41 resultados para Filters
Resumo:
To optimize the use of pesticides, several countries have carried out periodic inspections in agricultural sprayers. In Brazil, knowing the conditions of this machinery canguide researches and investments in guidelines for its use and maintenance. The objective of this study was to verify the state of sprayer maintenance used in the North of the state of Paraná, in Brazil. Several sprayer items were evaluated, such as: presence, status and scale of the manometer, status of the hose, status of the anti-drip component, presence of leaks, status of the bar, status of the filters, state of the spraying nozzles and errors in the targeted flow rate. Machines were named as approved when there was no failure in any item evaluated. The factor that caused the biggest level of reprove among the machines was incorrect scale of manometers, which reproved 84.55% of the machines evaluated. Other outstanding factor was the incorrect flow rate in 75.5% of the tested machines. Only one unit was approved from the total of 110 evaluated sprayers.
Resumo:
ABSTRACTObjective:to analyze the implementation of a trauma registry in a university teaching hospital delivering care under the unified health system (SUS), and its ability to identify points for improvement in the quality of care provided.Methods:the data collection group comprised students from medicine and nursing courses who were holders of FAPESP scholarships (technical training 1) or otherwise, overseen by the coordinators of the project. The itreg (ECO Sistemas-RJ/SBAIT) software was used as the database tool. Several quality "filters" were proposed to select those cases for review in the quality control process.Results:data for 1344 trauma patients were input to the itreg database between March and November 2014. Around 87.0% of cases were blunt trauma patients, 59.6% had RTS>7.0 and 67% ISS<9. Full records were available for 292 cases, which were selected for review in the quality program. The auditing filters most frequently registered were laparotomy four hours after admission and drainage of acute subdural hematomas four hours after admission. Several points for improvement were flagged, such as control of overtriage of patients, the need to reduce the number of negative imaging exams, the development of protocols for achieving central venous access, and management of major TBI.Conclusion: the trauma registry provides a clear picture of the points to be improved in trauma patient care, however, there are specific peculiarities for implementing this tool in the Brazilian milieu.
Resumo:
We studied the flora of vegetation islands on rock outcrops on the Itatiaia Plateau (22°21'S and 44°40'W), at 2,400 m.a.s.l. A total of 114 vascular plant species, which correspond to ca. 20%-25% of the currently inventoried flora of the plateau, were sampled in 197 small vegetation islands (total area of 0.034 ha). Xerophytes and hydrophytes were often found side by side due to environmental heterogeneity at a small scale, explaining in part the high species diversity. Rock outcrops may support floras quite distinct from those in neighbouring habitats, due to the action of strong environmental filters, but in Itatiaia the geographic distribution patterns among rupicolous plants appear to mimic those described for the whole flora around it, with 15.1% of narrow endemic species and six strictly rupicolous plants. Underlining the "temperate" nature of the high elevation climate in Itatiaia, the sampled flora was dominated by species of the families Asteraceae and Poaceae, and the number of CAM (crassulacean acid metabolism) species was very low. A few endemic species of tropical origin - Pleurostima gounelleana (Beauv.) Men. (Velloziaceae) and Fernseea itatiaiae (Wawra) Baker (Bromeliaceae) - play a crucial role in this vegetation, as pioneer mat-formers facilitating later establishment of numerous other species. Hemicryptophytes prevail in the sampled flora, while therophytes are exceptionally rare and mainly consist of opportunistic species associated with disturbances. Numerous microhabitats and strong environmental gradients in these high elevation rock outcrops afford opportunities for establishment of a highly diversified flora. These island-like environments may represent an important refuge for grassland species from fire and other disturbances in the surrounding grasslands.
Resumo:
Independence among channels processing different aspects of spatial information, including orthogonal stimuli, has been generally assumed in the literature. We tested independence between the processing of jo targets and the processing of either vertical sinusoidal gratings or angular frequency stimuli with suprathreshold summation. We found the detection of a jo target at 1 cpd to be affected in an inhibitory fashion by either background angular frequencies in the range of 3-96 cycles or sinewave gratings in the range of 0.8-3.0 cpd. These results demonstrate interactions both among orthogonal stimuli and among channels processing vertical sinewave gratings and jo target stimuli. Our discussion focuses on the hypothesis of frequency decomposition in polar coordinates
Resumo:
Techniques for collecting exhaled nitric oxide (ENO) recommend the use of antibacterial filters of 0.3 µm. The aim of the present study was to compare the measurements of ENO obtained with two different filtering devices. Air samples from 17 asthmatic and 17 non-asthmatic subjects were collected by a recommended off-line technique using two different mouthpieces: 1) the Sievers disposable tool (A) under a breathing pressure of 18 cmH2O, and 2) a mouthpiece containing a HEPA filter (B) under a breathing pressure of 12 cmH2O. The nitric oxide samples were collected into an impermeable reservoir bag. Values for ENO were compared using two-way repeated measures ANOVA followed by the Tukey test. Agreement was assessed by Bland-Altman analysis. ENO values obtained with mouthpieces A and B were comparable for asthmatic (mean ± SEM, 42.9 ± 6.9 vs 43.3 ± 6.6 ppb) and non-asthmatic (13.3 ± 1.3 vs 13.7 ± 1.1 ppb) subjects. There was a significant difference in ENO between asthmatics and non-asthmatics using either mouthpiece A (P<0.001) or B (P<0.001). There was a positive correlation between mouthpiece A and mouthpiece B for both groups. The Bland-Altman limits of agreement were considered to be acceptable. Mouthpiece B was less expensive than A, and these data show that it can be used without compromising the result. Our data confirm reports of higher ENO values in the presence of airway inflammation.
Resumo:
Ventricular late potentials are low-amplitude signals originating from damaged myocardium and detected on the body surface by ECG filtering and averaging. Digital filters present in commercial equipment may interfere with the ability of arrhythmia stratification. We compared 40-Hz BiSpec (BI) and classical 40- to 250-Hz band-pass Butterworth bidirectional (BD) filters in terms of impact on time domain variables and diagnostic properties. In a transverse retrospective age-adjusted case-control study, 221 subjects with sinus rhythm without bundle branch block were divided into three groups after signal-averaged ECG acquisition: GI (N = 40), clinically normal controls, GII (N = 158), subjects with coronary heart disease without sustained monomorphic ventricular tachycardia (SMVT), and GIII (N = 23), subjects with heart disease and documented SMVT. Conventional variables analyzed from vector magnitude data after averaging to 0.3 µV final noise were obtained by application of each filter to the averaged signal, and evaluated in pairs by numerical comparison and by diagnostic agreement assessment, using conventional and optimized thresholds of normality. Significant differences were found between BI and BD variables in all groups, with diagnostic results showing significant disagreement between both filters [kappa value of 0.61 (P<0.05) for GII and 0.31 for GIII (P = NS)]. Sensitivity for SMVT was lower with BI than with BD (65.2 vs 91.3%, respectively, P<0.05). Filters provided significantly different numerical and diagnostic results and the BI filter showed only limited clinical application to risk stratification of ventricular arrhythmia.
Resumo:
Many studies have attempted to evaluate the importance of airborne fungi in the development of invasive fungal infection, especially for immunocompromised hosts. Several kinds of instruments are available to quantitate fungal propagule levels in air. We compared the performance of the most frequently used air sampler, the Andersen sampler with six stages, with a portable one, the Reuter centrifugal sampler (RCS). A total of 84 samples were analyzed, 42 with each sampler. Twenty-eight different fungal genera were identified in samples analyzed with the Andersen instrument. In samples obtained with the RCS only seven different fungal genera were identified. The three most frequently isolated genera in samples analyzed with both devices were Penicillium, Aspergillus and Cladophialophora. In areas supplied with a high efficiency particulate air filter, fungal spore levels were usually lower when compared to areas without these filters. There was a significant correlation between total fungal propagule measurements taken with both devices on each sampling occasion (Pearson coefficient = 0.50). However, the Andersen device recovered a broader spectrum of fungi. We conclude that the RCS can be used for quantitative estimates of airborne microbiological concentrations. For qualitative studies, however, this device cannot be recommended.
Resumo:
An assumption commonly made in the study of visual perception is that the lower the contrast threshold for a given stimulus, the more sensitive and selective will be the mechanism that processes it. On the basis of this consideration, we investigated contrast thresholds for two classes of stimuli: sine-wave gratings and radial frequency stimuli (i.e., j0 targets or stimuli modulated by spherical Bessel functions). Employing a suprathreshold summation method, we measured the selectivity of spatial and radial frequency filters using either sine-wave gratings or j0 target contrast profiles at either 1 or 4 cycles per degree of visual angle (cpd), as the test frequencies. Thus, in a forced-choice trial, observers chose between a background spatial (or radial) frequency alone and the given background stimulus plus the test frequency (1 or 4 cpd sine-wave grating or radial frequency). Contrary to our expectations, the results showed elevated thresholds (i.e., inhibition) for sine-wave gratings and decreased thresholds (i.e., summation) for radial frequencies when background and test frequencies were identical. This was true for both 1- and 4-cpd test frequencies. This finding suggests that sine-wave gratings and radial frequency stimuli are processed by different quasi-linear systems, one working at low luminance and contrast level (sine-wave gratings) and the other at high luminance and contrast levels (radial frequency stimuli). We think that this interpretation is consistent with distinct foveal only and foveal-parafoveal mechanisms involving striate and/or other higher visual areas (i.e., V2 and V4).
Resumo:
The mechanisms by which PM2.5 increases cardiovascular mortality are not fully identified. Autonomic alterations are the current main hypotheses. Our objective was to determine if PM2.5 induces acute cardiac polarization alterations in healthy Wistar rats. PM2.5 samples were collected on polycarbonate filters. Solutions containing 10, 20, and 50 µg PM2.5 were administered by tracheal instillation. P wave duration decreased significantly at 20 µg (0.99 ± 0.06, 0.95 ± 0.06, and 0.96 ± 0.07; P < 0.001), and 50 µg (0.98 ± 0.06, 0.98 ± 0.07, and 0.96 ± 0.08; 60, 90 and 120 min, respectively) compared to blank filter solution (P < 0.001). PR interval duration decreased significantly at 20 µg (0.99 ± 0.06, 0.98 ± 0.07, and 0.97 ± 0.08) and 50 µg (0.99 ± 0.05, 0.97 ± 0.0, and 0.95 ± 0.05; 60, 90, and 120 min, respectively) compared to blank filter and 10 µg (P < 0.001). QRS interval duration decreased at 20 and 50 µg in relation to blank filter solution and 10 µg (P < 0.001). QT interval duration decreased significantly (P < 0.001) with time in animals receiving 20 µg (0.94 ± 0.12, 0.88 ± 0.14, and 0.88 ± 0.11) and 50 µg (1.00 ± 0.13; 0.97 ± 0.11 and 0.98 ± 0.16; 60, 90 and 120 min, respectively) compared to blank filter solution and 10 µg (P < 0.001). PM2.5 induced reduced cardiac conduction time, within a short period, indicating that depolarization occurs more rapidly across ventricular tissue.
Resumo:
The objectives of this study were to determine the effect of tumor necrosis factor alpha (TNF-α) on intestinal epithelial cell permeability and the expression of tight junction proteins. Caco-2 cells were plated onto Transwell® microporous filters and treated with TNF-α (10 or 100 ng/mL) for 0, 4, 8, 16, or 24 h. The transepithelial electrical resistance and the mucosal-to-serosal flux rates of the established paracellular marker Lucifer yellow were measured in filter-grown monolayers of Caco-2 intestinal cells. The localization and expression of the tight junction protein occludin were detected by immunofluorescence and Western blot analysis, respectively. SYBR-Green-based real-time PCR was used to measure the expression of occludin mRNA. TNF-α treatment produced concentration- and time-dependent decreases in Caco-2 transepithelial resistance and increases in transepithelial permeability to the paracellular marker Lucifer yellow. Western blot results indicated that TNF-α decreased the expression of phosphorylated occludin in detergent-insoluble fractions but did not affect the expression of non-phosphorylated occludin protein. Real-time RT-PCR data showed that TNF-α did not affect the expression of occludin mRNA. Taken together, our data demonstrate that TNF-α increases Caco-2 monolayer permeability, decreases occludin protein expression and disturbs intercellular junctions.
Resumo:
Sugarcane spirit is a drink considered as a national symbol of Brazil. It is produced by large producers and by about 30 thousand small and medium home-distilling producers dispersed throughout the country. The copper originating from the home-distillers can become a serious problem since at high concentrations in beverages it may cause serious human health problems. Therefore, the objective of this study was to investigate the influence of the activated carbon used in commercial filters on the physicochemical and sensory characteristics of aged sugarcane spirit. Analyses of copper, dry extract, alcoholic degree, higher alcohols, volatile acids, aldehydes, esters, furfural, and methanol were performed. The sensory evaluation was performed by seven selected trained judges, who analyzed the yellow color, woody aroma and flavor, and intensity of alcoholic aroma and flavor of the cane spirit before and after the filtration process. The sensory tests were carried out using a 9 cm non-structured intensity scale. A reduction was observed in all compounds analyzed physicochemically, except for the esters, which increased after filtration. This increase is probably due to the esterification of the alcohols and acids present. According to the sensory results obtained, a reduction was observed in the intensity of the yellow color, aroma, and wood flavor characteristics, the major characteristics of the aging process.