83 resultados para Gold standard
Resumo:
OBJECTIVE: To determine the utility of B-type natriuretic peptide (BNP) in the diagnosis of congestive heart failure (CHF) in patients presenting with dyspnea to an emergency department (ED). METHODS: Seventy patients presenting with dyspnea to an ED from April to July 2001 were included in the study. Mean age was 72±16 years and 33 (47%) were male. BNP was measured in all patients at the moment of admission to the ED. Emergency-care physicians, blinded to BNP values, were required to assign a probable initial diagnosis. A cardiologist retrospectively reviewed the data (blinded to BNP measurements) and assigned a definite diagnosis, which was considered the gold standard for assessing the diagnostic performance of BNP. RESULTS: The mean BNP concentration was higher in patients with CHF (n=36) than in those with other diagnoses (990±550 vs 80±67 pg/mL, p<0.0001). Patients with systolic dysfunction had higher BNP levels than those with preserved systolic function (1,180±641 vs 753±437 pg/mL, p=0.03). At a blood concentration of 200 pg/mL, BNP showed a sensitivity of 100%, specificity of 97.1%, positive predictive value of 97.3%, and negative predictive value of 100%. The application of BNP could have potentially corrected all 16 cases in which the diagnosis was missed by the emergency department physician. CONCLUSION: BNP measurement is a useful tool in the diagnosis of CHF in patients presenting to the ED with dyspnea.
Resumo:
Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM). Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM) as gold-standard and measurements taken before morning micturition (BM) and in the afternoon (AM), for the best diagnosis of systemic arterial hypertension (SAH), and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women) were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM); and with post-morning-micturition and evening measurements (PM+EM). All patients underwent echocardiography (for left ventricular hypertrophy - LVH) and urinary albumin measurement (for microalbuminuria - MAU). Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM) and (PM+EM), and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM) versus (PM+EM) were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM) and (PM+EM) were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.
Resumo:
Background:Heart transplantation is considered the gold standard therapy for the advanced heart failure, but donor shortage, especially in pediatric patients, is the main limitation for this procedure, so most sick patients die while waiting for the procedure.Objective:To evaluate the use of short-term circulatory support as a bridge to transplantation in end-stage cardiomyopathy.Methods:Retrospective clinical study. Between January 2011 and December 2013, 40 patients with cardiomyopathy were admitted in our Pediatric Intensive Care Unit, with a mean age of 4.5 years. Twenty patients evolved during hospitalization with clinical deterioration and were classified as Intermacs 1 and 2. One patient died within 24 hours and 19 could be stabilized and were listed. They were divided into 2 groups: A, clinical support alone and B, implantation of short-term circulatory support as bridge to transplantation additionally to clinical therapy.Results:We used short-term mechanical circulatory support as a bridge to transplantation in 9. In group A (n=10), eight died waiting and 2 patients (20%) were transplanted, but none was discharged. In group B (n=9), 6 patients (66.7%) were transplanted and three were discharged.The mean support time was 21,8 days (6 to 984h). The mean transplant waiting list time was 33,8 days. Renal failure and sepsis were the main complication and causeof death in group A while neurologic complications were more prevalent en group B.Conclusion:Mechanical circulatory support increases survival on the pediatric heart transplantation waiting list in patients classified as Intermacs 1 and 2.
Resumo:
AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.
Resumo:
Immunofluorescence and immunoperoxidase test directed against early viral antigens, and DNA-DNA hybridization were compared with viral isolation for their abilities to detect Cytomegalovirus (CVM) in the urine of 89 HIV infected patients. From the 100 urine samples collected, 70 were found positive by at least one method. Considering viral isolation as the "gold standard" technique, immunofluorescence and immunoperoxidase had a sensitivity of 92.3% and88% respectively, with a specificity in both cases of 95%. DNA-DNA hybridization showed a sensitivity of 90% but with lower (60%) specificity. All of the three assays were effective in detecting CVM from urine and the technical advantage of each is discussed.
Resumo:
The aim of this study was to develop a polymerase chain reaction (PCR) for the detection of respiratory syncytial virus (RSV) genomes. The primers were designed from published sequences and selected from conserved regions of the genome encoding for the N protein of subgroups A and B of RSV. PCR was applied to 20 specimens from children admitted to the respiratory ward of "William Soler" Pediatric Hospital in Havana City with a clinical diagnosis of bronchiolitis. The PCR was compared with viral isolation and with an indirect immunofluorescence technique that employs monoclonal antibodies of subgroups A and B. Of 20 nasopharyngeal exudates, 10 were found positive by the three assayed methods. In only two cases, samples that yielded positive RNA-PCR were found negative by indirect immunofluorescence and cell culture. Considering viral isolation as the "gold standard" technique, RNA-PCR had 100% sensitivity and 80% specificity. RNA-PCR is a specific and sensitive technique for the detection of the RSV genome. Technical advantages are discussed
Resumo:
Indirect drug susceptibility tests of Mycobacterium tuberculosis was done to investigate the accuracy and feasibility of a broth microdilution method (BMM) for determining minimal inhibitory concentrations of conventional drugs against M. tuberculosis. Test drugs included isoniazid (H), rifampicin (R), ethambutol (E), streptomycin (S) and pyrazinamide (Z). Fifty isolates of M. tuberculosis from patients who had never received drug therapy, and H37Rv strain for control, were evaluated in the system. When comparing this method with the gold standard proportional method in Lowenstein-Jensen medium, sensitivity of 100% for all drugs and specifities of 91, 100, 96, 98 and 85% were observed respectively for H, R, E, S and Z. The BMM was read faster (14-20 days) than the proportional method (20-28 days). The microdilution method evaluated allows the testing of multiple drugs in multiple concentrations. It is easy to perform and does not require special equipment or expensive supplies. In contrast to radiometric method it does not use radioactive material.
Resumo:
In order to evaluate the direct-method test of sensitivity to drugs used in the principal tuberculosis treatment regimes, in the Organon Teknika MB/BacT system, we tested 50 sputum samples positive to microscopy taken from patients with pulmonary tuberculosis and with clinical indications for an antibiogram, admitted sequentially for examination during the routine of the reference laboratory. The material was treated v/v with 23% trisodium phosphate solution, incubated for 24 h at 35°C, and neutralized v/v with 20% monosodium phosphate solution. The material was then centrifuged and the sediment inoculated into flasks containing Rifampin - 2 µg/ml, Isoniazid - 0.2 µg/ml, Pyrazinamide - 100 µg/ml, Ethambutol - 2.5 µg/ml, Ethionamide - 1.25 µg/ml, and Streptomycin - 2 µg/ml. The tests were evaluated using the indirect method in the BACTEC 460 TB (Becton Dickinson) system as the gold standard. The results showed that the Rifampin test performed best, i.e., 100% sensitivity at 95% Confidence Interval (82.2-100) and 100% specificity at 95% Confidence Interval (84.5-100), followed by Isoniazid and Pyrazinamide. In this experiment, 92% of the materials showed a final reading in 30 days; this period represents the time for primary isolation as well as the results of the sensitivity profile, and is within Centers for Disease Control and Prevention recommendations regarding time for performance of the antibiogram. The inoculated flasks showed no contamination during the experiment. The MB/BacT is shown to be a reliable, rapid, fully automated nonradiometric system for the tuberculosis antibiogram.
Resumo:
A total of 106 women with vaginitis in Nicaragua were studied. The positive rate for the identification of Candida species was 41% (44 positive cultures out of 106 women with vaginitis). The sensitivity of microscopic examination of wet mount with the potassium hydroxide (KOH) was 61% and 70% with Gram's stain when using the culture of vaginal fluid as gold standard for diagnosis of candidiasis. Among the 44 positives cultures, isolated species of yeast from vaginal swabs were C. albicans (59%), C. tropicalis (23%), C. glabrata (14%) and C. krusei (4%). This study reports the first characterization of 26 C. albicans stocks from Nicaragua by the random amplified polymorphic DNA method. The genetic analysis in this small C. albicans population showed the existence of linkage disequilibrium, which is consistent with the hypothesis that C. albicans undergoes a clonal propagation.
Resumo:
In this study, the use of Mtp-40 and alpha antigen polymerase chain reaction (PCR) amplification fragments for the precise tuberculosis (TB) diagnosis was evaluated. One hundred and ninety two different samples were obtained from 113 patients with suspected TB. Mtp-40 and alpha antigen protein genes were amplified by the PCR technique and compared to both the "gold standard" (culture) test, as well as the clinical parameters (including a clinical record and X-ray film exam in 113 patients). Thirty-eight of the 113 patients had a presumptive clinical diagnosis of TB; 74% being detected by PCR technique, 58% by culture and 44% by direct microscopic visualization. Weconclude that it is possible to use PCR as a suitable technique for the detection of any mycobacteria by means of the alpha antigen product, or the specific infection of Mycobacterium tuberculosis by means of the mtp-40 gene. This might be a good supporting tool in difficult clinical TB diagnosis and pauci-bacillary cases.
Resumo:
In order to evaluate the Organon Teknika MB/BacT system used for testing indirect susceptibility to the alternative drugs ofloxacin (OFLO), amikacin (AMI), and rifabutin (RIF), and to the usual drugs of standard treatment regimes such as rifampin (RMP), isoniazid (INH), pyrazinamide (PZA), streptomycin (SM), ethambutol (EMB), and ethionamide (ETH), cultures of clinical specimens from 117 patients with pulmonary tuberculosis under multidrug-resistant investigation, admitted sequentially for examination from 2001 to 2002, were studied. Fifty of the Mycobacterium tuberculosis cultures were inoculated into the gold-standard BACTEC 460 TB (Becton Dickinson) for studying resistance to AMI, RIF, and OFLO, and the remaining 67 were inoculated into Lowenstein Jensen (LJ) medium (the gold standard currently used in Brazil) for studying resistance to RMP, INH, PZA, SM, EMB, and ETH. We observed 100% sensitivity for AMI (80.8-100), RIF (80.8-100), and OFLO (78.1-100); and 100% specificity for AMI (85.4-100), RIF (85.4-100), and OFLO (86.7-100) compared to the BACTEC system. Comparing the results obtained in LJ we observed 100% sensitivity for RMP (80-100), followed by INH - 95% (81.8-99.1), EMB - 94.7% (71.9-99.7), and 100% specificity for all drugs tested except for PZA - 98.3 (89.5-99.9) at 95% confidence interval. The results showed a high level of accuracy and demonstrated that the fully automated, non-radiometric MB/BacT system is indicated for routine use in susceptibility testing in public health laboratories.
Resumo:
Four methods (chromogenic, acidimetric, inhibition, and iodometric) for demonstration of the beta-lactamase production by 70 isolates of Neisseria gonorrhoeae, were evaluated in Cuba. There was 100% correlation between all beta-lactamase methods and the standardized penicillin dilution susceptibility test for penicillinase-non-producing N. gonorrhoeae. For penicillinase-producing N. gonorrhoeae strains, there was a perfect correlation between the chromogenic method and penicillin susceptibility testing, but one and two strains failed to give a positive result for beta-lactamase with the inhibition/acidimetric and the iodometric methods, respectively. There was a high concordance between the chromogenic method, considered as gold standard and the rest of penicillinase tests evaluated: Kappa Index (KI) = 0.98 for inhibition/acidimetric methods and KI = 0.97 for the iodometric method. The four methods evaluated were accurate, reproducible, easily readable, economical, and ease to use for screening primary isolates of N. gonorrhoeae in Cuba. We recommended the use of the inhibition method, when testing the penicillinase activity in gonococcal isolates in provincial and municipal reference laboratories.
Resumo:
Global left ventricular (LV) systolic dysfunction is the strongest predictor of morbidity and mortality in Chagas disease. Echocardiography is considered the gold standard for the detection of LV dysfunction, but not always available in endemic areas where chagasic cardiomyopathy is most common. Brain natriuretic peptide (BNP) is a neurohormone that has been recently described as a simple and inexpensive diagnostic and prognostic marker for patients with congestive heart failure. Chagasic patients (n = 63) and non-infected healthy individuals (n = 18) were recruited prospectively and underwent complete clinical examination, echocardiography and 24-h Holter monitoring. BNP was measured from thawed plasma samples using the Triage BNP test. We observed high levels of BNP in association with depression of LV ejection fraction, with increase of LV end-diastolic diameter and with LV premature complexes. An elevated concentration of BNP, defined as a concentration of 60 pg/ml or more, had a sensitivity of 91.7%, specificity of 82.8%, positive predictive value of 52.4%, and negative predictive value of 98% for detecting LV dysfunction (LV ejection fraction < 40%).BNP measurement using a simple, relatively inexpensive and rapid test has a promising role in identifying LV dysfunction associated with chagasic cardiomyopathy. Equally important, patients with Trypanosoma cruzi infection who have low levels of BNP level in plasma have a very low likelihood of severe cardiac involvement, and echocardiography is probably not necessary.
Resumo:
Coagulase-negative staphylococci (CoNS) are an important cause of nosocomial bacteremia, specially in patients with indwelling devices or those submitted to invasive medical procedures. The identification of species and the accurate and rapid detection of methicillin resistance are directly dependent on the quality of the identification and susceptibility tests used, either manual or automated. The objective of this study was to evaluate the accuracy of two automated systems MicroScan and Vitek - in the identification of CoNS species and determination of susceptibility to methicillin, considering as gold standard the biochemical tests and the characterization of the mecA gene by polymerase chain reaction, respectively. MicroScan presented better results in the identification of CoNS species (accuracy of 96.8 vs 78.8%, respectively); isolates from the following species had no precise identification: Staphylococcus haemolyticus, S. simulans, and S. capitis. Both systems were similar in the characterization of methicillin resistance. The higher discrepancies for gene mec detection were observed among species other than S. epidermidis (S. hominis, S. saprophyticus, S. sciuri, S. haemolyticus, S. warneri, S. cohnii), and those with borderline MICs.
Resumo:
A study was carried out to compare the performance of a commercial method (MGIT) and four inexpensive drug susceptibility methods: nitrate reductase assay (NRA), microscopic observation drug susceptibility (MODS) assay, MTT test, and broth microdilution method (BMM). A total of 64 clinical isolates of Mycobacterium tuberculosis were studied. The Lowenstein-Jensen proportion method (PM) was used as gold standard. MGIT, NRA, MODS, and MTT results were available on an average of less than 10 days, whereas BMM results could be reported in about 20 days. Most of the evaluated tests showed excellent performance for isoniazid and rifampicin, with sensitivity and specificity values > 90%. With most of the assays, sensitivity for ethambutol was low (62-87%) whereas for streptomycin, sensitivity values ranged from 84 to 100%; NRA-discrepancies were associated with cultures with a low proportion of EMB-resistant organisms while most discrepancies with quantitative tests (MMT and BMM) were seen with isolates whose minimal inhibitory concentrations fell close the cutoff. MGIT is reliable but still expensive. NRA is the most inexpensive and easiest method to perform without changing the organization of the routine PM laboratory performance. While MODS, MTT, and BMM, have the disadvantage from the point of view of biosafety, they offer the possibility of detecting partial resistant strains. This study shows a very good level of agreement of the four low-cost methods compared to the PM for rapid detection of isoniazid, rifampicin and streptomycin resistance (Kappa values > 0.8); more standardization is needed for ethambutol.