101 resultados para Mean diameter
Resumo:
OBJETIVE: With the increased use of intracoronary stents, in-stent restenosis has become a clinically significant drawback in invasive cardiology. We retrospectively assessed the short- and long-term outcomes after excimer laser coronary angioplasty of in-stent restenosis. METHODS: Twenty-five patients with 33 incidents of in-stent restenosis treated with excimer laser coronary angioplasty (ELCA) were analyzed. Sixty-six percent were males, mean age of 73±11 years, and 83% were functional class III-IV (NYHA). ELCA was performed using 23 concentric and 10 eccentric catheters with a diameter of 1.6-2.2 mm, followed by balloon angioplasty (PTCA) and ultrasound monitoring. The procedure was performed in the following vessels: left anterior descending artery, 10; left circumflex artery, 8; right coronary artery, 6; left main coronary artery, 2; and venous bypass graft, 7. RESULTS: The ELCA was successful in 71% of the cases, and PTCA was 100% successful. The diameter of the treated vessels was 3.44±0.5mm; the minimal luminal diameter (MLD) increased from 0.30mm pre-ECLA to 1.97mm post-ELCA, and to 2.94mm post-PTCA (p<0.001). The percent stenosis was reduced from 91.4±9.5% before ECLA to 42.3±14.9% after ELCA and to 14.6 ± 9.3% after PTCA (p<0.001). Seventeen (68%) patients were asymptomatic at 6 months and 15 (60%) at 1 year. New restenosis rates were 8/33 (24.2%) at 6 months and 9 /33 (27.3%) at 12 months. CONCLUSION: ELCA is safe and effective for the treatment of in-stent restenosis. In the present sample, a slight increase in new restenotic lesions between 6 and 12 months was found.
Resumo:
OBJECTIVE: To assess the effect of transient and sustained variations in cardiac load on the values of the end-systolic pressure-diameter relation (ESPDR) of the left ventricle. METHODS: We studied 13 dogs under general anesthesia and autonomic blockade. Variations of cardiac loads were done by elevation of blood pressure by mechanical constriction of the aorta. Two protocols were used in each animal: gradual peaking and decreasing pressure variation, the "transient arterial hypertension protocol" (TAH), and a quick and 10 min sustained elevation, the "sustained arterial hypertension protocol"(SAH). Then, we compared the ESDR in these two situations. RESULTS: Acute elevation of arterial pressure, being it "transitory" or "sustained", did not alter the heart frequency and increased similarly the preload and after load. However, they acted differently in end systolic pressure-diameter relation. It was greater in the SAH than TAH protocol, 21.0±7.3mmHg/mm vs. 9.2±1.2mmHg/mm (p<0.05). CONCLUSION: The left ventricular ESPDR values determined during sustained pressure elevations were higher than those found during transient pressure elevations. The time-dependent activation of myocardial contractility associated with the Frank-Starling mechanism is the major factor in inotropic stimulation during sustained elevations of blood pressure, determining an increase in the ESPDR values.
Resumo:
OBJECTIVE: We conducted a comparative analysis of the in-hospital outcomes of patients who underwent primary percutaneous transluminal angioplasty (PTCA) or stent implantation because of an acute myocardial infarction (AMI) related to an acute vein graft occlusion. METHODS: Since 1991 the Brazilian Society of Hemodynamic and Interventional Cardiology has maintained a large database (CENIC). From these, we selected all consecutive patients, who underwent primary PTCA or stenting in the first 24 hours of AMI, with the target vessel being an occluded vein graft. Immediate results and major coronary events occurring up until hospital discharge were analyzed. RESULTS: During this period, 5,932 patients underwent primary PTCA or stenting; 158 (3%) of the procedures were performed because of an acute vein graft occlusion. Stenting was performed in 74 (47%) patients. Patients treated with stents had a higher success rate and lower mean residual stenosis compared with those who underwent primary balloon PTCA. The incidence of reinfarction and death were similar for stenting and balloon PTCA. CONCLUSION: Primary percutaneous treatment of AMI related to acute vein graft occlusion is still an uncommon practice. Primary stenting improved luminal diameter and offered higher rates of success; however, this strategy did not reduce the in-hospital reinfarction and death rate, compared with that occurring with PTCA treatment.
Resumo:
OBJECTIVE - To report the results of percutaneous occlusion of persistent ductus arteriosus with the Amplatzer prosthesis in 2 Brazilian cardiological centers. METHODS - From May 1998 to July 2000, 33 patients with clinical and laboratory diagnosis of persistent ductus arteriosus underwent attempts at percutaneous implantation of the Amplatzer prosthesis. The median age was 36 months (from 6 months to 38 years), and the median weight was 14kg (from 6 to 92kg). Sixteen patients (48.5%) were under 2 years of age at the time of the procedure. All patients were followed up with periodical clinical and echocardiographic evaluations to assess the presence and degree of residual shunt and possible complications, such as pseudocoarctation of the aorta and left pulmonary artery stenosis. RESULTS - The minimum diameter of the arterial ducts ranged from 2.5 to 7.0mm (mean of 4.0±1.0, median of 3.9). The rate of success for implantation of the prosthesis was 100%. Femoral pulse was lost in 1 patient. The echocardiogram revealed total closure prior to hospital discharge in 30 patients, and in the follow-up visit 3 months later in the 3 remaining patients. The mean follow-up duration was 6.4±3.4 months. All patients were clinically well, asymptomatic, and did not need medication. No patient had narrowing of the left pulmonary artery or of the aorta. No early or late embolic events occurred, nor did infectious endarteritis. A new hospital admission was not required for any patient. CONCLUSION - The Amplatzer prosthesis for persistent ductus arteriosus is safe and highly effective for occlusion of ductus arteriosus of varied diameters, including large ones in small symptomatic infants.
Resumo:
OBJECTIVE - To describe clinical observations of marked improvement in ventricular dysfunction in a medical office environment under circumstances differing from those in study protocols and multicenter studies performed in hospital or with outpatient cohorts. METHODS - Eleven cardiac failure patients with marked ventricular dysfunction receiving treatment at a doctors office between 1994 and 1999 were studied. Their ages ranged from 20 and 66 years (mean 39.42±14.05 years); 7 patients were men, 4 were women. Cardiopathic etiologies were arterial hypertension in 5 patients, peripartum cardiomyopathy in 2, nondefined myocarditis in 2, and alcoholic cardiomyopathy in 4. Initial echocardiograms revealed left ventricular dilatation (average diastolic diameter, 69.45±8.15mm), reduced left ventricular ejection fraction (0.38±0.08) and left atrial dilatation (43.36±5.16mm). The therapeutic approach followed consisted of patient orientation, elimination of etiological or causal factors of cardiac failure, and prescription of digitalis, diuretics, and angiotensinconverting enzyme inhibitors. RESULTS - Following treatment, left ventricular ejection fraction changed to 0.63±0.09; left ventricular diameters changed to 57.18±8.13mm, and left atrium diameters changed to 37.27±8.05mm. Maximum improvement was noted after 16.9±8.63 (6 to 36) months. CONCLUSION - Patients with serious cardiac failure and ventricular dysfunction caused by hypertension, alcoholism, or myocarditis can experience marked improvement in ventricular dysfunction after undergoing appropriate therapy within the venue of the doctor's office.
Resumo:
OBJECTIVE: To evaluate the relationship between 24-hour ambulatory arterial blood pressure monitoring and the prognosis of patients with advanced congestive heart failure. METHODS: We studied 38 patients with NYHA functional class IV congestive heart failure, and analyzed left ventricular ejection fraction, diastolic diameter, and ambulatory blood pressure monitoring data. RESULTS: Twelve deaths occurred. Left ventricular ejection fraction (35.2±7.3%) and diastolic diameter (72.2±7.8mm) were not correlated with the survival. The mean 24-hour (SBP24), waking (SBPw), and sleeping (SBPs) systolic pressures of the living patients were higher than those of the deceased patients and were significant for predicting survival. Patients with mean SBP24, SBPv, and SBPs > or = 105mmHg had longer survival (p=0.002, p=0.01 and p=0.0007, respectively). Patients with diastolic blood pressure sleep decrements (dip) and patients with mean blood pressure dip <=6mmHg had longer survival (p=0.04 and p=0.01, respectively). In the multivariate analysis, SBPs was the only variable with an odds ratio of 7.61 (CI: 1.56; 3704) (p=0.01). Patients with mean SBP<105mmHg were 7.6 times more likely to die than those with SBP > or = 105 mmHg CONCLUSION: Ambulatory blood pressure monitoring appears to be a useful method for evaluating patients with congestive heart failure.
Resumo:
OBJECTIVE: Exercise training programs have been proposed as adjuncts to treatment of heart failure. The effects of a 3-month-exercise-training-program with 3 exercise sessions per week were assessed in patients with stable systolic chronic heart failure. METHODS: We studied 24 patients with final left ventricle diastolic diameter of 70±10mm and left ventricular ejection fraction of 37±4%. Mean age was 52±16 years. Twelve patients were assigned to an exercise training group (G1), and 12 patients were assigned to a control group (G2). Patients underwent treadmill testing, before and after exercise training, to assess distance walked, heart rate, systolic blood pressure, and double product. RESULTS: In G2 group, before and after 3 months, we observed, respectively distance walked, 623±553 and 561± 460m (ns); peak heart rate, 142±23 and 146± 33b/min (ns); systolic blood pressure, 154±36 and 164±26 mmHg (ns); and double product, 22211± 6454 and 24293±7373 (ns). In G1 group, before and after exercise, we observed: distance walked, 615±394 and 970± 537m (p<0.003) peak heart rate, 143±24 and 143±29b/min (ns); systolic blood pressure, 136±33 and 133±24 mmHg (ns); and double product, 19907± 7323 and 19115±5776, respectively. Comparing the groups, a significant difference existed regarding the variation in the double product, and in distance walked. CONCLUSION: Exercise training programs in patients with heart failure can bring about an improvement in physical capacity.
Resumo:
OBJECTIVE: To evaluate whether left ventricular end-systolic (ESD) diameters £ 51mm in patients (pt) with severe chronic mitral regurgitation (MR) are predictors of a poor prognosis after mitral valve surgery (MVS). METHODS: Eleven pt (aged 36±13 years) were studied in the preoperative period (pre), median of 36 days; in the early postoperative period (post1), median of 9 days; and in the late postoperative period (post2), mean of 38.5±37.6 months. Clinical and echocardiographic data were gathered from each pt with MR and systolic diameter ³51mm (mean = 57±4mm) to evaluate the result of MVS. Ten patients were in NYHA Class III/IV. RESULTS: All but 2 pt improved in functional class. Two pt died from heart failure and infectious endocarditis 14 and 11 months, respectively, after valve replacement. According to ejection fraction (EF) in post2, we identified 2 groups: group 1 (n=6), whose EF decreased in post1, but increased in post2 (p=0.01) and group 2 (n=5), whose EF decreased progressively from post1 to post2 (p=0.10). All pt with symptoms lasting £ 48 months had improvement in EF in post2 (p=0.01). CONCLUSION: ESD ³51mm are not always associated with a poor prognosis after MVS in patients with MR. Symptoms lasting up to 48 months are associated with improvement in left ventricular function.
Resumo:
OBJECTIVE:To verify the influence of moderate- or high-pressure balloon inflation during primary coronary stent implantation for acute myocardial infarction. METHODS: After successful coronary stent implantation, 82 patients were divided into 2 groups according to the last balloon inflation pressure: group 1 (³12 to <16 atm) and group 2 (³16 to 20 atm), each with 41 cases. All patients underwent late coronary angiography. RESULTS: In group 1, the mean stent deployment pressure was 13.58±0.92 atm, and in the group 2 it was 18.15±1.66 atm. Stents implanted with moderate pressures (³12 to <16 atm) had a significantly smaller postprocedural minimal lumen diameter, compared to with those with higher pressure, with lesser acute gain (2.7± 0.4 mm vs 2.9±04 mm; p=0.004), but the late lumen loss (0,9±0,8 mm vs 0,9±0,6 mm) and the restenosis (22% vs. 17.1%) and target-vessel revascularization rates (9.8% vs 7.3%) were similar between the groups. CONCLUSION: During AMI stenting, the use of high pressures (³16 atm) did not cause a measurable improvement in late outcome, either in the late loss, its index, and the net gain, or in clinical and angiographic restenosis rates.
Resumo:
OBJECTIVE: To study atheromas, Mycoplasma pneumoniae (M. pneumoniae), and Chlamydia pneumoniae (C. pneumoniae). METHODS: C. pneumoniae was studied with immunohistochemistry and M. pneumoniae with in situ hybridization (ISH), in segments of coronary arteries (SCA) as follows: group A - thrombosed ruptured plaques (TRP) of 23 patients who died due to acute myocardial infarction (AMI); group B - 23 nonruptured plaques (NRP) of group A patients; group C - NRP of 11 coronary patients who did not die due to AMI; and group D - 11 SCA from patients with dilated cardiomyopathy or Chagas' disease without atherosclerosis. RESULTS: The mean number of C. pneumoniae+ cells/400x in groups A, B, C, and D was, respectively, 3.3±3.6; 1.0±1.3; 1.2±2.4; and 0.4±0.3; and the percentage of M. pneumoniae area was, respectively, 3.9±3.5; 1.5± 1.6; 0.9±0.9; and 0.4±0.2. More M. pneumoniae and C. pneumoniae were found in of group A than in group B (P<0.01). Good correlation was seen between the area of the vessel and the M. pneumoniae area in the plaque (r = 0.46; P=0.001) and between C. pneumoniae+ cells and CD4+ T lymphocytes (r = 0.42; P<0.01). The number of C. pneumoniae+ cells correlated with CD20+ B cells (r=0.48; P<0.01). CONCLUSION: M. pneumoniae and C. pneumoniae are more frequently found in TRP correlate with the intensity of the inflammation and diameter of the vessel (positive remodeling).
Resumo:
Background: Changes in the properties of large arteries correlate with higher cardiovascular risk. Recent guidelines have included the assessment of those properties to detect subclinical disease. Establishing reference values for the assessment methods as well as determinants of the arterial parameters and their correlations in healthy individuals is important to stratify patients. Objective: To assess, in healthy adults, the distribution of the values of pulse wave velocity, diameter, intima-media thickness and relative distensibility of the carotid artery, in addition to assessing the demographic and clinical determinants of those parameters and their correlations. Methods: This study evaluated 210 individuals (54% women; mean age, 44 ± 13 years) with no evidence of cardiovascular disease. The carotid-femoral pulse wave velocity was measured with a Complior® device. The functional and structural properties of the carotid artery were assessed by using radiofrequency ultrasound. Results: The means of the following parameters were: pulse wave velocity, 8.7 ± 1.5 m/s; diameter, 6,707.9 ± 861.6 μm; intima-media thickness, 601 ± 131 μm; relative distensibility, 5.3 ± 2.1%. No significant difference related to sex or ethnicity was observed. On multiple linear logistic regression, the factors independently related to the vascular parameters were: pulse wave velocity, to age (p < 0.01) and triglycerides (p = 0.02); intima-media thickness, to age (p < 0.01); diameter, to creatinine (p = 0.03) and age (p = 0.02); relative distensibility, to age (p < 0.01) and systolic and diastolic blood pressures (p = 0.02 and p = 0.01, respectively). Pulse wave velocity showed a positive correlation with intima media thickness (p < 0.01) and with relative distensibility (p < 0.01), while diameter showed a positive correlation with distensibility (p = 0.03). Conclusion: In healthy individuals, age was the major factor related to aortic stiffness, while age and diastolic blood pressure related to the carotid functional measure. The carotid artery structure was directly related to aortic stiffness, which was inversely related to the carotid artery functional property.
Resumo:
Background:Heart failure and atrial fibrillation (AF) often coexist in a deleterious cycle.Objective:To evaluate the clinical and echocardiographic outcomes of patients with ventricular systolic dysfunction and AF treated with radiofrequency (RF) ablation.Methods:Patients with ventricular systolic dysfunction [ejection fraction (EF) <50%] and AF refractory to drug therapy underwent stepwise RF ablation in the same session with pulmonary vein isolation, ablation of AF nests and of residual atrial tachycardia, named "background tachycardia". Clinical (NYHA functional class) and echocardiographic (EF, left atrial diameter) data were compared (McNemar test and t test) before and after ablation.Results:31 patients (6 women, 25 men), aged 37 to 77 years (mean, 59.8±10.6), underwent RF ablation. The etiology was mainly idiopathic (19 p, 61%). During a mean follow-up of 20.3±17 months, 24 patients (77%) were in sinus rhythm, 11 (35%) being on amiodarone. Eight patients (26%) underwent more than one procedure (6 underwent 2 procedures, and 2 underwent 3 procedures). Significant NYHA functional class improvement was observed (pre-ablation: 2.23±0.56; postablation: 1.13±0.35; p<0.0001). The echocardiographic outcome also showed significant ventricular function improvement (EF pre: 44.68%±6.02%, post: 59%±13.2%, p=0.0005) and a significant left atrial diameter reduction (pre: 46.61±7.3 mm; post: 43.59±6.6 mm; p=0.026). No major complications occurred.Conclusion:Our findings suggest that AF ablation in patients with ventricular systolic dysfunction is a safe and highly effective procedure. Arrhythmia control has a great impact on ventricular function recovery and functional class improvement.
Resumo:
Fecundity is one of the most important parameters in studying the reproductive output of Pleocyemata decapods, especially because of its relationship to the efficiency of population replacement. Knowledge of fecundity provides basic elements for understanding the reproductive strategies, dynamics, and evolution of a given population. The present investigation provides informations on fecundity, egg size, egg loss, and the relationship between fecundity and selected environmental features, for the spider crab Mithraculus forceps (A. Milne Edwards, 1875). Ovigerous crabs were collected each month during 2000, by SCUBA diving, at Couves Island (23º25'25"S, 44º52'03"W) on the northeastern coast of the state of São Paulo, Brazil. A total of 40 ovigerous females with egg in early development (initial stage) and 28 final stage eggs were obtained and analyzed. Mean fecundity, from eggs of the initial stage, was 402.8 ± 240.1 eggs, ranging from 60 to 1,123 eggs. Sizes of females ranged from 9.4 to 14.0 mm carapace width. Mean egg size was 0.56 ± 0.06 mm diameter. A 20.33% rate of egg loss was estimated by comparing the fecundities of batches of eggs in early and late development (40 initial batches and 28 final stages batches). There were no significant relationships between the water temperature or salinity and variations in fecundity. As in most brachyuran species, M. forceps showed a strong conservative relationship between fecundity and body size.