91 resultados para Performance persistence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare hearing performance relating to the peripheral and central auditory system between solvent-exposed and non-exposed workers. METHODS: Forty-eight workers exposed to a mixture of solvents and 48 non-exposed control subjects of matched age, gender and educational level were selected to participate in the study. The evaluation procedures included: pure-tone audiometry (500 - 8,000 Hz), to investigate the peripheral auditory system; the Random Gap Detection test, to assess the central auditory system; and the Amsterdam Inventory for Auditory Disability and Handicap, to investigate subjects' self-reported hearing performance in daily-life activities. A Student t test and analyses of covariance (ANCOVA) were computed to determine possible significant differences between solvent-exposed and non-exposed subjects for the hearing level, Random Gap Detection test and Amsterdam Inventory for Auditory Disability and Handicap. Pearson correlations among the three measures were also calculated. RESULTS: Solvent-exposed subjects exhibited significantly poorer hearing thresholds for the right ear than non-exposed subjects. Also, solvent-exposed subjects exhibited poorer results for the Random Gap Detection test and self-reported poorer listening performance than non-exposed subjects. Results of the Amsterdam Inventory for Auditory Disability and Handicap were significantly correlated with the binaural average of subject pure-tone thresholds and Random Gap Detection test performance. CONCLUSIONS: Solvent exposure is associated with poorer hearing performance in daily life activities that relate to the function of the peripheral and central auditory system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this article was to describe the attention functioning of twenty-two truck drivers and its relationship with amphetamine use. Those drivers who reported using amphetamines in the twelve months previous to the interview had the best performance in a test evaluating sustained attention functioning. Although amphetamine use may initially seem advantageous to the drivers, it may actually impair safe driving. The findings suggest the importance of monitoring the laws regarding amphetamine use in this country.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To assess the impact of implementing long-stay beds for patients of low complexity and high dependency in small hospitals on the performance of an emergency referral tertiary hospital. METHODS For this longitudinal study, we identified hospitals in three municipalities of a regional department of health covered by tertiary care that supplied 10 long-stay beds each. Patients were transferred to hospitals in those municipalities based on a specific protocol. The outcome of transferred patients was obtained by daily monitoring. Confounding factors were adjusted by Cox logistic and semiparametric regression. RESULTS Between September 1, 2013 and September 30, 2014, 97 patients were transferred, 72.1% male, with a mean age of 60.5 years (SD = 1.9), for which 108 transfers were performed. Of these patients, 41.7% died, 33.3% were discharged, 15.7% returned to tertiary care, and only 9.3% tertiary remained hospitalized until the end of the analysis period. We estimated the Charlson comorbidity index – 0 (n = 28 [25.9%]), 1 (n = 31 [56.5%]) and ≥ 2 (n = 19 [17.5%]) – the only variable that increased the chance of death or return to the tertiary hospital (Odds Ratio = 2.4; 95%CI 1.3;4.4). The length of stay in long-stay beds was 4,253 patient days, which would represent 607 patients at the tertiary hospital, considering the average hospital stay of seven days. The tertiary hospital increased the number of patients treated in 50.0% for Intensive Care, 66.0% for Neurology and 9.3% in total. Patients stayed in long-stay beds mainly in the first 30 (50.0%) and 60 (75.0%) days. CONCLUSIONS Implementing long-stay beds increased the number of patients treated in tertiary care, both in general and in system bottleneck areas such as Neurology and Intensive Care. The Charlson index of comorbidity is associated with the chance of patient death or return to tertiary care, even when adjusted for possible confounding factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyze if size, administrative level, legal status, type of unit and educational activity influence the hospital network performance in providing services to the Brazilian Unified Health System.METHODS This cross-sectional study evaluated data from the Hospital Information System and the Cadastro Nacional de Estabelecimentos de Saúde (National Registry of Health Facilities), 2012, in Sao Paulo, Southeastern Brazil. We calculated performance indicators, such as: the ratio of hospital employees per bed; mean amount paid for admission; bed occupancy rate; average length of stay; bed turnover index and hospital mortality rate. Data were expressed as mean and standard deviation. The groups were compared using analysis of variance (ANOVA) and Bonferroni correction.RESULTS The hospital occupancy rate in small hospitals was lower than in medium, big and special-sized hospitals. Higher hospital occupancy rate and bed turnover index were observed in hospitals that include education in their activities. The hospital mortality rate was lower in specialized hospitals compared to general ones, despite their higher proportion of highly complex admissions. We found no differences between hospitals in the direct and indirect administration for most of the indicators analyzed.CONCLUSIONS The study indicated the importance of the scale effect on efficiency, and larger hospitals had a higher performance. Hospitals that include education in their activities had a higher operating performance, albeit with associated importance of using human resources and highly complex structures. Specialized hospitals had a significantly lower rate of mortality than general hospitals, indicating the positive effect of the volume of procedures and technology used on clinical outcomes. The analysis related to the administrative level and legal status did not show any significant performance differences between the categories of public hospitals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new cross-sectional survey of household- associated mongrel dogs as well as follow-up of previously parasitemic individuals was carried out in 1984 toy means of xenodiagnosis and serologic techniques to get a deeper insight into the relationship of T. cruzi parasitemia and age among canine hosts in a rural area of Argentina. Persistence of detectable parasitemia was age-independent, or at most, loosely related to age, confirming the pattern observed in 1982. Similarly no significant age-decreasing effect was recorded among seropositive dogs in: a) the probability of detecting parasites in a 2-year follow-up; b) their intensity of infectiousness (=infective force) for T. infestans 3rd-4th instar nymphs, as measured by the percentage of infected bugs observed in each dog xenodiagnosis. Moreover, not only was the infective force of seropositive dogs for bugs approximately constant through lifetime, but it was significantly higher than the one recorded for children in the present survey, and for human people by other researchers. Therefore, and since T. infestans field populations show high feeding frequencies on dogs, the latter are expected to make the greatest contribution to the pool of infected vectors in the rural household of Argentina. This characteristic should be sufficient to involve canine reservoirs definitely as a risk factor for human people residing in the same house. The increased severity of parasitemia observed among dogs in this survey may be related to the acute undernutrition characteristic of canine populations of poor rural areas in our country, which is expected to affect the ability of the host to manage the infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic performance indexes of sensitivity, specificity, positive predictive value and efficiency were determined for dot-ELISA and IgG-ELISA tests in 340 leishmaniasis sera. Sensitivity of the dot-ELISA was significantly lower than IgG-ELISA's; the two tests had indexes of specificity and positive predictive value of the same magnitude. Seventy-eight sera gave a negative dot-ELISA test result and a positive IgG-ELISA test result. When sera were classified according to different criteria as how to interpret this diversity, the kappa statistic did not corroborate the classification indicating that the two tests display a substantial strength of agreement. The results presented indicate that performance indexes accrued in a survey where variables arc well known may be extrapolated to other population studies if the disease presents itself as highly prevalent (due to a selection bias or not) and may be expected to discriminate a disease status among test positives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of an antigen of L. major-like promastigotes for the serological diagnosis of mucocutaneous leishmaniasis in the IgG-immunofluorescent test was compared to that of an antigen of L. braziliensis braziliensis. Each antigen was used to test two hundred and twenty-four sera of etiologies such as mucocutaneous leishmaniasis, deep mycoses, toxoplasmosis, malaria, Chagas' disease, visceral leishmaniasis, anti-nuclear factor, schistosomaiasis, rheumatoid factor and normal controls. Agreement between responses to each antigen was high: 77.2% of leishmaniases sera agreed on a positive or a negative result to both antigens and 91.1 % of control sera. Cross reactivity was restricted to Chagas' disease sera, visceral leishmaniasis, anti-nuclear factor and paracoccidiodomycosis. The quantitative response of leishmaniasis and Chagas' disease sera to both antigens was evaluated by a linear regression; although the y-intercept and the slope were different for each antigen, neither was better than the other in the disclosure of anti-Leishmania antibodies. In the case of Chagas' disease sera the L. major-like antigen was better than L. b. braziliensis' to disclose cross-reacting antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study evaluated six Plasmodium falciparum antigen extracts to be used in the IgG and IgM enzyme-linked immunosorbent assays (ELISA), for malaria diagnosis and epidemiological studies. Results obtained with eighteen positive and nine negative control sera indicated that there were statistically significant differences among these antigen extracts (Multifactor ANOVA, p< 0.0001). Urea, sodium deoxycholate and Zwittergent antigen extracts performed better than did the three others, their features being very similar for the detection of IgG antibodies. Urea, alkaline and sodium deoxycholate antigen extracts proved to be better than the others for the detection of IgM antibodies. A straight line relationship was found between the optical densities (or their respective log 10) and the log 10 of antibody dilutions, with a very constant slope. Thus serum titers could be determined by direct titration and by two different equations, needing only one serum dilution. For IgM antibody detections, log 10 expression gave results that better correlated with direct titration (95% Bonferroni). For IgG antibody detections, the titer differences were not significant. The reproducibility of antibody titers and antigen batches was also evaluated, giving satisfactory results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Granulomatous inflammation is the morphological substrate of a variety of important infectious diseases such as tuberculosis, leprosy, schistosomiasis and others. Nevertheless, although many aspects of this special type of inflammation are known, fundamental questions concerning granuloma formation, persistence, fate and significance for host-parasite relationships still remain to be elucidated. In this brief review, the basic and more relevant literature related to experimental investigations on granuloma physiopathology is presented. Based on recent investigations performed in our laboratory showing that MDF (Macrophage Deactivating Fator) secreted by epithelioid cells and characterized as the calcium-binding protein protein MRP-14 deactivates activated macrophages, a hypothesis to explain the persistence of granulomatous inflammation is put forward

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anti-Toxocara antibody production and persistence were studied in experimental infections of BALB/c mice, according to three different schedules: Group I (GI) - 25 mice infected with 200 T. canis eggs in a single dose; Group II (GII) 25 mice infected with 150 T. canis eggs given in three occasions, 50 in the 1st, 50 in the 5th and 50 in the 8th days; Group III (GIII) - 25 mice also infected with 150 T. canis eggs, in three 50 eggs portions given in the 1st, 14th and 28th days. A 15 mice control group (GIV) was maintained without infection. In the 30th, 50th, 60th, 75th, 105th and 180th post-infection days three mice of the GI, GII and GIII groups and two mice of the control group had been sacrificed and exsanguinated for sera obtention. In the 360th day the remainder mice of the four groups were, in the same way, killed and processed. The obtained sera were searched for the presence of anti-Toxocara antibodies by an ELISA technique, using T. canis larvae excretion-secretion antigen. In the GI and GII, but not in the GIII, anti-Toxocara antibodies had been found, at least, up to the 180th post-infection day. The GIII only showed anti-Toxocara antibodies, at significant level, in the 30th post-infection day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The persistence of agglutinins detected by MAT has created some problems to the interpretation of the results. The aim of this study was to examine the data of serology from 70 patients with serologically confirmed diagnosis of leptospirosis by during 3-13 months after being affected with leptospires in order to elucidate the interpretation of the persistence of agglutinins detected by MAT. Sixty-one patients sera (87.14%) had titers equal or greater than 800. Of these, two individuals maintained titers of 800 thirteen months after the onset. This study showed that only one sample of sera with high titers is not reliable to determine the time at which infection occurred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the standardization and evaluation of an in-house specific IgG avidity ELISA for distinguishing recent primary from long-term human cytomegalovirus (HCMV) infection. The test was standardized with the commercial kit ETI-CYTOK G Plus (Sorin Biomedica, Italy) using 8 M urea in phosphate-buffered saline to dissociate low-avidity antibodies after the antigen-antibody interaction. The performance of the in-house assay was compared to that of the commercial automated VIDAS CMV IgG avidity test (bioMérieux, France). Forty-nine sera, 24 from patients with a recent primary HCMV infection and 25 from patients with a long-term HCMV infection and a sustained persistence of specific IgM antibodies, were tested. Similar results were obtained with the two avidity methods. All 24 sera from patients with recently acquired infection had avidity indices compatible with acute HCMV infection by the VIDAS method, whereas with the in-house method, one serum sample had an equivocal result. In the 25 sera from patients with long-term infection, identical results were obtained with the two methods, with only one serum sample having an incompatible value. These findings suggest that our in-house avidity test could be a potentially useful tool for the immunodiagnosis of HCMV infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the Giemsa-stained thick blood smear (GTS) remains the gold standard for the diagnosis of malaria, molecular methods are more sensitive and specific to detect parasites and can be used at reference centers to evaluate the performance of microscopy. The description of the Plasmodium falciparum, P. vivax, P. malariae and P. ovale ssrRNA gene sequences allowed the development of a polymerase chain reaction (PCR) that had been used to differentiate the four species. The objective of this study was to determine Plasmodium species through PCR in 190 positive smears from patients in order to verify the quality of diagnosis at SUCEN's Malaria Laboratory. Considering only the 131 positive results in both techniques, GTS detected 4.6% of mixed and 3.1% of P. malariae infections whereas PCR identified 19.1% and 13.8%, respectively.