411 resultados para Líquida


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple liquid chromatographic method for the simultaneous determination of creatinine, hippuric acid, mandelic acid, phenylglyoxylic acid and o, m and p-methylhippuric acids was developed and validated. Sample preparation was only dilution with water (1:10), followed by centrifugation. Analysis was performed in a reversed phase column (Lichrospher RP 8ec), 250 x 4.0 mm, with isocratic elution with phosphate buffer pH 2.3 and acetonitrile (90:10, v/v). The method presents adequate linearity, precision and accuracy and allows the simultaneous determination of the biomarkers of exposure to toluene, xylene and styrene together with creatinine, reducing cost and laboratory time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bupivacaine (S75-R25, NovaBupi®) is an amide type local anesthetic widely used. The present work consists of the development and validation of analytical methodology for evaluation of NovaBupi® content in the poly-lactide-co-glycolide nanospheres (PLGA-NS) by high performance liquid chromatography. The separation was made using the reversed-phase column LC-18, acetonitrile/phosphate buffer 85:15 v/v as mobile phase and detection at 220 nm. The results obtained show that the analytical methodology is accurate, reproducible, robust and linear over the concentration range 10-220.0 g/mL of NovaBupi®. The method was applied to determine the encapsulation efficiency and evaluate the release profile of NovaBupi®, showing good results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high performance liquid chromatography (HPLC) method has been developed for a rapid determination of nimesulide in dissolution studies. Nimesulide was analyzed using 5 µm Lichrospher® RP-18 column (125 x 4 mm i.d.) and mobile phase acetonitrile: phosphate buffer pH=6.0 (55:45) at a flow-rate of 1.0 mL min-1. Detection was carried out at 300 nm at 25 ºC. The method was applied to analysis of nimesulide in in vitro release studies and showed a rapid and efficient analytical alternative for evaluation of dissolution profile of nimesulide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultra Performance Liquid Chromatography (UPLC) retains the same principles as High Performance Liquid Chromatography (HPLC), but uses 1-2.1 mm i.d. columns with sub-2 µm particles. It is considered the newest advance in analytical separation science. The use of these small particles with mobile phases at high linear velocities increases resolution and detectability and decreases analysis time. Thus, the analyses are faster, the solvent volume is smaller, the efficiency is higher and the detectability is 2-3 times higher when compared with HPLC analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development and validation of simple and selective analytical method for determination of 3.4-methylenedioxymethamphetamine (MDMA) in Ecstasy tablets, using high performance liquid chromatography with fluorescence detection. Analysis was performed in a reversed phase column (LiChrospher 100 C18, 150 x 4.6 mm, 5 µm), isocratic elution with phosphate buffer 25 mmol/L pH 3.0 and acetonitrile (95:5, v/v). The method presents adequate linearity, selectivity, precision and accuracy. MDMA concentration in analyzed tablets showed a remarkable variability (from 8.5 to 59.5 mg/tablet) although the tablet weights were uniform, indicating poor manufacturing control thus imposing additional health risks to the users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Valproic acid (VA) is a drug used to control seizures in several epileptic conditions. In VA pharmacotherapy, therapeutic drug monitoring is recommended to obtain adequate seizure control and avoid toxicity. The aim of this study was to validate a method for the determination of valproic acid in serum, employing high performance liquid chromatography with diode array detection (HPLC-DAD), after derivatization with phenacyl bromide. The calibration curve (y=0.0133x-0.0025) presented good linearity with r²=0.9999. Accuracy (101-115%), intra-assay precision (4.53-8.15%) and inter-assay precision (3.15-6.77%) were acceptable. The quantification limit was 2.0 µg/mL. The method presented similar results to enzyme immunoassay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method using ultrasonication extraction for the determination of 17 polycyclic aromatic hydrocarbons (PAHs), selected by the USEPA and NIOSH as "consent decree" priority pollutants, in soil by High Performance Liquid Chromatography (HPLC) was studied. Separation and detection were completed in 20 min with a C18 columm, acetonitrile-water gradient elution and ultraviolet absorption and fluorescence detections. The detection limits, for a 10 µL of solution injection, were less than 9,917 ng/g in UV detection and less than 1,866 ng/g in fluorescence detection. Several organic solvents were tested for extraction of the 17 PAHs from soils. Acetone was the best solvent among the three solvents tested, and the order of the extraction efficiencies was: acetone>methanol>acetonitrile. Ultrasonication using acetone as solvent extraction was used to evaluate the biodegradation of those compounds in contaminated soil during a vermicomposting process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validation of analytical methods is an important step in quality control. The main objective of this study is to propose an HPLC experiment to verify the parameters of validation of chromatographic methods, based on green chemistry principles, which can be used in experimental courses of chemistry and related areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different phenolic compound, 5- caffeoylquinic acid (5-CQA), caffeic acid (AC) and rutin (Ru) contents of yerba-mate (Ilex paraguariensis) Brazilian samples of 06 different regions of São Mateus - Paraná, during natural and accelerated industrial storage, were evaluated. For quantification, a reverse phase HPLC isocratic method was developed and validated using methanol:water (35:65 v/v) acidified with 0.5% acetic acid as mobile phase and a photodiode array detector. The six sample global average contents were (34.90 and 36.10 mg g-1) for 5-CQA, (0.18 mg g-1 and 0.23 mg g-1) for AC and (7.12 and 7.18 mg g-1) for Ru, respectively, for the natural and accelerated storage systems. The results showed that the 5-CQA and Ru content are kept constant during the storage while AC content increase only during accelerated storage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method based on high-performance liquid chromatography with electrochemical detection has been developed and applied to the determination of Solvent blue 14 (SA-14) and Solvent red 24 (SV-24) in fuel samples. The dyes were better separated on C18 column, using a mobile phase composed of acetonitrile and ammonium acetate (90:10, v/v). Detection was carried out at an oxidation potential of +0.85V. The detector response was linear at concentration range of 7.50×10-8 - 1.50×10-6 mol L-1 (r = 0.997) for SA-14 and SV-24, respectively. The method was used to quantify these dyes in fuels samples with satisfactory accuracy and precision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method has been developed and validated for the determination of an association of ampicillins in a lyophilized powder for injection by HPLC. The advantage of chromatographic method other than the microbiological one is that, it is possible to monitor precisely, out-of-specification results in quality control processes and also during stability studies, in which an association of ampicillins is present. The proposed HPLC method was developed by using forced degraded samples, in order to reach a selective analysis of ampicillins when in the presence of their degradation products. It was possible to detect benzatine and through indirect calculation, to determine the ampicillin sodium in the drug sample. The method showed to be selective, accurate, precise, robust and linear (from 45.92 to 36.04 μg mL-1 of total ampicillin and from 14.53 to 43.28 μg mL-1 of benzatine). The accuracy determined from recovery test, gave results in the range of 99.41% of total ampicillin to 100.31% of benzatine. Hence, it can be concluded that the proposed HPLC method is applicable for ampicillins determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple ultra-performance liquid chromatographic method for the simultaneous determination of sildenafil citrate and tadalafil was developed and validated. Sample preparation was dissolution in methanol, followed by centrifugation and dilution (1:10) with methanol. Analysis was performed in an Acquity® UPLC system with Acquity® BEH C18 column (2.1 x 50 mm, with 1.7 μm particles). The elution was isocratic with phosphate buffer pH 2.3 and acetonitrile (65:35, v/v) at a flow rate of 0.7 mL/min. The method presented adequate specificity, linearity, precision and accuracy and allowed the determination of the drugs in seized forensic samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows results on the characterization, by liquid chromatography coupled to high resolution tandem mass spectrometry (LC-IT-TOF-MS) with electrospray ionization, of organic compounds present in raw and treated effluents from a combined sewage treatment systems (upflow anaerobic sludge blanket-trickling filter). The sewage samples were prepared by C18 solid phase extraction and the spectra obtained from the various extracts were submitted to principal component analysis to evaluate their pattern and identify the major deprotonated species. Some target compounds were submitted to semiquantitative analysis, using phenolphtalein as internal standard. The results showed the anaerobic step had little impact on the removal of anionic surfactants (LAS), fatty acids, and some contaminantes such as bisphenol A and bezafibrate, whereas the aerobic post-treatment was very efficient in removing these organics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-temperature liquid chromatography (HTLC) is a technique that presents a series of advantages in liquid phase separations, such as: reduced analysis time, reduced pressure drop, reduced asymmetry factors, modified retentions, controlled selectivities, better efficiencies and improved detectivities, as well as permitting green chromatography. The practical limitations that relate to instrumentation and to stationary phase instability are being resolved and this technique is now ready to be applied for routine determinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The organic acids (tartaric, malic, citric, lactic and succinic) are de main components responsible for the acidity in the wine. This method for simultaneous determination of organic acids and interfering peaks in wines can be achieved in 16 min. The sample preceded by a dilution and filtration step. The chromatographic separation required one reversed phase column, isocratic mobile phase (acetonitrila, formic acid in water) and detection wavelength was set at 212 nm. The validation confirmed good repeatability, recovery and application in red and white wines.