55 resultados para Laser emissions
Resumo:
The spectroscopic behavior of thioxanthone and benzil (diphenylethanedione or dibenzoyl) in the ionic liquid [bmim.PF6] has been investigated employing the laser flash photolysis technique. Triplet-triplet absorption spectra for these carbonyl compounds in [bmim.PF6] are similar to those observed in organic solvents. The triplet lifetime for thioxanthone in desogygenated samples is very long (71 μs), whereas in oxygen-saturated solution is 500 ns, which indicates the low oxygen solubility in this solvent. For benzil, lifetimes of 10 μs in [bmim.PF6] and 3.8 μs in acetonitrile were obtained. The decay for triplet thioxanthone and benzil follows a clear first order kinetics in [bmim.PF6], from which one can conclude that triplet-triplet annihilation is not an important decay process in this solvent.
Resumo:
This study investigated the emission of N2O during the sequential aerated (60-min) and non-aerated (30-min) stages of an intermittent aeration cycle in an activated sludge wastewater treatment plant (WWTP). N2O emission occurred during both stages; however, emission was much higher during aeration. Air stripping is the major factor controlling transfer of N2O from the sewage to the atmosphere. The N2O emissions exclusively from the aeration tank represented 0.10% of the influent total nitrogen load and the per capita emission factor was almost 3 times higher than that suggested by the IPCC for inventories of N2O emission from WWTPs.
Resumo:
Neste trabalho descreve-se a tecnologia envolvida na fabricação de um detector piroelétrico para aplicações na determinação da energia de feixe de lasers pulsados ou CW (onda contínua) modulados, utilizando-se do polímero Polifluoreto de Vinilideno PVDF. Os dados experimentais revelam que o detector tem resposta linear com a energia aplicada para o intervalo compreendido entre 0,4 a 6,8 mili-Joule/pulse para pulsos com largura temporal de 8,3 milissegundos.
Resumo:
Foram realizados estudos para avaliar a microestrutura, a dureza e a resistência à corrosão do titânio comercialmente puro-Ti c.p. soldado por laser e utilizado na confecção de prótese sobre implantes. Verificou-se que na soldagem a laser a microestrutura apresentou três regiões distintas: o cordão de solda, a zona afetada pelo calor - ZAC e o metal base. O Ti c.p. possui microestrutura granular, a microestrutura do cordão de solda é mais refinada e de maior dureza do que o metal base. A ZAC obtida por este processo de soldagem foi relativamente pequena quando comparada com o processo de soldagem por brasagem. Os ensaios eletroquímicos mostraram que a região da solda apresentou menor resistência à corrosão em meio de NaCl 0,15 molL-1 à temperatura ambiente.
Resumo:
Investigou-se o comportamento de juntas soldadas de uma liga a base de ouro utilizada na confecção de próteses odontológicas sobre implantes antes e após ser submetida ao processo de soldagem a laser. Constatou-se que houve uma mudança estrutural na região da solda e esta apresentou uma microestrutura dendrítica refinada e o metal base uma microestrutura granular bifásica com maior dureza e presença de precipitados de Au. Os ensaios eletroquímicos, em meio aerado de NaCl 0,15 molL-1 à temperatura ambiente, que simula as condições do ambiente oral, demonstraram que a junta soldada apresentou melhor desempenho frente à corrosão quando comparada ao metal base; provavelmente devida a estrutura metalúrgica desta região.
Resumo:
As pontas de pulverização são os componentes mais importantes dos pulverizadores na aplicação de agrotóxicos. Dessa forma, este trabalho teve como objetivo avaliar o espectro de gotas de pontas de pulverização hidráulicas de jato plano (standard e antideriva) e de jato cônico vazio, disponíveis no mercado, submetidas a diferentes pressões da calda. Em ambiente controlado, avaliou-se o espectro de gotas, por meio de um analisador a laser de gotas em tempo real, nas pressões de 200; 300 e 400 kPa para as pontas de jato plano, e de 400; 500 e 600 kPa para as pontas de jato cônico. Os resultados permitiram concluir que: o espectro de gotas foi influenciado pela vazão nominal das pontas e pela pressão da calda; o potencial de deriva das pontas de jato plano standard e de jato cônico vazio foi alto; o uso de pontas de pulverização antideriva dotadas de pré-orifício aumentou o diâmetro das gotas, constituindo-se, portanto, em fator auxiliar para a redução da deriva nas pulverizações, e a avaliação do espectro de gotas empregando-se a técnica da difração do raio laser mostrou-se rápida e precisa.
Resumo:
The proper management of agricultural crop residues could produce benefits in a warmer, more drought-prone world. Field experiments were conducted in sugarcane production areas in the Southern Brazil to assess the influence of crop residues on the soil surface in short-term CO2 emissions. The study was carried out over a period of 50 days after establishing 6 plots with and without crop residues applied to the soil surface. The effects of sugarcane residues on CO2 emissions were immediate; the emissions from residue-covered plots with equivalent densities of 3 (D50) and 6 (D100) t ha-1 (dry mass) were less than those from non-covered plots (D0). Additionally, the covered fields had lower soil temperatures and higher soil moisture for most of the studied days, especially during the periods of drought. Total emissions were as high as 553.62 ± 47.20 g CO2 m-2, and as low as 384.69 ± 31.69 g CO2 m-2 in non-covered (D0) and covered plot with an equivalent density of 3 t ha-1 (D50), respectively. Our results indicate a significant reduction in CO2 emissions, indicating conservation of soil carbon over the short-term period following the application of sugarcane residues to the soil surface.
Resumo:
O presente trabalho objetivou avaliar o espectro de gotas de pontas de pulverização hidráulicas, submetidas a diferentes pressões e composições de calda, por meio de um analisador de partículas a laser. Em delineamento inteiramente casualizado, avaliaram-se duas pontas de jato plano duplo com indução de ar (AD-IA/D 11002 e AD-IA/D 11004) e duas pontas de jato cônico vazio (MAG - 2 e MAG - 4), em esquema fatorial 3 x 2: três pressões de pulverização (207, 276 e 345 kPa para as pontas de jato plano duplo e 414; 483 e 552 kPa para as pontas de jato cônico); e duas composições de calda (água e água mais o adjuvante fosfatidilcoline + ácido propiônico). A adição do adjuvante reduziu o diâmetro da mediana volumétrica das gotas pulverizadas pelas pontas AD-IA/D 11002 e 11004; porém, teve efeito inverso com a ponta MAG - 4 e não o alterou com a ponta MAG - 2. Em condições climáticas adversas, não se recomenda o uso de pontas de jato cônico vazio, mesmo com a adição do adjuvante testado, em virtude do alto risco potencial de deriva.
Resumo:
We conducted a study of the processes associated to NH3 emission in naturally ventilated dairy cattle facilities, having described factors that regulate NH3 emission, as well as methodologies for measuring these emissions at these facilities. Appropriate techniques to mitigate NH3 emission in facilities located in regions with warm climates were also identified. The most effective mitigation techniques with simple implementation include strategies associated to: (i) installation design and flooring, which lead to reduced emissions, (ii) excreta pre-excretion, namely the use of diets with optimized crude protein content and increased milk production at farm level; and (iii) excreta post-excretion, particularly by changing the conditions of environmental monitoring within the premises, practice introduction or additive application in the management of excreta deposited on floors.
Resumo:
O câncer cérvico-uterino é muito comum em vários países da América Latina. As estatísticas de mortalidade e as taxas de incidência demonstram a sua real importância. O cânver cérvico-uterino freqüentemente é uma doença progressiva iniciada com mudanças intra-epiteliais, que podem se transformar em um processo invasivo, sendo o nosso objetivo tratar precocemente estas lesões quando ainda é possível a cura de 100%. Em nosso estudo prospectivo foram selecionadas 21 pacientes com neoplasia cervical intra-epitelial reatreadas pela citplogia e diagnosticadas pela histopatologia após biópsia dirigida pela colposcopia. O método terapêutico empregado foi a vaporização a laser com o CO2. Tiveram como pré-requisito os seguintes critérios: informação segura pela colposcopia da zona de transformação e afastar a presença de câncer invasivo; a neoplasia epitelial cervical deve ocupar a ectocervix sem nenhuma extensão para o canal cervical e correlação positiva entre a citologia, colposcopia e histologia. O uso de laser CO2 com microscópio permitiu precisão na aplicação e com vantagens de ser um procedimento ambulatorial diminuindo estresse cirúrgico das pacientes. Foi realizado sem anestesia e com duração média de 15 minutos. A cicatrização completou-se em torno de três semanas e com cuidados operatórios mínimos. Somente dois casos tiveram sangramento vaginal discreto no quinto e décimo dia de pós-operatório, resolvido com tamponamento vaginal por 24 horas. A colposcopia, cirurgia e o seguimento foram feitos pelo autor, tendo uma paciente sido submetida a uma segunda vaporização no quinto mês de controle. Somente uma paciente teve recidiva no 26° mês de seguimento e complementará o tratamento. As vinte outras restantes estão em controle sem recidiva de doença. Em vista dos resultados obtivemos um percentual de cura de 95%, que coincide com a literatura. O uso de laser CO2 no tratamento das neoplasias cervicais intra-epiteliais (NIC) ou virais tem sido estimulado como uma alternativa digna de ser seguida pelas seguintes razões: cirurgia de não contato, tratamento rápido e indolor, diminuição das custas da internação; complicações mínimas e sem efeito subseqüente sobre a fertilidade e competência cervical, menor necrose térmica, e possibilidade de novo tratamento ambulatorial. Por estas razões e pelo alto percentual de cura podemos concluir que a cirurgia proposta foi vantajosa para o tratamento da neoplasia cervical intra-epitelial, quando comparada com outros métodos de tratamento.
Resumo:
The Nd:YAG laser is used as the palliative treatment of obstructive and/or hemorrhagic intestinal lesions with an effective but temporary symptomatic relief, with symptoms and signs recurrence after six to eight weeks. This report describes the treatment of a patient bearing a low rectal adenocarcinoma through diode laser ablation and the result after 17 months.
Resumo:
OBJETIVO: Avaliar se o tratamento das malformações vasculares venosas congênitas realizado com o emprego da tecnologia laser oferece clareamento ou desaparecimento das lesões com elevado grau de satisfação informado pelos pacientes e observado pelo médico. MÉTODOS: O estudo retrospectivo reuniu 26 pacientes, portadores de malformação vascular venosa, dos quais 73,07% eram do sexo feminino e que foram tratados com o aparelho PhotoDerm®. O tratamento das malformações vasculares necessitou uma média de 6,43 sessões, com intervalos de seis a oito semanas. Os pacientes incluídos neste estudo apresentavam pele tipo II (57,40%) e tipo III (42,30%), conforme classificação de Fitzpatric. A idade média variou de 14 a 61 anos, com média de 36,70 anos. Os dados foram obtidos através do preenchimento de protocolo informado pelo paciente. RESULTADOS: Foi informado elevado grau de satisfação (96,16%) e apenas um caso (3,84%) parcialmente satisfeito, considerando o clareamento ou desaparecimento das lesões. Houve desaparecimento das lesões avaliado pelo profissional médico em 80,76% dos casos e em 19,24% apenas clareamento. CONCLUSÃO: O tratamento das malformações vasculares venosas com o Photo-Derm® é seguro e eficiente tendo proporcionado elevado grau de satisfação dos pacientes assim como bons resultados em relação ao desaparecimento das lesões.
Resumo:
OBJECTIVE: to compare the effects of low intensity laser therapy on in vitro bacterial growth and in vivo in infected wounds, and to analyze the effectiveness of the AsGa Laser technology in in vivo wound infections. METHODS: in vitro: Staphylococcus aureus were incubated on blood agar plates, half of them being irradiated with 904 nm wavelength laser and dose of 3J/cm2 daily for seven days. In vivo: 32 male Wistar rats were divided into control group (uninfected) and Experimental Group (Infected). Half of the animals had their wounds irradiated. RESULTS: in vitro: there was no statistically significant variation between the experimental groups as for the source plates and the derived ones (p>0.05). In vivo: there was a significant increase in the deposition of type I and III collagen in the wounds of the infected and irradiated animals when assessed on the fourth day of the experiment (p=0.034). CONCLUSION: low-intensity Laser Therapy applied with a wavelength of 904nm and dose 3J/cm2 did not alter the in vitro growth of S. aureus in experimental groups; in vivo, however, it showed significant increase in the deposition of type I and III collagen in the wound of infected and irradiated animals on the fourth day of the experiment.
Resumo:
OBJECTIVE: To gather and clarify the actual effects of low-level laser therapy on wound healing and its most effective ways of application in human and veterinary medicine.METHODS: We searched original articles published in journals between the years 2000 and 2011, in Spanish, English, French and Portuguese languages, belonging to the following databases: Lilacs, Medline, PubMed and Bireme; Tey should contain the methodological description of the experimental design and parameters used.RESULTS: doses ranging from 3 to 6 J/cm2 appear to be more effective and doses 10 above J/cm2 are associated with deleterious effects. The wavelengths ranging from 632.8 to 1000 nm remain as those that provide more satisfactory results in the wound healing process.CONCLUSION: Low-level laser can be safely applied to accelerate the resolution of cutaneous wounds, although this fact is closely related to the election of parameters such as dose, time of exposure and wavelength.