80 resultados para High-resolution continuum source flame atomic absorption spectrometry
Resumo:
The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h-1 can be carried out with the proposed flow-batch analyser.
Resumo:
Nickel, although essential to plants, may be toxic to plants and animals. It is mainly assimilated by food ingestion. However, information about the average levels of elements (including Ni) in edible vegetables from different regions is still scarce in Brazil. The objectives of this study were to: (a) evaluate and optimize a method for preparation of vegetable tissue samples for Ni determination; (b) optimize the analytical procedures for determination by Flame Atomic Absorption Spectrometry (FAAS) and by Electrothermal Atomic Absorption (ETAAS) in vegetable samples and (c) determine the Ni concentration in vegetables consumed in the cities of Lorena and Taubaté in the Vale do Paraíba, State of São Paulo, Brazil. By means of the analytical technique for determination by ETAAS or FAAS, the results were validated by the test of analyte addition and recovery. The most viable method tested for quantification of this element was HClO4-HNO3 wet digestion. All samples but carrot tissue collected in Lorena contained Ni levels above the permitted by the Brazilian Ministry of Health. The most disturbing results, requiring more detailed studies, were the Ni concentrations measured in carrot samples from Taubaté, where levels were five times higher than permitted by Brazilian regulations.
Resumo:
This study proposes a method of direct and simultaneous determination of the amount of Ca2+ and Mg2+ present in soil extracts using a Calcium Ion-Selective Electrode and by Complexometric Titration (ISE-CT). The results were compared to those obtained by conventional analytical techniques of Complexometric Titration (CT) and Flame Atomic Absorption Spectrometry (FAAS). There were no significant differences in the determination of Ca2+ and Mg2+ in comparison with CT and FAAS, at a 95 % confidence level. Additionally, results of this method were more precise and accurate than of the Interlaboratorial Control (IC).
Resumo:
'Cachaça' is the Brazilian name for the spirit obtained from sugarcane. According to Brazilian regulations, it may be sold raw or with addition of sugar and may contain up to 5 mg/L of copper. Copper in "cachaça" was determined by titration with EDTA, using a homemade copper membrane electrode for end-point detection. It was found a pooled standard deviation of 0,057 mg/L and there was no significant difference between the results obtained by the potentiometric method and by flame atomic absorption spectrometry with standard addition. Among the 21 'cachaça' samples from 16 different brands analyzed, three overpassed the legal copper limit. For its characteristics of accuracy, precision, and speed, the potentiometric method may be employed advantageously in routine analysis, specially when low cost is a major concern.
Resumo:
In order to demonstrate the feasibility of slurry sampling for environmental studies, different methodologies were developed for Cu and Zn in antarctic limpets and Ni in river sediment with FAAS detection. Studies focusing particle size, acid concentration, slurry stability, selectivity, among others were carried out in order to define the better conditions for slurry analysis. A study related to the depth profile for Ni in the Atibaia River sediment was made after optimization conditions for this element. For accuracy check, certified reference material was used as well as decomposition with microwave oven.
Resumo:
A method for determination of lead and cadmium in aqueous samples using solvent microextraction and dithizone as complexing agent with FAAS was developed. Solvent microextraction parameters were optimized. The effect of foreign ions on the extraction yields was studied. The extraction was carried out until the aqueous to organic phase ratio achieved a 250 fold preconcentration of metals. For preconcentration times of 4 min the 3sigma detection limits, relative standard deviations (n=7) and linear calibration ranges were 1.6 mug L-1, 5.8% and 10.0 -- 80.0 mug L-1 for lead and 11.1 ng L-1, 5.9% and 0.3 -- 3.0 mug L-1 for cadmium, respectively. The solvent microextraction procedure presented here was applied to the determination of lead and cadmium in natural waters.
Resumo:
This paper describes a review on internal standardization in atomic absorption spectrometry with emphasis to the systematic and random errors in atomic absorption spectrometry and applications of internal standardization in flame atomic absorption spectrometry and electrothermal atomic absorption spectrometry. The rules for selecting an element as internal standard, limitations of the method, and some comments about the application of internal standardization in atomic absorption spectrometry and the future of this compensation strategy are critically discussed.
Resumo:
In this study, the preparation of the xerogel anilinepropylsilica is reported. The ability of the xerogel for extracting Al(III), Cr(III) and Fe(III) from ethanol was investigated at 25 ºC. The xerogel adsorption capacities were obtained from the adsorption isotherms by using the batch method. Flame atomic absorption spectrometry (FAAS) was used to estimate the concentration of metal ions in solution. The adsorption affinity follows the series Cr(III) > Fe(III) > Al(III) and the maximum adsorption capacities of the metal ions were 0.61, 0.52 and 0.43 mmol g-1, respectively.
Resumo:
A solid phase extraction procedure using Amberlite XAD-1180/Pyrocatechol violet (PV) chelating resin for the determination of iron and lead ions in various environmental samples was established. The procedure is based on the sorption of lead(II) and iron(III) ions onto the resin at pH 9, followed by elution with 1 mol/L HNO3 and determination by flame atomic absorption spectrometry. The influence of alkaline, earth alkaline and some transition metals, as interferents, are discussed. The recoveries for the spiked analytes were greater than 95%. The detection limits for lead and iron by FAAS were 0.37 µg/L and 0.20 µg/L, respectively. Validation of the method described here was performed by using three certified reference materials (SRM 1515 Apple Leaves, SRM 2711 Montana Soil and NRCC-SLRS-4 Riverine Water). The procedure was successfully applied to natural waters and human hair.
Resumo:
Concentrations of Fe, Mn, Co, Cr, Zn and Cu were determinated using flame atomic absorption spectrometry in nine lichen species of the Sul-Mato-Grossense cerrado. The average metal ion concentrations varied in the following ranges: Fe, 248.41-1568.01; Mn, 98.50-397.33; Co, 10.08-24.81; Cr, 18.24-44.26; Zn, 14.62-34.79 and Cu, 3.23-7.57 mg kg-1. Statistical analysis (Pearson and Cluster) applied to the metal ion concentrations indicated that the accumulation of these ions can be due to several anthropogenic sources including agricultural activities, mineral exploration, biomass burning, soil mineral composition and leather tanning processes by chromium.
Resumo:
A method for determination of Cr(III) and Cr(VI) in cement and cement-related materials was studied. Molecular absorption spectrophotometry based on 1,5-diphenylcarbazide as chromogenic reagent was used for determination of Cr(VI) after alkaline extraction. The total chromium concentration was determined using flame atomic absorption spectrometry (FAAS) after complete sample decomposition by fusion. The quantification of Cr(III) was accomplished by subtracting the Cr(VI) concentration from the total chromium concentration. The concentration of Cr(III) in the samples ranged from 10.9 to 88.0 mg kg-1, whereas only in few samples the Cr(VI) concentration was higher than the value established by the European Community to this type of sample [2 mg kg-1 Cr(VI)].
Resumo:
Intralaboratorial and interlaboratorial variabilities can be obtained by conducting an specially designed interlaboratory program. Using the analysis of variance technique one can calculate the r (repeatability) and R (reproducibility) indexes that can help participant laboratories to monitor their routine quality control procedures. An example is described using data obtained from an interlaboratory program where twelve laboratories determined total iron content in silicon metal sample by using flame atomic absorption spectrometry.
Resumo:
This work proposes an analytical procedure for direct determination of calcium, magnesium, manganese and zinc in buffalo milk by flame atomic absorption spectrometry (FAAS). Samples were diluted with a solution containing 10% (v/v) of water-soluble tertiary amines (CFA-C) at pH 8. For comparison, buffalo milk samples were digested with HNO3 and H2O2. According to a paired t-test, the results obtained in the determination of Ca, Mg, Mn and Zn in digested samples and in 10% (v/v) CFA-C medium were in agreement at a 95% confidence level. The developed procedure is simple, rapid, decrease the possibility of contamination and can be applied for the routine determination of Ca, Mg, Mn and Zn in buffalo milk samples without any difficulty caused by matrix constituents, such as fat content, and particle size distribution in the milk emulsion.
Resumo:
An efficient flotation method based on the combination of flame atomic absorption spectrometry (FAAS) and separation and preconcentration step for determination of Cr3+, Cu 2+, Co2+, Ni2+, Zn2+, Cd 2+, Fe3+ and Pb2+ ions in various real samples by the possibility of applying bis(2-hydroxyacetophenone)-1,4-butanediimine (BHABDI) as a new collector was studied. The influence of pH, amount of BHABDI as collector, sample matrix, type and amount of eluting agent, type and amount of surfactant as floating agent, ionic strength and air flow rates i.e. variables affecting the efficiency of the extraction system was evaluated. It is ascertained that metal ions such as iron can be separated simultaneously from matrix in the presence of 0.012 mM ligand, 0.025% (w/v) of CTAB to a test sample of 750 mL at pH 6.5. These ions can be eluted quantitatively with 6 mL of 1.0 mol L-1 HNO3 in methanol which lead to the enrichment factor of 125. The detection limits for analyte ions were in the range of 1.3-2.4 ng mL-1. The method has been successfully applied for determination of trace amounts of ions in various real samples.
Resumo:
This work proposed a procedure to examine ashes produced in burning lubricating oils used in public transportation, in Teresina PI. Sulphanilic acid was added to the oil samples, which were burned at 550 °C for three hours and 650 °C for two hours. The ash solutions were analyzed by FAAS and there were significant differences in the metal contents of the waste oil produced from normal car service. The quantification limits in μg g-1 were 5.9 (Fe), 4.4 (Pb), 1.7 (Ni), 2.1 (Cu), and 1.2 (Zn). The results showed positive accuracy and precision with recoveries between 88 and 108%, and RSD lower than 10%.