119 resultados para Hemangioma capilar
Resumo:
This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.
Resumo:
CE-MS has been increasingly used for analysis of a vast array of compounds. This article reviews the different electrophoretic modes, interfaces and mass analyzers that are commonly used in the CE-MS coupling, as well as the technique advantages and performance characteristics. A large compilation of CE-MS applications is also presented. Therefore, this review is both a guide for beginners and a collection of key references for people who are familiar to the technique. Furthermore, this is the first CE-MS review published in a Brazilian journal and marks the installation of the first two commercial CE-MS units in Sao Paulo State.
Resumo:
Capillary electrochromatography (CEC) is a separation technique in which the mobile phase flow is based on the application of a voltage across a packed capillary, which generates an electroosmotic flow that transports the analytes along the capillary toward the detector. As it combines the separation mechanisms of high-performance liquid chromatography (HPLC) and of capillary electrophoresis (CE), CEC can be considered a hybrid of HPLC and CE. This review presents some fundamental aspects of CEC and is focused on the instrumental advances of the technique, such as column technology, operation modes and detection systems, presenting recent papers on these topics and some applications and perspectives about CEC.
Resumo:
Capillary electrophoresis has become a well-established and routine-based separation technique. It is based on the differences between charged analyte mobility in aqueous or organic electrolytes. Its major limitation is the sensitivity due to small sample injection volumes and the narrow diameter of the capillaries, especially when UV detection is used. There are a number of ways to increase the concentration sensitivity. This report shows some on-line preconcentration strategies to perform it in free solution capillary electrophoresis that are based on manipulation of the analyte electrophoretic velocity during the sample introduction (stacking, field amplification and transient isotachophoresis).
Resumo:
This work describes the development of a home-made capillary electrophoresis (CE) system based on the capacitively coupled contactless conductivity detection (C4D) for the separation of the metallic species Zn2+, Cr3+, Pb2+, Cd2+, Co2+, Cu2+, Ni2+ e Tl+. A background electrolyte composed of MES/Histidine 0,02 mol L-1 (pH 5.0) was optimized for the separation of the metallic species by using organic solvents and complexing agents as additives. The system allowed the determination of the metallic species using MES/Histidine 0,02 mol L-1 and methanol 5% (pH 5.0) as a background electrolyte, 15 kV separation voltage and hydrodynamic injection by gravity.
Resumo:
This work describes CE preconcentration strategies based on the effect of manipulation of the disperse/secondary velocity. Introduced by Terabe et al. in 1984, micellar electrokinetic chromatography is a powerful separation approach that increases the usage of electrokinetic phenomena for the separation of nonionic compounds. The main disadvantage of MEKC is the low concentration sensitivity associated with the limited optical path length for on-capillary photometric detection and the limited volume of sample solution that can be injected. This paper compiles on-line concentration strategies for neutral analytes by sample stacking and sweeping in micellar electrokinetic chromatography.
Resumo:
This review describes the advantages and disadvantages of using capillary liquid chromatography (CLC), which is considered the newest member in the analytical separation science arsenal. Although CLC has tremendous potential for being the next major innovation in separatory analysis, it has not yet obtained great popularity compared to conventional high performance (and ultra-high performance) liquid chromatography. Comparisons are made between these techniques and some of the reasons that CLC has not yet reached its potential will be advanced.
Resumo:
In this work, a rapid and simple method using capillary electrophoresis (CE) was developed for the determination of the benzoate, sorbate, methyl and propylparaben in foodstuffs. A running buffer consisting of 20 mmol L-1 (pH = 9.3) tetraborate enabled separation of the analytes in less than 5 min. The detector wavelength was set at 220 nm. The method was successfully applied to the analysis of sodas, sweeteners, sauces and juices. The range of preservatives found were from 478.5-466.6 mg kg-1 for methylparaben , 83.7-231.3 mg kg-1 for sorbate and 336.7-428.3 mg kg-1 for benzoate.
Resumo:
O objetivo deste trabalho foi caracterizar ácidos húmicos (HA) de diferentes origens por eletroforese capilar de zona (CZE) e avaliar a influência da concentração do tampão borato nesta caracterização. Os resultados mostraram que HA de diferentes origens podem ser rapidamente caracterizados por CZE. Por esta técnica, a caracterização de HA é devido a diferenças na razão carga/tamanho e das propriedades dos componentes individuais, conseqüência de suas diferentes origens.
Resumo:
Neste trabalho avaliou-se o potencial alelopático de extratos orgânicos obtidos a partir das folhas de Calopogonium mucunoides sobre a germinação de sementes de algumas plantas daninhas comumente encontradas em áreas de pastagens cultivadas da Amazônia brasileira, as quais causam grandes danos à produtividade: Cassia tora (mata-pasto), Mimosa pudica (malícia) e Cassia occidentalis (fedegoso). Compostos secundários foram identificados e quantificados nos extratos brutos utilizando eletroforese capilar. Após identificar e quantificar os compostos presentes nos extratos realizaram-se novos bioensaios com os padrões dos compostos identificados a fim de verificar se os mesmos poderiam atuar como inibidores na germinação das sementes das plantas daninhas em estudo. Calopogonium mucunoides apresentou potencial alelopático o qual variou com a espécie de planta daninha estudada. Os protocolos desenvolvidos utilizando eletroforese capilar se mostraram eficientes e bastante específicos, sendo possível a separação e identificação de 5 classes de compostos nos extratos brutos sem necessidade de "clean up" ou fracionamento dos mesmos, com análises rápidas (em menos de 20 minutos) e baixas quantidades de solventes utilizadas quando comparadas aos métodos tradicionais de análises. Vários dos compostos identificados apresentaram potencial de inibição de germinação nas sementes estudadas, sendo malícia a mais sensível, os bioensaios também indicaram certo efeito sinérgico ao utilizar a mistura de compostos.
Resumo:
Apesar de a esplenectomia ser eficaz na abordagem terapêutica de pacientes com hemangioma esplênico, esse procedimento é acompanhado de elevada morbidade e até mortalidade, principalmente devido à sepse, quando realizado em crianças e adolescentes com sistema imunitário ainda imaturo. Para prevenir os efeitos adversos da asplenia, propõe-se neste artigo a esplenectomia parcial, com a retirada apenas da região do hemangioma, mantendo o restante do baço e preservando suas importantes funções.
Resumo:
OBJETIVO: Apresentar os resultados do tratamento cirúrgico em pacientes portadores de hemangioma hepático. MÉTODO: Foram estudados 20 pacientes portadores de hemangioma hepático cavernoso, operados entre fevereiro de 1991 e fevereiro de 2005. A idade dos pacientes variou de 16 a 72 anos (média de 42 anos) com predomínio do sexo feminino (80%), sendo que 85% deles eram sintomáticos. Todos os pacientes foram submetidos à ultrassonografia abdominal (US) e à tomografia computadorizada contrastada (TC). Utilizou-se incisão abdominal subcostal bilateral associada à incisão mediana. RESULTADOS: Durante o período de seguimento clínico não se constataram recidiva de sintomas ou de hemangioma. A morbidade pós-operatória representada por infecção da ferida cirúrgica foi observada em um (5%) paciente, insuficiência hepática leve em 40% e moderada em 15% que apresentaram evolução clínica satisfatória com o tratamento clínico instituido; em um (5%) verificou-se a ocorrência de bilioma que necessitou drenagem por punção abdominal. A maioria dos pacientes retornou as atividades habituais até o 3º. mês de pós-operatório. Não ocorreram óbitos nesta série de pacientes. CONCLUSÃO: A ressecção cirúrgica do hemangioma hepático, gigante ou sintomático, é opção de tratamento segura e eficaz, sendo que a extensão da ressecção varia de acordo com a localização e tamanho.
Resumo:
Neste trabalho foi investigado o índice de HMF (5-hidroximetilfurfural) em méis comercializados em Porto Alegre - RS, utilizando Cromatografia Capilar Eletrocinética Micelar. O HMF, produto da condensação da frutose, é um indicador da qualidade e conservação do mel. Foram analisadas 11 marcas de méis comercializados na cidade de Porto Alegre. O composto estudado esteve presente em todas as amostras, em um intervalo de concentração de 0,191 a 6,206 mg.kg-1. Para quantificar o HMF presente nos méis, utilizou-se a técnica de adição de padrão. A taxa de recuperação foi de 98% e o limite de detecção foi de 0,025 mg.kg-1. O limite permitido de HMF em méis, segundo a legislação brasileira, é de 60 mg.kg-1.