210 resultados para HPLC-UV bioanalytical methodology


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The use of antioxidants either to prevent or retard food's lipids oxidation was approved after inquires that verified their security within a daily intake limit. In this study, the methodology was developed and validated for the analysis of synthetic antioxidants: propylgallate (PG), tert-butylhydroquinone (TBHQ), butylhydroxyanisole (BHA), octylgallate (OG) and butylhydroxytoluene (BHT) in vegetables oils, margarine and hydrogenated fats by high performance liquid chromatographic. The methodology revealed itself efficient, with recovery rates above 90% for all antioxidant substances, besides good linearity in concentration range of 40-240 mg kg-1 (r = 0,999), repeatability with CV < 3,7% and limit of quantification 16.55, 10.32, 1.40, 3.76 and 9.30 mg/kg for BHT, BHA, PG, OG and TBHQ, respectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Electrodegradation of atrazine in water was performed using homemade (PA and PB) and purchased (PC) boron-doped diamond anodes. The degradation was monitored off-line by analyzing total organic carbon and high performance liquid chromatography with diode array detector (HPLC-DAD) and at-line by UV spectroscopy. The spectra were recorded every 2 min. The rank deficiency problem was resolved by assembling an augmented column-wise matrix. HPLC was employed to separate the original and byproducts degradation components. Aiming the same goal, multivariate curve resolution - alternating least squares (MCR-ALS) was applied to resolve the UV spectroscopic data. Comparison between HPLC and MCR-ALS separations is presented. By using MCR-ALS the spectra of atrazine and two byproducts were successfully resolved and the resulted concentration profiles properly represented the system studied. The ALS explained variance (R2) for PA, PB and PC was equal to 99.99% for all of them and the lack of fit for PA, PB and PC were 0.39, 0.34 and 0.54 respectively. The correlation (R) between the recovered and pure spectra were calculate for each electrodegradation, validating the MCR-ALS results. The average R was equal to 0.997. The spectral and concentration profiles described with this new approach are in agreement with HPLC-DAD results. The proposed method is an alternative to classical analyses for monitoring of the degradation process, mainly due to the simplicity, fast results and economy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper was to determine the 10-HDA in pure royal jelly and products containing royal jelly, using HPLC methodology. 10-HDA is the natural indicator of the presence of royal jelly in products and also gives the authenticity of pure royal jelly. The chromatographic conditions used were: isocratic system, C18-H column, auto sampler, diode array UV-VIS detector (225 nm), mobile phase with methanol/water (45:55), pH= 2.5 and a-naphtol as internal standard. The results obtained using laboratory samples for pure royal jelly were 2.37%, varying from 0.15% for honey with 10% of royal jelly to 2.10% for honey with 90% of royal jelly respectivelly. For commercial products, the 10-HDA content varied from no detectable to 0.026%. The recovery test presented a minumum of 100.44% The detection limit was 45.92 ng/mL and the quantification limit was 76.53 ng/mL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Large differences in reduced glutathione (GSH) levels have been found in different investigations, also in healthy people. GSH oxidation in vitro has been associated with sample acidification in the presence of oxihemoglobin. In this work, the influence of different acids on GSH determination utilizing HPLC with UV detection was evaluated. The results showed that metaphosphoric acid and sulfosalicylic acid were inadequate for analysis, because metaphosphoric acid showed to be inefficient for deproteinization and with sulfosalicylic acid loss of GSH was observed. Trichloroacetic acid did not effect GSH quantification, since the deproteinized form was immediately derivatized with 5, 5´-dithio-bis (2-nitrobenzoic) acid. Methods with TCA deproteinization presented linear results from 0.5 to 3.0 mM. The correlation coefficient between aqueous curves and GSH spiked RBC exceeded 0.99. Precision calculations showed CV lower than 10% and bias within ± 10% for concentrations of 0.5; 1.5 and 3.0 mM GSH. The recovery was higher than 94%. Moreover, GSH blood concentrations were independent of hemoglobin concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to develop and validate an analytical methodology for simultaneous determination of mebendazole and thiabendazole, two benzimidazoles used as anthelmintics. The method was based on high performance liquid chromatography, using a C18 column, a mobile phase composed of KH2PO4 0.05 mol L-1 and methanol 40:60 (v/v) and UV detection at 312 nm. The results showed that the method presented linearity from 60.0 to 140.0 µg mL-1 for mebendazole and from 99.6 to 232.4 g µL-1 for thiabendazole and it was considered selective, accurate, precise and robust according to the specific resolution from ANVISA, the Brazilian regulatory agency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The analytical method developed to evaluate tamoxifen in dog plasma samples was precise, accurate, robust and linear in the range of 5-200 ng/mL. The limits of detection and quantification were 0.981 ng/mL and 2.97 ng/mL, respectively. Besides, the intra-day precision and accuracy variations were 8.78 and 10.16%, respectively. Tamoxifen concentrations were analyzed by combined reversed phase liquid chromatography and UV detection (lambda=280 nm). The study was conducted using an open randomized 2-period crossover balanced design with a 1-week washout period between the doses. This simple, rapid and selective method is suitable for pharmacokinetic, bioavailability and bioequivalence studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The microbiological bioassay, UV-spectrophotometry and HPLC methods for assaying gatifloxacin in tablets were compared. Validation parameters such as linearity, precision, accuracy, limit of detection and limit of quantitation were determined. Beer's law was obeyed in the ranges 4.0-14.0 μg/mL for HPLC and UV-spectrophotometric method, and 4.0-16.0 μg/mL for bioassay. All methods were reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate, precise and reproducible. The bioassay and HPLC are more specific than UV-spectrophotometric analysis. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the development and validation of an UV-Visible spectrophotometric method for quantitation of genistein and genistin in soy dry extracts, after reaction with aluminum chloride. The method showed to be linear (r²= 0.9999), precise (R.S.D. < 2%), accurate (recovery of 101.56%) and robust. Seven samples of soy dry extracts were analyzed by the spectrophotometric validated method and by RP-HPLC. Genistein concentrations determined by spectrophotometry (0.63% - 16.05%) were slightly higher than values obtained by HPLC analysis (0.40% - 12.79%); however, the results of both methods showed a strong correlation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple, robust, versatile, high analytical frequency method was proposed to check if a sample of wine is within the range of standards set by the manufacturer, using the UV-VIS spectroscopy, multivariate analysis and a flow-batch analyzer. Two hundred and fifty-two samples of wines were analyzed. The results from the application of Hierachical Cluster Analysis (HCA) to the matrix of the data involving all samples show the formation of fifteen types of wine. A Soft Independent Modelling of Class Analogy (SIMCA) model was constructed and used to classify the samples of the overall forecast. As a result, it is observed that the prediction was performed with a success rate of 99.2% for a confidence level of 95%. This shows that the proposed methodology can be used as an effective tool for classifying of samples of wines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid, economical, reproducible, and simple direct spectrophotometric method was developed and validated for the assay of nitazoxanide in pharmaceutical formulations. Nitazoxanide concentration was estimated in water at 345 nm and pH 4.5. The method was suitable and validated for specificity, linearity, precision, and accuracy. There was no interference of the excipients in the determination of the active pharmaceutical ingredient. The proposed method was successfully applied in the determination of nitazoxanide in coated tablets and in powders for oral suspension. This method was compared to a previously developed and validated method for liquid chromatography to the same drug. There was no significative difference between these methods for nitazoxanide quantitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An UV-Vis spectrophotometry analytical method for quantifying Efavirenz was developed and validated as an alternative to replace the HPLC current method. The report method presents sample concentration of 10 μg mL-1, dissolved in a solution ethanol:water (60:40, v/v), economic and technically adequate for the purpose adopted. The results and the statistical treated proved that the method being considered an precise and accurate analytical low cost alternative for laboratory routine. The adaptability of this method in product and other analytical methods development has been challenged by mathematical calculation of drug extinction coefficient in water and methanol and practical experiments, showing interesting results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The simultaneous determination of two or more active components in pharmaceutical preparations, without previous chemical separation, is a common analytical problem. Published works describe the determination of AZT and 3TC separately, as raw material or in different pharmaceutical preparations. In this work, a method using UV spectroscopy and multivariate calibration is described for the simultaneous measurement of 3TC and AZT in fixed dose combinations. The methodology was validated and applied to determine the AZT+3TC contents in tablets from five different manufacturers, as well as their dissolution profile. The results obtained employing the proposed methodology was similar to methods using first derivative technique and HPLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A validation study of an UV spectrophotometric method was conducted for quantitative analysis of benznidazol (BZN) in a lipid. The analytical determinations were performed at 315 nm at 25 ºC. The emulsion components did not interfere on drug analyses, demonstrating the specificity of the methodology. A good linearity (r = 0.99995) and precision (RSD < 5.0%) for intra and inter-day studies, including the reproducibility test were observed. The accuracy ranged of 102.1 + 2.8 e 103.8 + 1.7%. The statistical analysis demonstrates a linear, precise, accurate and robust method for BZN quantification from the lipid emulsion system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study describes the validation of UV spectrophotometric method for quantitative determination of gemifloxacin mesylate (GFM) in tablets using methanol as solvent. The method was specific, linear, precise, exact and robust at 272 and 343 nm. The results confirmed that the method in both wavelengths is valid and useful to the routine quality control of GFM in coated tablets. The validate method was compared to liquid chromatography (HPLC), microbiological assay and visible (VIS) spectrophotometry, which were previously developed and validated to the same drug. There was not significative difference between the methods for GFM quantitation.