114 resultados para Positive Predictive-value
Resumo:
Entamoeba histolytica actually comprises two genetically distinct but morphologically indistinguishable species. E. histolytica can cause invasive intestinal and extra intestinal disease, while E. dispar cannot. Identification and differentiation of E. dispar and E. histolytica in stool sample by microscopy is imprecise. Several weeks of culture and isoenzyme analysis are required to differentiate E. histolytica from E. dispar. In this study, we have used an enzyme-linked immunosorbent assay (ELISA) for detection of E. histolytica/E.dispar and compared it with microscopy. Eighty-eight samples were evaluated, trichrome staining was positive in 20.4% (18) and ELISA was positive in 29.5% (26). Both tests were positive in 14 (15.9%) samples, 4 (4.5%) only with direct microscopy, and 12 (13.6%) only with ELISA. Both tests were negative in 58 (65.9%) samples. Microscopy has low sensitivity and high specificity, low negative predictive value and high positive predictive value in comparison with ELISA. E. histolytica/E. dispar antigen detection ELISA tests are inexpensive compared to the specific tests, yield objective results and do not require experienced microscopists and can therefore be recommended for screening of stools worldwide and the results can be taken for treatment that are fitting with its clinic.
Resumo:
The clinical value of an in-house cytomegalovirus nested polymerase chain reaction (CMV-PCR) and a commercial molecular assay hybrid capture CMV DNA assay (HCA) was evaluated in monitoring a group of renal transplant patients for six months follow up. In this study, the sensitivity, specificity, positive predictive value, and negative predictive value of nested CMV DNA PCR assay and HCA at the beginning of the study were 70, 42.9, 46.7, 66.7, and 60, 78.6, 66.7, and 73.3% respectively. After six months, they were 80, 66.7, 80, 66.7 for CMV PCR and 73.3, 88.9, 91.7, 66.7% for HCA respectively. These results indicate that in monitoring and predicting CMV infections in renal transplant recipients, not only qualitative but also quantitative assays must be used together in order to decide the preemptive strategies.
Resumo:
In Nigeria, schistosomiasis, caused predominantly by the species Schistosoma haematobium, is highly endemic in resource-poor communities. We performed a school-based survey in two rural communities in Osun State (Southwestern Nigeria) and assessed macrohaematuria, microhaematuria and proteinuria as indirect indicators for the presence of disease. Urine samples were inspected macroscopically for haematuria and screened for microhaematuria and proteinuria using urine reagent strips. The microscopic examination of schistosome eggs was used as the gold standard for diagnosis. In total, 447 schoolchildren were included in this study and had a 51% prevalence of urinary schistosomiasis. The sensitivity of microhaematuria (68%) and proteinuria (53%) for infection with S. haematobium was relatively low. In patients with a heavy infection (>500 eggs/10 mL), the sensitivity of microhaematuria was high (95%). When the presence of macrohaematuria and the concomitant presence of microhaematuria and proteinuria were combined, it revealed a sensitivity of 63%, a specificity of 93% and a positive predictive value of 91%. Macrohaematuria also showed high specificity (96%) and a positive predictive value of 92%, while sensitivity was < 50%. These data show that combining urine reagent strip tests (presence of proteinuria and microhaematuria) and information on macrohaematuria increased the accuracy of the rapid diagnosis of urinary schistosomiasis in an endemic rural West African setting. This simple approach can be used to increase the quality of monitoring of schistosomiasis in schoolchildren.
Resumo:
Toxoplasma gondii causes posterior uveitis and the specific diagnosis is based on clinical criteria. The presence of anti-T. gondii secretory IgA (sIgA) antibodies in patients' tears has been reported and an association was found between ocular toxoplasmosis and the anti-T. gondii sIgA isotype in Brazilian patients. The purpose of this study was to provide an objective validation of the published ELISA test for determining the presence of anti-T. gondii sIgA in the tears of individuals with ocular toxoplasmosis. Tears from 156 patients with active posterior uveitis were analysed; 82 of them presented characteristics of ocular toxoplasmosis (standard lesion) and 74 patients presented uveitis due to other aetiologies. Cases of active posterior uveitis were considered standard when a new inflammatory focus satellite to old retinochoroidal scars was observed. The determination of anti-T. gondii sIgA was made using an ELISA test with crude tachyzoite antigenic extracts. Tears were collected without previous stimulation. Detection of sIgA showed 65.9% sensitivity (95% CI = 54.5-74.4), 71.6% specificity (95% CI = 59.8-81.2), a positive predictive value of 72% (95% CI = 60.3-81.5) and a negative predictive value of 65.4% (95% CI = 54.0-75.4). sIgA reactivity was higher in the tears of patients with active posterior uveitis due to T. gondii (p < 0.05). The test is useful for differentiating active posterior uveitis due to toxoplasmosis from uveitis caused by other diseases.
Resumo:
The present study investigated the diagnostic value of polymerase chain reaction (PCR) performed in parallel to conventional methods at an American tegumentary leishmaniasis (ATL) referral centre for diagnosis. Accuracy parameters for PCR were calculated using 130 patients with confirmed ATL (ATL group), 15 patients established with other diseases and 23 patients with a lesion suggestive of ATL, but without parasitological confirmation (NDEF group). PCR showed 92.3% sensitivity, 93.3% specificity, a 99.2% positive predictive value and a 13.84 positive likelihood ratio. In the NDEF group, PCR confirmed ATL in 13 of the 23 patients, seven of whom responded to leishmaniasis treatment and six who presented spontaneous healing of the lesion. PCR should be included in the routine diagnostic procedures for ATL, especially for cases found to be negative by conventional methods.
Resumo:
To evaluate commercial Lionex TB together with four antigens of Mycobacterium tuberculosis (MPT-64, MT10.3, 16 kDa and 38 kDa) for IgG and IgA cerebrospinal fluid (CSF) detection in the diagnosis of tuberculosis meningitis (TBM) with CSF negative acid-fast bacilli staining, 19 cases of TBM, 64 cases of other infectious meningoencephalitis and 73 cases of other neurological disorders were tested by enzyme linked immunosorbent assay. IgA-MPT-64 and IgG Lionex showed the highest sensitivities, specificities, positive predictive value and negative predictive value (63.2%, 47.4%; 95%, 93.7%; 40%, 98% and 28.4%, 97.1%, respectively). However, while grey zone was 12.7% and 6%, respectively, lowering sensitivity but maintains high specificity (> 95%). High protein concentration in CSF was associated with antibody positivity CSF/HIV+ which did not influence the sensitivity of both tests. To our knowledge, this is the first description of IgA-MPT-64 and IgG Lionex antibodies in CSF-TBM and, although there is good specificity, adjustments are needed based on antigen composition to enhance sensitivity.
Resumo:
The susceptibility of 49 Mycobacterium tuberculosis clinical isolates to isoniazid (INH) and rifampisin (RIF) (28 multi-drug resistant-tuberculosis samples) was determined by a nitrate reductase assay (NRA) on blood agar. Agreement between the NRA and other testing methods was found to be 93.8% for both INH and RIF. The sensitivity, specificity, positive predictive value and negative predictive value for INH were 92.8%, 94.2%, 86.6% and 97%, respectively. The sensitivity, specificity, positive predictive value and negative predictive value for RIF were 90.4%, 96.4%, 95% and 93.1%. In conclusion, we show here that blood agar can be used effectively for the NRA test.
Resumo:
The objective of the current study was to compare two rapid methods, the BBL Mycobacteria Growth Indicator Tube (MGIT TM) and Biotec FASTPlaque TB TM (FPTB) assays, with the conventional Löwenstein-Jensen (LJ) media assay to diagnose mycobacterial infections from paucibacillary clinical specimens. For evaluation of the clinical utility of the BBL MGIT TM and FPTB assays, respiratory tract specimens (n = 208), with scanty bacilli or clinically evident, smear negative cases and non-respiratory tract specimens (n = 119) were analyzed and the performance of each assay was compared with LJ media. MGIT and FPTB demonstrated a greater sensitivity (95.92% and 87.68%), specificity (94.59% and 98.78%), positive predictive value (94.91% and 99.16%) and negative predictive value (96.56% and 90.92%), respectively, compared to LJ culture for both respiratory tract and non-respiratory tract specimens. However, the FPTB assay was unable to detect nontuberculous mycobacteria and few Mycobacterium tuberculosis complex cases from paucibacillary clinical specimens. It is likely that the analytical sensitivity of FPTB is moderately low and may not be useful for the direct detection of tuberculosis in paucibacillary specimens. The current study concluded that MGIT was a dependable, highly efficient system for recovery of M. tuberculosis complexes and nontuberculous mycobacteria from both respiratory and non-respiratory tract specimens in combination with LJ media.
Resumo:
Although several studies have evaluated the role of p16INK4a as a diagnostic marker of cervical intraepithelial neoplasia (CIN) and its association with disease progression, studies regarding the role of p16INK4a in human immunodeficiency virus (HIV)-infected patients remain scarce. The present study was designed to determine the potential utility of p16INK4a as a diagnostic marker for CIN and invasive cervical cancer in HIV-positive and negative cervical specimens. An immunohistochemical analysis of p16INK4a was performed in 326 cervical tissue microarray specimens. Performance indicators were calculated and compared using receiving operating characteristics curve (ROC)/area under the curve. In HIV-1-negative women, the percentage of cells that was positive for p16INK4a expression was significantly correlated with the severity of CIN (p < 0.0001). A ROC curve with a cut-off value of 55.28% resulted in a sensitivity of 89%, a specificity of 81%, a positive predictive value of 91% and a negative predictive value of 78%. HIV-seropositive women exhibited decreased expression of p16INK4a in CIN2-3 specimens compared with HIV-negative specimens (p = 0.031). The ROC data underscore the potential utility of p16INK4a under defined conditions as a diagnostic marker for CIN 2-3 staging and invasive cervical cancer. HIV-1 infection, however, is associated with relatively reduced p16INK4a expression in CIN 2-3.
Resumo:
The microplate nitrate reductase assay (MNRA) and the rezasurin microtitre assay (REMA) were used for the susceptibility testing of 73 clinical isolates and the results were compared with those that were obtained using the Bactec 460 TB and Bactec MGIT 960 systems. The REMA and the MNRA were performed in 96-well plates. For the REMA, the concentrations of isoniazid (INH) and rifampicin (RIF) ranged from 1.0-0.01 µg/mL and 2.0-0.03 µg/mL, respectively. For the MNRA, the INH concentration was between 1.0-0.03 µg/mL and the RIF concentration was between 2.0-0.06 µg/mL. For the MNRA, the sensitivity, specificity, positive predictive value, negative predictive value and INH/RIF agreement were 100/95.6, 97.6/100, 96.8/100, 100/98 and 98.6/98.6, respectively, and for the REMA, they were 100/91.3, 90.4/100, 88.5/100, 100/96.1 and 94.5/97.2, respectively. Our data suggest that these two rapid, low-cost methods may be inexpensive, alternative assays for the rapid detection of multidrug resistant tuberculosis in low-income countries.
Resumo:
Rabies is a neurotropic disease that is often lethal. The early diagnosis of rabies infection is important and requires methods that allow for the isolation of the virus from animals and humans. The present study compared a modified shell vial (MSV) procedure using 24-well tissue culture plates with the mouse inoculation test (MIT), which is considered the gold standard for rabies virus isolation. Thirty brain samples (25 positive and 5 negative by the fluorescent antibody test) obtained from different animal species at the National Institute of Hygiene Rafael Rangel in Caracas, Venezuela, were studied by the MIT and MSV assays. Nine samples (36%) were positive at 24 h, 10 (40%) were positive at 48 h and six (24%) were positive at 72 h by the MSV assay. With the MIT assay, 76% were positive at six days post inoculation and 12% were positive at 12 and 18 days post inoculation. One sample that was negative according to the MSV assay was positive with MIT on the 12th day. The MSV procedure exhibited a sensitivity of 96.2%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value 80%. This procedure allowed for rapid rabies virus detection. MIT can be employed as an alternative method in laboratories without tissue culture facilities.
Resumo:
The aim of the present study was to identify specific markers that mirror liver fibrosis progression as an alternative to biopsy when biopsy is contraindicated, especially in children. After liver biopsies were performed, serum samples from 30 hepatitis C virus (HCV) paediatric patients (8-14 years) were analysed and compared with samples from 30 healthy subjects. All subjects were tested for the presence of serum anti-HCV antibodies. Direct biomarkers for liver fibrosis, including transforming growth factor-β1, tissue inhibitor of matrix metalloproteinase-1 (TIMP-1), hyaluronic acid (HA), procollagen type III amino-terminal peptide (PIIINP) and osteopontin (OPN), were measured. The indirect biomarkers aspartate and alanine aminotransferases, albumin and bilirubin were also tested. The results revealed a significant increase in the serum marker levels in HCV-infected children compared with the healthy group, whereas albumin levels exhibited a significant decrease. Significantly higher levels of PIIINP, TIMP-1, OPN and HA were detected in HCV-infected children with moderate to severe fibrosis compared with children with mild fibrosis (p < 0.05). The diagnostic accuracy of these direct biomarkers, represented by sensitivity, specificity and positive predictive value, emphasises the utility of PIIINP, TIMP-1, OPN and HA as indicators of liver fibrosis among HCV-infected children.
Resumo:
Early detection of drug resistance in Mycobacterium tuberculosis isolates allows for earlier and more effective treatment of patients. The aim of this study was to investigate the performance of the malachite green decolourisation assay (MGDA) in detecting isoniazid (INH) and rifampicin (RIF) resistance in M. tuberculosis clinical isolates. Fifty M. tuberculosis isolates, including 19 multidrug-resistant, eight INH-resistant and 23 INH and RIF-susceptible samples, were tested. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and agreement of the assay for INH were 92.5%, 91.3%, 92.5%, 91.3% and 92%, respectively. Similarly, the sensitivity, specificity, PPV, NPV and agreement of the assay for RIF were 94.7%, 100%, 100%, 96.8% and 98%, respectively. There was a major discrepancy in the tests of two isolates, as they were sensitive to INH by the MGDA test, but resistant by the reference method. There was a minor discrepancy in the tests of two additional isolates, as they were sensitive to INH by the reference method, but resistant by the MGDA test. The drug susceptibility test results were obtained within eight-nine days. In conclusion, the MGDA test is a reliable and accurate method for the rapid detection of INH and RIF resistance compared with the reference method and the MGDA test additionally requires less time to obtain results.
Resumo:
The aim of this study was to investigate the performance of a new and accurate method for the detection of isoniazid (INH) and rifampicin (RIF) resistance among Mycobacterium tuberculosis isolates using a crystal violet decolourisation assay (CVDA). Fifty-five M. tuberculosis isolates obtained from culture stocks stored at -80ºC were tested. After bacterial inoculation, the samples were incubated at 37ºC for seven days and 100 µL of CV (25 mg/L stock solution) was then added to the control and sample tubes. The tubes were incubated for an additional 24-48 h. CV (blue/purple) was decolourised in the presence of bacterial growth; thus, if CV lost its colour in a sample containing a drug, the tested isolate was reported as resistant. The sensitivity, specificity, positive predictive value, negative predictive value and agreement for INH were 92.5%, 96.4%, 96.1%, 93.1% and 94.5%, respectively, and 88.8%, 100%, 100%, 94.8% and 96.3%, respectively, for RIF. The results were obtained within eight-nine days. This study shows that CVDA is an effective method to detect M. tuberculosis resistance to INH and RIF in developing countries. This method is rapid, simple and inexpensive. Nonetheless, further studies are necessary before routine laboratory implementation.
Resumo:
Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity.