82 resultados para Linear Capillary Instability
Resumo:
Este trabalho apresenta a parte operacional do processo final envolvido na implantação de um programa de controle de qualidade por meio de testes rotineiros mecânicos e de radiação. O programa de controle de qualidade, durante 35 meses, mostrou a estabilidade excelente deste acelerador.
Resumo:
Adsorption of Cu(II), Ni(II), Pb(II) and Zn(II) ions from aqueous solutions by N-(3,4-dihydroxybenzyl) chitosan have been carried out. The Langmuir (L), Freundlich (F), Langmuir - Freundlich (LF), Redlich-Peterson (RP) and Tóth (T) adsorption isotherms models have been applied to fit the experimental data. Nonlinear regression computational program "Enzefitte", which is a library of the more commonly used adsorption isotherm equations for obtaining tabular outuput suitable for plotting theoretical of fitted isotherms, has been used to estimate the adsorption parameters. These parameters were used to calculate the amount adsorbed q calc., a function of concentration (C).
Resumo:
This paper describes the development of a methodology for solid phase extraction (SPE) and pre-concentration of nitrosamines from aqueous samples using granular activated charcoal as stationary phase. micelar electrokinetic capillary Chromatography (MEKC) was used for the separation and identification of the nitrosamines in the extracts. Using a sample with 50 µg l-1 of each nitrosamines standards (dimethylnitrosamine, DMN; diethylnitrosamine, DEN; N-nitrosopyrrolidine, NPYR; N-nitrosopiperidine, NPIP; N-nitrosomorpholine, NMOR), the methodology showed a range of recuperation from 29 to 107% with a linear zone between 10 and 500 µg l-1. The developed methodology can be applicable to the determination of these analytes in different aqueous samples.
Resumo:
In this paper a methodology for the computation of Raman scattering cross-sections and depolarization ratios within the Placzek Polarizability Theory is described. The polarizability gradients are derived from the values of the dynamic polarizabilities computed at the excitation frequencies using ab initio Linear Response Theory. A sample application of the computational program, at the HF, MP2 and CCSD levels of theory, is presented for H2O and NH3. The results show that high correlated levels of theory are needed to achieve good agreement with experimental data.
Resumo:
This article describes a novel approach to the separation of fatty acids ranging from 8 to 20 carbons using capillary electrophoresis with contactless conductivity detection. Complete separation of nine linear chain fatty acids (from C8:0 to C20:0) was achieved in 15 min under normal polarity operation. Limits of detection ranged from 35 to 319 µmol L-1 for C20:0 to C8:0, respectively. The optimized running electrolyte composition was 5.0 mmol L-1 phosphate buffer at pH 7, 4.0 mmol L-1 dimethyl-b-cyclodextrin, 2.0 mmol L-1 trimethyl-b-cyclodextrin, acetonitrile 50% (v/v), and methanol 20% (v/v). The applicability of the separation system was demonstrated by the analysis of coconut vegetable oil.
Resumo:
The environmental impact of detergents and other consumer products is behind the continued interest in the chemistry of the surfactants used. Of these, linear alkylbenzene sulfonates (LASs) are most widely employed in detergent formulations. The precursors to LASs are linear alkylbenzenes (LABs). There is also interest in the chemistry of these hydrocarbons, because they are usually present in commercial LASs (due to incomplete sulfonation), or form as one of their degradation products. Additionally, they may be employed as molecular tracers of domestic waste in the aquatic environment. The following aspects are covered in the present review: The chemistry of surfactants, in particular LAS; environmental impact of the production of LAS; environmental and toxicological effects of LAS; mechanisms of removal of LAS in the environment, and methods for monitoring LAS and LAB, the latter in domestic wastes. Classical and novel analytical methods employed for the determination of LAS and LAB are discussed in detail, and a brief comment on detergents in Brazil is given.
Resumo:
The presence of illicit drugs such as cocaine and marijuana in US paper currency is very well demonstrated. However, there is no published study describing the presence of cocaine and/or other illicit drugs in Brazilian paper currency. In this study, Brazilian banknotes were collected from nine cities, extracted and analyzed by capillary gas chromatography/mass spectrometry, in order to investigate the presence of cocaine. Bills were extracted with deionized water followed by ethyl acetate. Results showed that 93% of the bills presented cocaine in a concentration range of 2.38-275.10 µg/bill.
Resumo:
Gas chromatography coupled with mass spectrometry (GC-MS) is widely used for the characterization of volatile compounds. However, due to the complexity of the soluble coffee matrix, a complete identification of the components should not be based on mass spectra interpretation only. The linear index of retention (LRI) is frequently used to give support to mass spectra. The aim of this work is to investigate the characterization of the volatile compounds in soluble coffee samples by GC-MS using LRI values found with a HP-INNOWAX column. The method used allows a significant increase of the reliability of identifying compounds.
Resumo:
A gas chromatographic method has been developed for the assay of fluvastatin sodium (FLU). FLU was silylated with N,O-bis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 90 ºC for 30 min and analysed in a DB-1 column by capillary gas chromatograph with a flame ionization detector. The method was validated. The assay was linear over the concentration range at 10.0 to 50.0 µg mL-1. The limit of detection and the limit of quantitation were 1.0 and 3.0 µg mL-1, respectively. The recoveries of FLU derivatives were in the range of 99.25-99.80%. In inter-day and intra-day analysis, the values of relative standard deviation (%) and the relative mean error (%) were found between 0.20-0.80% and -0.20-0.75%, respectively. The developed method was succesfully applied to analyze the FLU content in tablet formulation. The results were statistically compared with those obtained by the official method, and no significant difference was found between the two methods. Therefore, it can be recommended for the quality control assay of FLU in pharmaceutical industry.
Validação de método espectrofotométrico na região do UV para quantificação de famotidina em cápsulas
Resumo:
This work describes the validation of a method for quantification of famotidine in capsules by UV spectrophotometry using as solvents buffer solution at pH 2.5 and buffer solution at pH 4.5. The results show that the method is practical, selective, accurate, precise and linear from 10.0 to 25.0 µg/mL of famotidine in both solvents. However, a variance analysis showed a lower mean percentage of famotidine when buffer at pH 2.5 is used. This effect was attributed to the instability of famotidine in acidic media. Therefore, the use of pH 4.5 buffer was considered suitable for analysis of famotidine in capsules.
Resumo:
A comparative study of a convergent and the linear synthetic pathway with respect to their relative greenish allowed the quantification of the advantages of the former with respect to atomic productivity as well as robustness. The calculations show that convergent pathways provide a decrease of costs together with a decrease of E factor and an increase of atomic economy which means that greenish is accompanied by an economic advantage. The influence of other features of the convergent pathways synthesis on the improvement of the synthesis greenish is discussed qualitatively.
Resumo:
This technical note describes the construction of a low-cost optical detector. This device is composed by a high-sensitive linear light sensor (model ILX554) and a microcontroller. The performance of the detector was demonstrated by the detection of emission and Raman spectra of the several atomic systems and the results reproduce those found in the literature.
Resumo:
Density of dilute aqueous solutions of 1,2 pentanediol, 2,4 pentanediol, 1,4 pentanediol and 1,5 pentanediol at 283.15, 288.15, 293.15, 298.15, 303.15 and 308.15 K in the concentration range 0.0000 to 0.0060 in mole fraction were determined by using Wood-Brusie type capillary neck pycnometers. The solute partial molar volume as a function of solute concentration for each system was correlated with a linear equation for each temperature to estimate the slope limit and the partial molar volume at infinite dilution, and the predominant hydrophilic-hydrophobic effect was found in this region.
Resumo:
In the current study, an alternative method has been proposed for simultaneous analysis of palmitic, stearic, oleic, linoleic, and linolenic acids by capillary zone electrophoresis (CZE) using indirect detection. The background electrolyte (BGE) used for the analysis of these fatty acids (FAs) consisted of 15.0 mmol L−1 NaH2PO4/Na2HPO4 at pH 6.86, 4.0 mmol L−1 SDBS, 8.3 mmol L−1 Brij 35, 45% v/v acetonitrile (can), and 2.1% n-octanol. The FAs quantification of FAs was performed using a response factor approach, which provided a high analytical throughput for the real sample. The CZE method, which was applied successfully for the analysis of pequi pulp, has advantages such as short analysis time, absence of lipid fraction extraction and derivatization steps, and no significant difference in the 95% confidence intervals for FA quantification results, compared to the gas chromatography official method (AOCS Ce 1h-05).
Resumo:
The nonlinear analysis of a general mixed second order reaction was performed, aiming to explore some basic tools concerning the mathematics of nonlinear differential equations. Concepts of stability around fixed points based on linear stability analysis are introduced, together with phase plane and integral curves. The main focus is the chemical relationship between changes of limiting reagent and transcritical bifurcation, and the investigation underlying the conclusion.