.78 was obtained by the Pearson coefficient between the total scores of the Young Mania Rating Scale and Brief Psychiatric Rating Scale. The results are similar to those reported for the English version, indicating that the Portuguese version of the scale constitutes a reliable and valid instrument for the assessment of manic patients.
Resumo:
In a cross-sectional study conducted four years ago to assess the validity of the Brazilian version of the Eating Attitudes Test-26 (EAT-26) for the identification of abnormal eating behaviors in a population of young females in Southern Brazil, 56 women presented abnormal eating behavior as indicated by the EAT-26 and the Edinburgh Bulimic Investigation Test. They were each matched for age and neighborhood to two normal controls (N = 112) and were re-assessed four years later with the two screening questionnaires plus the Composite International Diagnostic Interview (CIDI). The EAT results were then compared to diagnoses originating from the CIDI. To evaluate the temporal stability of the two screening questionnaires, a test-retest design was applied to estimate kappa coefficients for individual items. Given the prevalence of eating disorders of 6.2%, the CIDI psychiatry interview was applied to 161 women. Of these, 0.6% exhibited anorexia nervosa and 5.6%, bulimia nervosa (10 positive cases). The validity coefficients of the EAT were: 40% sensitivity, 84% specificity, and 14% positive predictive value. Cronbach's coefficient was 0.75. For each EAT item, the kappa index was not higher than 0.344 and the correlation coefficient was lower than 0.488. We conclude that the EAT-26 exhibited low validity coefficients for sensitivity and positive predictive value, and showed a poor temporal stability. It is reasonable to assume that these results were not influenced by the low prevalence of eating disorders in the community. Thus, the results cast doubts on the ability of the EAT-26 test to identify cases of abnormal eating behaviors in this population.
Resumo:
This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.
Resumo:
Studies on the assessment of heart rate variability threshold (HRVT) during walking are scarce. We determined the reliability and validity of HRVT assessment during the incremental shuttle walk test (ISWT) in healthy subjects. Thirty-one participants aged 57 ± 9 years (17 females) performed 3 ISWTs. During the 1st and 2nd ISWTs, instantaneous heart rate variability was calculated every 30 s and HRVT was measured. Walking velocity at HRVT in these tests (WV-HRVT1 and WV-HRVT2) was registered. During the 3rd ISWT, physiological responses were assessed. The ventilatory equivalents were used to determine ventilatory threshold (VT) and the WV at VT (WV-VT) was recorded. The difference between WV-HRVT1 and WV-HRVT2 was not statistically significant (median and interquartile range = 4.8; 4.8 to 5.4 vs4.8; 4.2 to 5.4 km/h); the correlation between WV-HRVT1 and WV-HRVT2 was significant (r = 0.84); the intraclass correlation coefficient was high (0.92; 0.82 to 0.96), and the agreement was acceptable (-0.08 km/h; -0.92 to 0.87). The difference between WV-VT and WV-HRVT2 was not statistically significant (4.8; 4.8 to 5.4 vs 4.8; 4.2 to 5.4 km/h) and the agreement was acceptable (0.04 km/h; -1.28 to 1.36). HRVT assessment during walking is a reliable measure and permits the estimation of VT in adults. We suggest the use of the ISWT for the assessment of exercise capacity in middle-aged and older adults.
Resumo:
The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.
Resumo:
Knowledge seems to need the admixture of de facto reliability and epistemic responsibility. But philosophers have had a hard time in attempting to combine them in order to achieve a satisfactory account of knowledge. In this paper I attempt to find a solution by capitalizing on the real and ubiquitous human phenomenon that is the social dispersal of epistemic labour through time. More precisely, the central objective of the paper is to deliver a novel and plausible social account of knowledge-relevant responsibility and to consider the merits of the proposed combination of reliability and responsibility with respect to certain cases of unreflective epistemic subjects.