80 resultados para Nancy Campbell
Resumo:
OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta). Their ages ranged from 10 to 28 (mean of 16.7) years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%); 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7), mosaics (n=5), and deletions (n=3). No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively). This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.
Resumo:
OBJETIVO: Avaliar freqüência, correlações clínicas e influência prognóstica do potencial tardio no eletrocardiograma de alta resolução, em portadores de insuficiência cardíaca de diferentes etiologias. MÉTODOS: Foi estudado o eletrocardiograma de alta resolução, durante 42 meses, em 288 portadores de insuficiência cardíaca de diferentes etiologias, 215 homens (74,65%) e 73 mulheres (25,35), de idades entre 16 e 70 anos (média 51,5, desvio-padrão 11,24). As etiologias da insuficiência cardíaca foram: cardiomiopatia hipertensiva, 78(27,1%); cardiomiopatia dilatada idiopática, 73(25,4%); cardiomiopatia isquêmica, 65(22,6%); cardiomiopatia da doença de Chagas, 42(14,6%); cardiomiopatia alcoólica, 9(3,1%); cardiomiopatia periparto, 6(2,1%); valvopatias em 2(4,2%) e miocardite viral, 3(1,04%). Foram avaliadas a duração do QRS Standard, duração do QRS filtrado, duração do sinal abaixo de 40µV e a raiz quadrada nos últimos 40ms quanto a idade, sexo, etiologia, achados do eletrocardiograma de repouso de 12 derivações, do ecocardiograma, do eletrocardiograma de longa duração e mortalidade. Para a análise estatística, foram utilizados os testes: exato de Fisher, t de Student, de Man-Whitney, análise de variância, Log-HanK e o método de Kaplan-Meyer. RESULTADOS: O potencial tardio foi diagnosticado em 90 (31,3%) pacientes e não houve correlação com as etiologias. Sua presença associou-se a: menor consumo máximo de oxigênio a cicloergoespirometria (p=0,001); taquicardia ventricular sustentada e não sustentada ao Holter (p=0,001), morte súbita e mortalidade (p<0,05). Houve uma maior sobrevida nos pacientes sem potencial tardio. CONCLUSÃO: A presença de potencial tardio não se associou às etiologias e mostrou-se um marcador de pior prognóstico.
Resumo:
OBJETIVO: Analisar os parâmetros do eletrocardiograma de alta resolução da onda P no domínio do tempo (ECGAR-P) e compará-los com: a duração da onda P no eletrocardiograma clássico (P no ECG), o diâmetro atrial esquerdo (AE) e a fração de ejeção do ventrículo esquerdo (FE) obtidos no ecocardiograma, para avaliar pacientes com fibrilação atrial paroxística (FAP). MÉTODOS: Foram estudados 181 pacientes: 117 com FAP comprovada e 64 sem FAP. Os parâmetros do ECGAR-P foram: a duração da onda P filtrada (DPF), as voltagens da raiz quadrada média dos últimos 40, 30 e 20 ms da onda P filtrada (RMS 40, RMS 30 e RMS 20), a voltagem da raiz quadrada média dos potenciais da onda P filtrada (RMS P), a integral dos potenciais da onda P filtrada (Integral P) e a duração dos potenciais tardios da onda P filtrada abaixo de 3 µV (PT<3). RESULTADOS: Os parâmetros que apresentaram diferenças estatisticamente significantes entre os grupos foram: DPF, RMS 40, 30 e 20, PT<3, P no ECG e AE. Os cálculos pela curva ROC mostraram, para cada parâmetro, o melhor valor de corte e os estimadores de desempenho: sensibilidade, especificidade, área sob a curva e p-value (p) ou nível descritivo. CONCLUSÃO: O ECGAR-P no domínio do tempo mostrou-se melhor que o eletrocardiograma clássico e o ecocardiograma para identificar pacientes com fibrilação atrial paroxística.
Resumo:
OBJETIVOS: Avaliar a ativação elétrica cardíaca usando Mapeamento Eletrocardiográfico de Superfície (MES), em pacientes com ICC e bloqueio de ramo esquerdo [BRE] submetidos a terapia de ressincronização cardíaca (CRT) com implante de marca-passo átrio-biventricular (MP-BIV). MÉTODOS: Foram analisados os tempos médios de ativação elétrica cardíaca no ventrículo direito (tempo médio de ativação do VD [mVD]), área ântero-septal (mAS), e ventrículo esquerdo (mVE), de 28 pacientes (idade média 61,2±9,5 anos, ICC classe III-IV NYHA, fração de ejeção <40%, BRE com QRS médio 181,2±19,4ms, SÂQRS= -8,5º±68,6º), mostrados nos mapas de linhas isócronas do MES, antes e após implante de marca-passo átrio-biventricular, e comparados a valores obtidos em um grupo controle composto de indivíduos normais [GNL], em três situações: (1) BRE nativo, (2) estimulação do VD; e (3) estimulação átrio-biventricular. RESULTADOS: situação (1): mVD e mAS foram semelhantes (41,0±11,8ms x 43,6±13,4ms), com mVE tardio (81,0±12,5ms, p<0,01) perdendo o sincronismo com o VD e a área ântero-septal; situação (2): mVD foi maior que no GNL (86,8±22,9ms, p<0,001), com maior diferença entre mAS e mVE (63,4±20,7ms x 102,7±20,3ms; p<0,001); situação (3): mVE e mVD foram semelhantes (72,0±32,0ms x 71,6±32,3ms), mVD foi maior que no GNL e BRE nativo (71,6±32,3ms x 35,1±10,9ms e 41,0±11,8ms; p<0,001), mAS se aproximou do GNL e BRE nativo (51,3±32,8ms x 50,1±11,4ms e 43,6±13,4ms). CONCLUSÃO: Pelo mapeamento eletrocardiográfico de superfície, tempos de ativação semelhantes no VD e VE e próximos daqueles da região ântero-septal indicam padrões de ativação ventricular sincronizada em portadores de ICC e BRE durante estimulação átrio-biventricular.
Resumo:
FUNDAMENTO: Apesar de o limiar anaeróbio (LAn) ser utilizado na avaliação funcional de diferentes populações, estudos comparando métodos para sua identificação em diabéticos tipo-2 tem sido pouco realizados. OBJETIVO: Comparar protocolos de identificação do LAn em indivíduos diabéticos tipo 2 e em não-diabéticos, e analisar respostas relacionadas ao equilíbrio ácido-básico em intensidades relativas ao LAn. MÉTODOS: Diabéticos tipo 2 (n=10; 54,5±9,5 anos; 30,1±5,0 kg/m²) e jovens não-diabéticos (n=10; 36,6±12,8 anos; 23,9±5,0 kg/m²) realizaram teste incremental (TI) em ciclo ergômetro. O aumento desproporcional no equivalente ventilatório de oxigênio (VE/VO2) e lactatemia ([lac]) identificaram intensidades (Watts-W) correspondentes aos limiares ventilatório (LV) e de lactato (LL), respectivamente. A intensidade correspondente à menor glicemia ([glic]) foi considerada limiar glicêmico individual (LGI). O LAn também foi determinado por ajuste polinomial das razões VE/Watts (LV VE/W) e [lac]/Watts (LL[lac]/W), as quais identificaram intensidades acima das quais um aumento desproporcional na VE e [lac] ocorreram. RESULTADOS: Não foram observadas diferenças entre LL, LV, LG, LL[lac]/W e LV VE/W em diabéticos (85,0±32,1; 88,0±31,7; 86,0±33,8; 82,0±20,9 e 90,2±22,2W) e não-diabéticos (139,0±39,0; 133,0±42,7; 140,8±36,4; 122,7±44,3 e 133,0±39,1W). Contudo os valores de LAn diferiram significativamente entre grupos (p<0.001). A técnica de Bland-Altman confirmou concordância entre os protocolos. Reduções significativas no pH e pCO2 em paralelo a um aumento na [lac], pO2 e VE foram observadas em intensidades supra limiares. CONCLUSÃO: Os protocolos apresentaram, para ambos os grupos estudados, concordância na identificação do LAn, que se mostrou como uma intensidade de exercício acima da qual ocorre perda de equilíbrio ácido-básico.
Resumo:
FUNDAMENTO: O gene da enzima conversora de angiotensina (gene ECA) tem sido amplamente estudado em relação a fenótipos de aptidão cardiorrespiratória, contudo a associação do genótipo da ECA com corridas de meia-distância tem sido pouco investigada. OBJETIVO: O presente estudo investigou a possível influência da enzima conversora de angiotensina (ECA) (I/D) sobre a aptidão cardiovascular e o desempenho em corridas de meia-distância por parte de brasileiros jovens do sexo masculino. A validade da previsão de VO2max em relação ao genótipo da ECA também foi analisada. MÉTODOS: Um grupo homogêneo de homens jovens moderadamente ativos foi avaliado em um teste de corrida (V1600 m; m.min-1) e em um teste adicional em esteira ergométrica para a determinação de VO2max. Posteriormente, o [(0,177*V1600m) + 8.101] VO2max real e previsto foi comparado com os genótipos da ECA. RESULTADOS: O VO2max e V1600m registrados para os genótipos DD, ID e II foram 45,6 (1,8); 51,9 (0,8) e 54,4 (1,0) mL.kg-1.min-1 e 211,2 (8,3); 249,1 (4,3) e 258,6 (5,4 ) m.min-1, respectivamente e foram significativamente mais baixos para os genótipos DD (p < 0,05). O VO2max real e previsto não diferiram entre si, apesar do genótipo da ECA, mas o nível de concordância entre os métodos de VO2max real e estimado foi menor para o genótipo DD. CONCLUSÃO: Concluiu-se que existe uma possível associação entre o genótipo da ECA, a aptidão cardiovascular e o desempenho em corridas de média distância de jovens do sexo masculino moderadamente ativos e que a precisão da previsão do VO2max também pode ser dependente do genótipo da ECA dos participantes.
Resumo:
Con el objeto de aumentar la sensibilidad del diagnóstico histopatológico de lesiones cutáneas y mucocutáneas causada por subespecies del complejo Leismania braziliensis y para lograr una mejor visualización de los parásitos en las lesiones, se evaluó el método de la inmunoperoxidas indirecta para localizar en forma rápida y específica los amastigotas en biopsia de tejido afectado. Los cortes de tejido se fijaron en formol y se incluyeron en parafina; después se evaluaron por inmunohistoquímica usando un antisuero policlonal producido en conejo, como reactivo primario, Se examinaron 265 biopsias de pacientes con lesiones sospechosas de leishmaniasis de la costa Pacífica y región suroriental colombiana. a 1983 (72.8%) pacientes se les estableció el diagnóstico por métodos clínicos y/o poarasitológicos. Los resultados obtenidos por la inmunoperoxidasa en el grupo de pacientes a los cuales se les confirmó la leishmaniasis se compararn con la histopatología convencional, el examen directo de frotis y el aislamiento del parásito por cultivo del aspirado de la lesión. La localización inmunoenzimática de las amastigotas fue más efectivas (61.3%) que la histopatología com hematoxilina y eosina (34.6%), y que el frotis (43,9%). En cambio, el cultivo de aspirado fue más sensible (89.8%). La eficiencia del método de inmunoperoxidasa fue mayor en las lesiones recientes (72.5%) positivos en los casos con menos de tres meses de evolución) que en las lesiones más antiguas (55.6, 37.5 y 21.1% para 3-5.9, 6-11 meses y mayores o iguales a 12 mese, respectivamente). La combinación de frotis e inmunoperoxidasa incrementó el porcentaje de caso diagnosticados a 72.0%, lo que indica la importancia de combinar métodos para obtener una mayor eficiencia de diagnóstico. La especificidad fue de 100% en controles sanos y 92.9% en pacientes con lesiones causadas por agentes etiológicos distintos a leishmania.
Resumo:
Con el fin de determinar las clases de anticuerpo producido contra el parásito y la cinética de los mismos en relación a la evolución de la infección, se estudiaron los sueros de 133 pacientes infectados con Leishmania del complejo braziliensis. Se utilizó la prueba de inmunofluorescencia indirecta y amastigotas de L. mexicana amazonensis como antígeno. En los sueros obtenidos al momento de consultar para el diagnóstico se encontró IgM en 54 de los sueros absorbidos con Straphylococcus aureus Cowan I y en 5 de los no absorbidos. La IgM sólo se encontro en los sueros de pacientes con tiempo devolución de las lesiones < o = de 2 meses. la IgG se detectó en todos los sueros no absorbidos. Los sueros tomados durante recurrencia y después de cicatrización sólo presentaron IgG. El uso combinado de la prueba de Montenegro y/o título de IgM específico, aumentó el porcentage de pacientes con un diagnóstico inmunológico positivo en aquéllos cuyas lesiones tenían un tiempo de evolución menor de 2 meses. En los sueros de los 10 individuos sanos no se detectó inmunoglobulina específica a Leishmania y ninguno presentó reacción positiva a la prueba de Montenegro. Entre los 16 pacientes con otra etiología, 3 con esporotricosis, mostraron en su suero IgG reactiva con Leishmania pero ninguno incluyendo 2 con menos de dos meses de evolución de las lesiones presentó IgM. concluimos que en pacientes infectados con L. braziliensis la presencia de IgM e IgG específica a Leishmania esta asociado con el tiempo de evolución de las lesiones y el estado primario recurrente de la infección; demás la detección de IgM anti-Leishmania combinada con la respuesta de Mn sería de potencial utilidad en el diagnóstico clínico de la leishmaniasis tegumentaria temprana.
Resumo:
The use of molecular tools to detect and type Leishmania species in humans, reservoirs or sandflies has been pursued using different approaches. The polymerase chain reaction provided sensitivity to case this task, since the use of hybridization procedures alone employing specifics probes is hampered due to the low detection limit. In this report, we describe the different molecular targets used in our laboratory, aiming at the detection and specific typing of these protozoa. Different kits based on hybridization assays and PCR amplification using kinetoplast and nuclear targets are described and the results obtained from their use are reported.