41 resultados para Local Variation Method
Resumo:
Radiation balance is the fraction of incident solar radiation upon earth surface which is available to be used in several natural processes, such as biological metabolism, water loss by vegetated surfaces, variation of temperature in farming systems and organic decomposition. The present study aimed to assess and validate the performance of two estimation models for Rn in Ponta Grossa city, Paraná State, Brazil. To this end, during the period of 04/01/2008 to 04/30/2011, from radiometric data collected by an automatic weather station set at the Experimental Station, of the State University of Ponta Grossa. We performed a linear regression study by confrontation between measurements made through radiometric balance and Rn estimates obtained from Brunt classical method, and the proposed method. Both models showed excellent performance and were confirmed by the statistical parameters applied. However, the alternative method has the advantage of requiring only global solar radiation values, temperature, and relative humidity.
Resumo:
The electrocardiography (ECG) QT interval is influenced by fluctuations in heart rate (HR) what may lead to misinterpretation of its length. Considering that alterations in QT interval length reflect abnormalities of the ventricular repolarisation which predispose to occurrence of arrhythmias, this variable must be properly evaluated. The aim of this work is to determine which method of correcting the QT interval is the most appropriate for dogs regarding different ranges of normal HR (different breeds). Healthy adult dogs (n=130; German Shepherd, Boxer, Pit Bull Terrier, and Poodle) were submitted to ECG examination and QT intervals were determined in triplicates from the bipolar limb II lead and corrected for the effects of HR through the application of three published formulae involving quadratic, cubic or linear regression. The mean corrected QT values (QTc) obtained using the diverse formulae were significantly different (ρ<0.05), while those derived according to the equation QTcV = QT + 0.087(1- RR) were the most consistent (linear regression). QTcV values were strongly correlated (r=0.83) with the QT interval and showed a coefficient of variation of 8.37% and a 95% confidence interval of 0.22-0.23 s. Owing to its simplicity and reliability, the QTcV was considered the most appropriate to be used for the correction of QT interval in dogs.
Resumo:
The Mathematica system (version 4.0) is employed in the solution of nonlinear difusion and convection-difusion problems, formulated as transient one-dimensional partial diferential equations with potential dependent equation coefficients. The Generalized Integral Transform Technique (GITT) is first implemented for the hybrid numerical-analytical solution of such classes of problems, through the symbolic integral transformation and elimination of the space variable, followed by the utilization of the built-in Mathematica function NDSolve for handling the resulting transformed ODE system. This approach ofers an error-controlled final numerical solution, through the simultaneous control of local errors in this reliable ODE's solver and of the proposed eigenfunction expansion truncation order. For covalidation purposes, the same built-in function NDSolve is employed in the direct solution of these partial diferential equations, as made possible by the algorithms implemented in Mathematica (versions 3.0 and up), based on application of the method of lines. Various numerical experiments are performed and relative merits of each approach are critically pointed out.
Resumo:
An axisymmetric supersonic flow of rarefied gas past a finite cylinder was calculated applying the direct simulation Monte Carlo method. The drag force, the coefficients of pressure, of skin friction, and of heat transfer, the fields of density, of temperature, and of velocity were calculated as function of the Reynolds number for a fixed Mach number. The variation of the Reynolds number is related to the variation of the Knudsen number, which characterizes the gas rarefaction. The present results show that all quantities in the transition regime (Knudsen number is about the unity) are significantly different from those in the hydrodynamic regime, when the Knudsen number is small.
Resumo:
We examined large-scale spatial variation of structural parameters and floristic composition in open Clusia scrub, a vegetation type of the Brazilian "restingas" (sandy coastal plain vegetation). This vegetation is organized in islands separated by sandy stretches with sparse herbaceous vegetation. We located 12 sample areas on three consecutive beach ridges, lying parallel to the coastline and at different distances from the ocean, in close proximity to two lagoons (Cabiúnas and Comprida). Each sample area was divided into three strips. We used the line intercept method to sample all woody plants ³ 50 cm tall. We used nested ANOVA to verify structural variation between different sampling scales. TWINSPAN analysis was performed to examine the variation in floristic composition between areas. The overall diversity index was 3.07. Six species are repeatedly dominant throughout the entire sampling area. There was homogeneity in relation to diversity and species richness between beach ridges but not within beach ridges. Floristic composition and structural parameters did not vary in relation to distance from the sea but floristic composition did vary as a function of proximity to Cabiúnas or Comprida lagoon. Differences in plant cover between sample areas may be related to the paleoformation of this sandy coastal plain.
Resumo:
The objective of the present investigation was to compare the sensitivity of an electronic nociceptive mechanical paw test with classical mechanical tests to quantify the intensity variation of inflammatory nociception. The electronic pressure-meter test consists of inducing the hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared with the classical von Frey filaments test and with the rat paw constant pressure test, a modification of the Randall and Selitto test developed by our group. When comparing the three methods, the electronic pressure-meter and the rat paw constant pressure test, but not the von Frey filaments test, detected time vs treatment interactions in prostaglandin E2 (PGE2)-induced hypernociception. Both methods also detected the PGE2-induced hypernociception in dose- (50-400 ng/paw) and time- (1-4 h) dependent manners, and time vs treatment interactions induced by carrageenin (25-400 µg/paw). Furthermore, the electronic pressure-meter test was more sensitive at early times, whereas the constant pressure test was more sensitive at later times. Moreover, the electronic pressure-meter test detected the dose-dependent antinociceptive effect of local indomethacin (30-300 µg/paw) and dipyrone (80-320 µg/paw) on carrageenin- (200 µg/paw) and PGE2- (100 ng/paw) induced hypernociception, respectively, and also detected the ineffectiveness of indomethacin (300 µg) on the effect of PGE2. Our results show that the electronic pressure-meter provides a sensitive, objective and quantitative mechanical nociceptive test that could be useful to characterize new nociceptive inflammatory mediators and also to evaluate new peripheral analgesic substances.
Resumo:
A procedure is described for the rapid determination of the intra-erythrocyte concentration of 6-mercaptopurine (6-MP) and its metabolites, 6-thioguanine nucleotides (6-TGN) and 6-methylmercaptopurine (6-MMP). Erythrocytes (8 x 10(8) cells) in 350 µl Hanks solution containing 7.5 mg dithiothreitol were treated with 50 µl 70% perchloric acid. The precipitate was removed by centrifugation (13,000 g) and the supernatant hydrolyzed at 100°C for 45 min. After cooling, 100 µl was analyzed directly by HPLC using a Radialpack Resolve C18 column eluted with methanol-water (7.5:92.5, v/v) containing 100 mM triethylamine. 6-TG, 6-MP and the hydrolysis product of 6-MMP, 4-amino-5-(methylthio)carbonyl imidazole, were monitored at 342, 322 and 303 nm using a Shimadzu SPD-M10A diode array UV detector. The analytes eluted at 5.3, 6.0 and 10.2 min, respectively. The calibration curves were linear (r² > 0.998), and the analytical recoveries were 73.2% for 6-TG, 119.1% for 6-MP and 97.4% for 6-MMP. The intra- and inter-assay variations were highest for 6-MP (9.6 and 14.3%, respectively). The lowest detectable concentrations were 3, 3 and 25 pmol/8 x 10(8) erythrocytes for 6-TG, 6-MP and 6-MMP, respectively. The quantification limits (coefficients of variation <15%) were 8, 10 and 70 pmol/8 x 10(8) erythrocytes for 6-TG, 6-MP and 6-MMP, respectively. The method was applied to the analysis of 183 samples from 36 children under chemotherapy for acute lymphoblastic leukemia. The concentrations of the metabolites in the red cells of the patients ranged from 0 to 1934 pmol/8 x 10(8) erythrocytes for 6-TGN, and from 0 to 105.8 and 0 to 45.9 nmol/8 x 10(8) erythrocytes for 6-MP and 6-MMP, respectively. The procedure gave results that were in agreement with those obtained with other methods designed to detect cases of non-compliance with treatment, including patient interviews and medical evaluation, among others, demonstrating its applicability to monitoring the treatment of leukemic children.
Resumo:
Centrally stimulated sweat rate produced by graded exercise until exhaustion was compared to the local sweat rate induced by pilocarpine, often used as a sweating index for healthy individuals. Nine young male volunteers (22 ± 4 years) were studied in temperate environment in two situations: at rest and during progressive exercise with 25 W increases every 2 min until exhaustion, on a cycle ergometer. In both situations, sweating was induced on the right forearm with 5 ml 0.5% pilocarpine hydrochloride applied by iontophoresis (1.5 mA, 5 min), with left forearm used as control. Local sweat rate was measured for 15 min at rest. During exercise, whole-body sweat rate was calculated from the body weight variation. Local sweat rate was measured from the time when heart rate reached 150 bpm until exhaustion and was collected using absorbent filter paper. Pharmacologically induced local sweat rate at rest (0.4 ± 0.2 mg cm-2 min-1) and mean exercise-induced whole-body sweat rate (0.4 ± 0.1 mg cm-2 min-1) were the same (P > 0.05) but were about five times smaller than local exercise-induced sweat rate (control = 2.1 ± 1.4; pilocarpine = 2.7 ± 1.2 mg cm-2 min-1), indicating different sudorific mechanisms. Both exercise-induced whole-body sweat rate (P < 0.05) and local sweat rate (P < 0.05) on control forearm correlated positively with pilocarpine-induced local sweat rate at rest. Assuming that exercise-induced sweating was a result of integrated physiological mechanisms, we suggest that local and whole-body sweat rate measured during graded exercise could be a better sweating index than pilocarpine.
Resumo:
The aim of this study was to explore the clinical efficacy of a novel retrograde puncture approach to establish a preperitoneal space for laparoscopic direct inguinal hernia repair with inguinal ring suturing. Forty-two patients who underwent laparoscopic inguinal hernia repair with retrograde puncture for preperitoneal space establishment as well as inguinal ring suturing between August 2013 and March 2014 at our hospital were enrolled. Preperitoneal space was successfully established in all patients, with a mean establishment time of 6 min. Laparoscopic repairs were successful in all patients, with a mean surgical time of 26±15.1 min. Mean postoperative hospitalization duration was 3.0±0.7 days. Two patients suffered from postoperative local hematomas, which were relieved after puncturing and drainage. Four patients had short-term local pain. There were no cases of chronic pain. Patients were followed up for 6 months to 1 year, and no recurrence was observed. Our results demonstrate that preperitoneal space established by the retrograde puncture technique can be successfully used in adult laparoscopic hernioplasty to avoid intraoperative mesh fixation, and thus reduce medical costs.
Resumo:
The sorption behavior of dry products is generally affected by the drying method. The sorption isotherms are useful to determine and compare thermodynamic properties of passion fruit pulp powder processed by different drying methods. The objective of this study is to analyze the effects of different drying methods on the sorption properties of passion fruit pulp powder. Passion fruit pulp powder was dehydrated using different dryers: vacuum, spray dryer, vibro-fluidized, and freeze dryer. The moisture equilibrium data of Passion Fruit Pulp (PFP) powders with 55% of maltodextrin (MD) were determined at 20, 30, 40 and 50 ºC. The behavior of the curves was type III, according to Brunauer's classification, and the GAB model was fitted to the experimental equilibrium data. The equilibrium moisture contents of the samples were little affected by temperature variation. The spray dryer provides a dry product with higher adsorption capacity than that of the other methods. The vibro-fluidized bed drying showed higher adsorption capacity than that of vacuum and freeze drying. The vacuum and freeze drying presented the same adsorption capacity. The isosteric heats of sorption were found to decrease with increasing moisture content. Considering the effect of drying methods, the highest isosteric heat of sorption was observed for powders produced by spray drying, whereas powders obtained by vacuum and freeze drying showed the lowest isosteric heats of sorption.
Resumo:
Abstract An accurate, reliable and fast multianalyte/multiclass ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method was developed and validated for the simultaneous analysis of 23 pharmaceuticals, belonging to different classes amphenicols, sulfonamides, tetracyclines, in honey samples. The method developed consists of ultrasonic extraction followed by UPLC–ESI–MS/MS with electrospray ionization in both positive mode and negative mode. The influence of the extraction solvents and mobile phase composition on the sensitivity of the method, and the optimum conditions for sample weight and extraction temperature in terms of analyte recovery were extensively studied. The identification of antibiotics is fulfilled by simultaneous use of chromatographic separation using an Acquity BEH C18 (100 mm x 2.1 mm, 1.7 µm) analytical column with a gradient elution of mobile phases and tandem mass spectrometry with an electrospray ionization. Finally, the method developed was applied to the determination of target analytes in honey samples obtained from the local markets and several beekeepers in Muğla, Turkey. Ultrasonic-extraction of pharmaceuticals from honey samples is a well-established technique by UPLC–ESI–MS/MS, the uniqueness of this study lies in the simultaneous determination of a remarkable number of compounds belonging to 23 drug at the sub-nanogram per kilogram level.