53 resultados para Real-time quantitative PCR


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Group A Rotavirus (RVA) is one of the most common causes of diarrhea in humans and several animal species. A SYBR-Green Real-Time polymerase chain reaction (PCR) was developed to diagnose RVA from porcine fecal samples, targeting amplification of a 137-bp fragment of nonstructural protein 5 (NSP5) gene using mRNA of bovine NADH-desidrogenase-5 as exogenous internal control. Sixty-five samples were tested (25 tested positive for conventional PCR and genetic sequencing). The overall agreement (kappa) was 0.843, indicating 'very good' concordance between tests, presenting 100% of relative sensitivity (25+ Real Time PCR/25+ Conventional PCR) and 87.5% of relative sensitivity (35- Real Time PCR/40- Conventional PCR). The results also demonstrated high intra- and inter-assay reproducibility (coefficient of variation ≤1.42%); thus, this method proved to be a fast and sensitive approach for the diagnosis of RVA in pigs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hereditary hemochromatosis (HH) is a common autosomal disorder of iron metabolism mainly affecting Caucasian populations. Three recurrent disease-associated mutations have been detected in the hemochromatosis gene (HFE): C282Y, H63D, and S65C. Although HH phenotype has been associated with all three mutations, C282Y is considered the most relevant mutation responsible for hemochromatosis. Clinical complications of HH include cirrhosis of the liver, congestive cardiac failure and cardiac arrhythmias, endocrine pancreatic disease, which can be prevented by early diagnosis and treatment. Therefore, a reliable genotyping method is required for presymptomatic diagnosis. We describe the simultaneous detection of the C282Y, H63D and S65C mutations in the hemochromatosis gene by real-time PCR followed by melting curve analysis using fluorescence resonance energy transfer (FRET) probes. The acceptor fluorophore may be replaced by a quencher, increasing multiplex possibilities. Real-time PCR results were compared to the results of sequencing and conventional PCR followed by restriction digestion and detection by agarose gel electrophoresis (PCR-RFLP). Genotypes from 80 individuals obtained both by the conventional PCR-RFLP method and quenched-FRET real-time PCR were in full agreement. Sequencing also confirmed the results obtained by the new method, which proved to be an accurate, rapid and cost-effective diagnostic assay. Our findings demonstrate the usefulness of real-time PCR for the simultaneous detection of mutations in the HFE gene, which allows a reduction of a significant amount of time in sample processing compared to the PCR-RFLP method, eliminates the use of toxic reagents, reduces the risk of contamination in the laboratory, and enables full process automation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The DNA extraction is a critical step in Genetically Modified Organisms analysis based on real-time PCR. In this study, the CTAB and DNeasy methods provided good quality and quantity of DNA from the texturized soy protein, infant formula, and soy milk samples. Concerning the Certified Reference Material consisting of 5% Roundup Ready® soybean, neither method yielded DNA of good quality. However, the dilution test applied in the CTAB extracts showed no interference of inhibitory substances. The PCR efficiencies of lectin target amplification were not statistically different, and the coefficients of correlation (R²) demonstrated high degree of correlation between the copy numbers and the threshold cycle (Ct) values. ANOVA showed suitable adjustment of the regression and absence of significant linear deviations. The efficiencies of the p35S amplification were not statistically different, and all R² values using DNeasy extracts were above 0.98 with no significant linear deviations. Two out of three R² values using CTAB extracts were lower than 0.98, corresponding to lower degree of correlation, and the lack-of-fit test showed significant linear deviation in one run. The comparative analysis of the Ct values for the p35S and lectin targets demonstrated no statistical significant differences between the analytical curves of each target.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study reports the first genetic characterisation of Cryptosporidium isolates in Brazil using real-time polymerase chain reaction (RT-PCR). A total of 1,197 faecal specimens from children and 10 specimens from human immunodeficiency virus-infected patients were collected between 1999-2010 and screened using microscopy. Forty-eight Cryptosporidium oocyst-positive isolates were identified and analysed using a generic TaqMan assay targeting the 18S rRNA to detect Cryptosporidium species and two other TaqMan assays to identify Cryptosporidium hominis and Cryptosporidium parvum. The 18S rRNA assay detected Cryptosporidium species in all 48 of the stool specimens. The C. parvum TaqMan assay correctly identified five/48 stool samples, while 37/48 stool specimens were correctly amplified in the C. hominis TaqMan assay. The results obtained in this study support previous findings showing that C. hominis infections are more prevalent than C. parvum infections in Brazil and they demonstrate that the TaqMan RT-PCR procedure is a simple, fast and valuable tool for the detection and differentiation of Cryptosporidium species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ELISA in situ can be used to titrate hepatitis A virus (HAV) particles and real-time polymerase chain reaction (RT-PCR) has been shown to be a fast method to quantify the HAV genome. Precise quantification of viral concentration is necessary to distinguish between infectious and non-infectious particles. The purpose of this study was to compare cell culture and RT-PCR quantification results and determine whether HAV genome quantification can be correlated with infectivity. For this purpose, three stocks of undiluted, five-fold diluted and 10-fold diluted HAV were prepared to inoculate cells in a 96-well plate. Monolayers were then incubated for seven, 10 and 14 days and the correlation between the ELISA in situ and RT-PCR results was evaluated. At 10 days post-incubation, the highest viral load was observed in all stocks of HAV via RT-PCR (10(5) copies/mL) (p = 0.0002), while ELISA revealed the highest quantity of particles after 14 days (optical density = 0.24, p < 0.001). At seven days post-infection, there was a significant statistical correlation between the results of the two methods, indicating equivalents titres of particles and HAV genome during this period of infection. The results reported here indicate that the duration of growth of HAV in cell culture must be taken into account to correlate genome quantification with infectivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated the use of a newly described sodC-based real-time-polymerase chain reaction (RT-PCR) assay for detecting Neisseria meningitidis in normally sterile sites, such as cerebrospinal fluid and serum. The sodC-based RT-PCR assay has an advantage over ctrA for detecting nongroupable N. meningitidis isolates, which are commonly present in asymptomatic pharyngeal carriage. However, in our study, sodC-based RT-PCR was 7.5% less sensitive than ctrA. Given the public health impact of possible false-negative results due to the use of the sodC target gene alone, sodC-based RT-PCR for the diagnosis of meningococcal meningitis should be used with caution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Human herpesvirus 6 (HHV-6) may cause severe complications after haematopoietic stem cell transplantation (HSCT). Monitoring this virus and providing precise, rapid and early diagnosis of related clinical diseases, constitute essential measures to improve outcomes. A prospective survey on the incidence and clinical features of HHV-6 infections after HSCT has not yet been conducted in Brazilian patients and the impact of this infection on HSCT outcome remains unclear. A rapid test based on real-time quantitative polymerase chain reaction (qPCR) has been optimised to screen and quantify clinical samples for HHV-6. The detection step was based on reaction with TaqMan® hydrolysis probes. A set of previously described primers and probes have been tested to evaluate efficiency, sensitivity and reproducibility. The target efficiency range was 91.4% with linearity ranging from 10-106 copies/reaction and a limit of detection of five copies/reaction or 250 copies/mL of plasma. The qPCR assay developed in the present study was simple, rapid and sensitive, allowing the detection of a wide range of HHV-6 loads. In conclusion, this test may be useful as a practical tool to help elucidate the clinical relevance of HHV-6 infection and reactivation in different scenarios and to determine the need for surveillance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a simple method for detection of Plasmodium vivaxand Plasmodium falciparum infection in anophelines using a triplex TaqMan real-time polymerase chain reaction (PCR) assay (18S rRNA). We tested the assay on Anopheles darlingi and Anopheles stephensi colony mosquitoes fed withPlasmodium-infected blood meals and in duplicate on field collected An. darlingi. We compared the real-time PCR results of colony-infected and field collected An. darlingi, separately, to a conventional PCR method. We determined that a cytochromeb-PCR method was only 3.33% as sensitive and 93.38% as specific as our real-time PCR assay with field-collected samples. We demonstrate that this assay is sensitive, specific and reproducible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present study was to develop a quantitative method to evaluate laser-induced choroidal neovascularization (CNV) in a rat model using Heidelberg Retina Angiograph 2 (HRA2) imaging. The expression of two heparan sulfate proteoglycans (HSPG) related to inflammation and angiogenesis was also investigated. CNV lesions were induced with argon laser in 21 heterozygous Zucker rats and after three weeks a fluorescein angiogram and autofluorescence exams were performed using HRA2. The area and greatest linear dimension were measured by two observers not aware of the protocol. Bland-Altman plots showed agreement between the observers, suggesting that the technique was reproducible. After fluorescein angiogram, HSPG (perlecan and syndecan-4) were analyzed by real-time RT-PCR and immunohistochemistry. There was a significant increase in the expression of perlecan and syndecan-4 (P < 0.0001) in retinas bearing CNV lesions compared to control retinas. The expression of these two HSPG increased with increasing CNV area. Immunohistochemistry demonstrated that the rat retina damaged with laser shots presented increased expression of perlecan and syndecan-4. Moreover, we observed that the overexpression occurred in the outer layer of the retina, which is related to choroidal damage. It was possible to develop a standardized quantitative method to evaluate CNV in a rat model using HRA2. In addition, we presented data indicating that the expression of HSPG parallels the area of CNV lesion. The understanding of these events offers opportunities for studies of new therapeutic interventions targeting these HSPG.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high incidence of cytomegalovirus (CMV) infections is observed in Brazil. These viruses are causatives of significant morbidity and mortality among patients with advanced human immunodeficiency virus (HIV) infection. This work, shows the application of a PCR on determination of CMV load in the buffy coat and plasma. We analyzed the samples of 247 HIV infected patients in order to diagnose CMV infection and disease. We developed a semi-quantitative PCR that amplifies part of the glycoprotein B (gB) gene of CMV. The semi-quantitative PCR was carried out only in positive clinical samples in a qualitative PCR confirmed by a nested-PCR. CD4 lymphocyte count, HIV viral load and CMV disease symptom were correlated with CMV load. CMV genome was detected in the buffy coat of 82 of 237 (34.6%) patients, in 10 of these the CMV load was determined varying between 928 and 332 880 viral copies/mug DNA. None of these 237 patients developed any suggestive manifestation of CMV disease. For the other 10 HIV infected patients selected based on the suspicion of CMV disease, CMV genome was detected in only one case. This patient presented a high CMV load, 8 000 000 copies/mug DNA, and developed a disseminated form of CMV disease including hepatitis and retinitis. Our results were greatly influenced by the impact of the highly active antiretroviral therapy that reduced incidence of CMV viremia and occurrence of CMV disease in the HIV infected patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study aimed at standardizing a real-time quantitative polymerase chain reaction assay to evaluate the presence of GBV-C/HGV RNA. A "TaqMan" assay using primers and probe derived from the 5¢ NCR region was developed and validated. Two hundred and fifty-three plasma samples from HIV-infected women were tested for GBV-C viremia and antibody against the envelope protein 2. GBV-C RNA was detected in 22.5% of the patients whereas the antibody was identified in 25.3% of the cohort. Detection of viral RNA and of antibodies was mutually exclusive. Viral loads showed a mean of 1,777 arbitrary units / mL, being 1.1 and 13,625 arbitrary units / mL respectively the lowest and highest values measured. We conclude that the real-time quantitative polymerase chain reaction method developed is appropriate for the investigation of GBV-C RNA since it was shown to be highly specific and sensitive, as well as requiring few steps, preventing contamination and providing additional information as to the relative viremia of carriers, a parameter that must be included in studies evaluating the co-factors influencing the clinical outcome of HIV/AIDS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Occult hepatitis B infection (OBI) is considered to be one of the major risks for patients suffering from end-stage renal disease (ESRD) on regular hemodialysis (HD) and patients with chronic hepatitis C virus (HCV) infection. This study compared the prevalence of OBI among these two high-risk groups in the Suez Canal region, Northeastern Egypt, to obtain a better national overview of the magnitude of OBI in this region. METHODS: Serum samples were collected from 165 HD patients and 210 chronic HCV-infected patients. Anti-HCV antibody, hepatitis B surface antigen (HBsAg), total hepatitis B core (anti-HBc) antibody, and hepatitis B surface antibody (anti-HBs) were detected by enzyme-linked immunosorbent assay (ELISA). HCV RNA was detected using a quantitative real-time RT-PCR assay, and HBV was detected using a nested PCR. RESULTS: All patients were negative for HBsAg. A total of 49.1% and 25.2% of the patients in the HD and HCV groups, respectively, were anti-HBc-positive. In addition, more anti-HBs-positive patients were detected in the HD group compared to the HCV group (52.1% and 11.4%, respectively). Three cases were positive for HBV DNA in the HD group, while eighteen positive cases were detected in the HCV group. Both study groups showed significant differences in serum alanine aminotransferase (ALT) and aspartate aminotransferase (AST) level as well as anti-HBc, anti-HBs and HBV-DNA positivity. CONCLUSIONS: OBI was more prevalent among chronic HCV patients than HD patients in the Suez Canal region, Egypt, with rates of 8.5% and 1.8%, respectively. However, more precise assessment of this infection requires regular patient follow-up using HBV DNA detection methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT INTRODUCTION: Human metapneumovirus (hMPV) is an emergent human respiratory pathogen. This study aimed to evaluate the performance of direct immunofluorescence (DIF) to detect hMPV in a clinical laboratory setting. METHODS: Nasopharyngeal aspirate samples (448) of children and adults with respiratory illness were used to detect hMPV by using DIF and real time quantitative reverse transcription-polymerase chain reaction (qRT-PCR) assays. RESULTS: In all, 36 (8%) samples were positive by DIF and 94 (21%) were positive by qRT-PCR. Direct immunofluorescence specificity was 99% and sensitivity was 38%. CONCLUSIONS: DIF is not very sensitive under clinical laboratory settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Niterói, state of Rio de Janeiro, dengue virus type 4 (DENV-4) was isolated for the first time in March 2011. We analysed the laboratory findings of the first cases and evaluated the use of molecular techniques for the detection of DENV-4 in Aedes aegypti that were field-caught. Conventional reverse transcriptase-polymerase chain reaction (RT-PCR) and SimplexaTM Dengue real-time RT-PCR confirmed DENV-4 infection in all cases. Additionally, DENV-4 was confirmed in a female Ae. aegypti with 1.08 x 10³ copies/mL of virus, as determined by quantitative real-time RT-PCR. This is the first time the SimplexaTM Dengue real-time assay has been used for the classification of cases of infection and for entomological investigations. The use of these molecular techniques was shown to be important for the surveillance of dengue in humans and vectors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to standardise an in-house real-time polymerase chain reaction (rtPCR) to allow quantification of hepatitis B virus (HBV) DNA in serum or plasma samples, and to compare this method with two commercial assays, the Cobas Amplicor HBV monitor and the Cobas AmpliPrep/Cobas TaqMan HBV test. Samples from 397 patients from the state of São Paulo were analysed by all three methods. Fifty-two samples were from patients who were human immunodeficiency virus and hepatitis C virus positive, but HBV negative. Genotypes were characterised, and the viral load was measure in each sample. The in-house rtPCR showed an excellent success rate compared with commercial tests; inter-assay and intra-assay coefficients correlated with commercial tests (r = 0.96 and r = 0.913, p < 0.001) and the in-house test showed no genotype-dependent differences in detection and quantification rates. The in-house assay tested in this study could be used for screening and quantifying HBV DNA in order to monitor patients during therapy.