38 resultados para Potentiometric titration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In potentiometric titrations of metal cations with EDTA the Hg/HgY2- system is usually used to detect the end point. However, the use of mercury has been discouraged in analytical procedures due to its toxicity. In this work the Cu/CuY2- system was used as indicator electrode for potentiometric titrations of some metal cations with EDTA. The solutions of Cu2+, Cd2+, Mn2+, Co2+ and Zn2+ were titrated with Na2EDTA solution in the presence of a small concentration of the CuY2- complex using a copper wire as indicator electrode. The potentiometric titrations with the Cu/CuY2- system showed good correlation when compared with an Hg/HgY2- system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, precise, rapid and low-cost potentiometric method for captopril determination in pure form and in pharmaceutical preparations is proposed. Captopril present in tablets containing known quantity of drug was potentiometrically titrated in aqueous solution with NaOH using a glass pH electrode, coupled to an autotitrator. No interferences were observed in the presence of common components of the tablets as lactose, microcrystalline cellulose, croscarmellose sodium, starch and magnesium stearate. The analytical results obtained by applying the proposed method compared very favorably with those obtained by the United States Pharmacopoeia Standard procedure. Recovery of captopril from various tablet dosage formulations range from 98.0 to 102.0%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A photometric flow titration based on the redox reaction between KMnO4 and minoxidil is described. The best titration results were observed at 3.20 x 10-4 mol L-1 KMnO4 and 1.00 x 10-3 mol L-1 minoxidil, using the minoxidil solutions as titrant. The flow rate was fixed at 17 mL min-1 and the titrant was added to the system in aliquots of 500 µL, the color changes were monitored at 550 nm. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.6 to 102.8 % were observed depending on the sample. Comparison with the chromatographic procedure reveled relative errors of 3.5 - 4.0 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The precise nature of the reaction between nitric acid and sodium ortho-vanadate solutions has been studied by means of electrometric techniques involving potentiometric and conductometric titrations. The well defined inflections and breaks in the titration curves confirm the existence of the anions, pyro-V2O7(4-), meta-VO3- and poly-H2V10O28(4-) corresponding to the ratios of VO4(3-):H+ as 1:1, 1:2 and 1:2.6 in the neighborhood of pH 10.5, 7.4 and 3.6, respectively. The interaction of cerium(III) nitrate with sodium vanadate solutions, at specific pH levels 12.4, 10.5, 7.4 and 3.6 was also studied by potentiometric and conductometric titrations between the reactants. The end-points obtained from the sharp inflections in the titration curves provide definite evidence for the formation and precipitation of cerium ortho-Ce2O3.V2O5, pyro-2Ce2O3.3V2O5 and meta-Ce2O3.3V2O5 vanadates in the neighborhood of pH 7.4, 6.2 and 4.8, respectively. Analytical investigations on the precipitates formed confirm the results of the electrometric study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of parameters expressed in terms of carbonic species such as Alkalinity and Acidity of saline waters do not analyze the influence of external parameters to the titration such as Total free and associated Carbonic Species Concentration, activity coefficient, ion pairing formation and Residual Liquid Junction Potential in pH measurements. This paper shows the development of F5BC titration function based on the titrations developed by Gran (1952) for the carbonate system of natural waters. For practical use, samples of saline waters from Pocinhos reservoir in Paraiba were submitted to titration and linear regression analysis. Results showed that F5BC involves F1x and F2x Gran functions determination, respectively, for Alkalinity and Acidity calculations without knowing "a priori" the endpoint of the titration. F5BC also allows the determination of the First and Second Apparent Dissociation Constant of the carbonate system of saline and high ionic strength waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stabilizing free energy of ß-trypsin was determined by hydrogen ion titration. In the pH range from 3.0 to 7.0, the change in free energy difference for the stabilization of the native protein relative to the unfolded one (D D G0 titration) was 9.51 ± 0.06 kcal/mol. An isoelectric point of 10.0 was determined, allowing us to calculate the Tanford and Kirkwood electrostatic factor w. This factor presented a nonlinear behavior and indicated more than one type of titratable carboxyl groups in ß-trypsin. In fact, one class of carboxyl group with a pK = 3.91 ± 0.01 and another one with a pK = 4.63 ± 0.03 were also found by hydrogen ion titration of the protein in the folded state

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatitis A virus (HAV) replicates relatively slowly in cell culture without a cytopathic effect, a fact that limits the use of tissue culture assays. The radioimmunofocus assay is the standard method for HAV titration, although it is labor intensive and requires the use of radioisotopes. A simple, rapid and objective infectivity assay based on an in situ enzyme immunoassay (EIA) is described here for a Brazilian cell culture-adapted HAV strain (HAF-203). The assay uses a peroxidase-labeled polyclonal antibody to fixed monolayers as an indicator of infection. EIA may be completed within 7 days using serial 5-fold dilutions of the virus, yielding a titer of 5.024 log 50% tissue culture infective dose (TCID50)/ml for HAF-203. This technique had a detection limit of 1.1 log TCID50/ml and the specificity was demonstrated by detecting no reaction on the columns of uninfected wells. The reproducibility (with intra- and inter-assay coefficients of variation ranging from 1.9 to 3.8% and from 3.5 to 9.9%, respectively) and quantitation of the assay were demonstrated by close agreement in virus infectivity titers among different assays of the same amount of virus and between assays of different amounts of virus. Furthermore, this assay does not require the use of radiolabeled antibodies. We describe here an efficient EIA that is highly reproducible and that could be used to monitor HAV growth in cell culture and to determine the quantity of HAV antigen needed for diagnostic assays. This is the first report of the infectious titer of the Brazilian cell culture-adapted HAV strain (HAF-203).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectinases are enzymes that degrade pectic substances and are widely used in juice and fruit beverages to improve the quality of the process. The objective of this study was to determine the optimum pH and temperature of two samples of commercial pectinases and propose an alternative procedure to determine the residual activity comparing the data with those of the traditional procedure. The pectin methylesterase (PME) activity in Pectinex 100 L Plus and Panzyn Clears was determined by potentiometry. The reaction consisted of 5.00 mg.mL-1 apple pectin, 0.100 mol.L-1 NaCl, and 50 µL enzyme to a total volume of 30 mL. The pectin reaction in the presence of PME in all experiments revealed a first order kinetics. The PME in the two enzyme preparations showed higher activity at pH 4.0 to 4.5 and temperature of 45 ºC. From the results of both procedures ΔV NaOH/Δt and ΔpH/Δt, it was concluded that the inactivation of PME occurred at 75 ºC. The results obtained from the ratio ΔpH/Δt showed good correlation with those obtained from the ratio ΔV NaOH/Δt. In the reaction accompanied by the ratio ΔpH/Δt, the release of H3O+ occurred in the real time reaction.