73 resultados para False-door


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The clinical application of CCR5 antagonists involves first determining the coreceptor usage by the infecting viral strain. Bioinformatics programs that predict coreceptor usage could provide an alternative method to screen candidates for treatment with CCR5 antagonists, particularly in countries with limited financial resources. Thus, the present study aims to identify the best approach using bioinformatics tools for determining HIV-1 coreceptor usage in clinical practice. Proviral DNA sequences and Trofile results from 99 HIV-1-infected subjects under clinical monitoring were analyzed in this study. Based on the Trofile results, the viral variants present were 81.1% R5, 21.4% R5X4 and 1.8% X4. Determination of tropism using a Geno2pheno[coreceptor] analysis with a false positive rate of 10% gave the most suitable performance in this sampling: the R5 and X4 strains were found at frequencies of 78.5% and 28.4%, respectively, and there was 78.6% concordance between the phenotypic and genotypic results. Further studies are needed to clarify how genetic diversity amongst virus strains affects bioinformatics-driven approaches for determining tropism. Although this strategy could be useful for screening patients in developing countries, some limitations remain that restrict the wider application of coreceptor usage tests in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Candida albicans is often isolated from clinical samples, thus its presumptive differentiation from other species of the same genus can be based on its ability to form the germ tube in human serum. Nevertheless, there are two other species that share this characteristic: C. dubliniensis and C. africana. The aim of this study was to compare four different substrates to perform the germ tube (GT) test. The Candida spp. isolates were identified using a manual system (135 C. albicans, 24 C. tropicalis and one C. dubliniensis). The germ tube test was performed with fresh, previously frozen serum and Mueller-Hinton (MH) broth and agar. GT was observed in 96% (130/136) of the isolates through the fresh serum technique, 94% (128/136) through previously frozen serum, 92% (125/136) in MH agar, and 90% (122/136) in MH broth. The sensitivity of each test was higher than 90%, with 100% specificity. Both the MH agar and broth were able to identify the true positives, and false positives were not found. However, some C. albicans isolates were not identified. MH agar and broth may be used in laboratory for the rapid presumptive identification of C. albicans, as an alternative method for germ tube test.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Canine brains infected with rabies virus were submitted to decomposition by being left at room temperature of 25 to 29oC for up to 168h. At 24h intervals, brain fragments were analyzed by immunofluorescence (IF) and by the mouse intracerebral inoculation (MI) test to confirm the diagnosis of rabies and to measure the putrefaction effect on the accuracy of the diagnosis. Forty eight h after the beginning of the experiment, the MI test showed signs of impairment with four negative results, while after 72h, 100% of the results were negative to the MI test and only one result was negative to the IF test, indicating that the threshold period for accurate diagnosis is 24 to 48h before putrefaction. The authors recommend the shipment of suspected cases of rabies to the laboratory for confirmation, but the use of putrid materials for diagnosis is meaningless because of false-negative results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Forty voluntary blood donors from two different blood banks in Havana, Cuba, who were repeatedly reactive on the routine screening of antibodies to hepatitis C virus, by Umelisa HCV test, were analyzed for the presence of HCV RNA using a nested PCR assay of the HCV 5' untranslated region, Umelosa HCV qualitative. Sera from 45 patients of a specialized gastroenterology consultation, positive to Umelisa HCV, were also assayed with the Umelosa HCV qualitative, to establish their condition related to the presence of HCV RNA previously to the indication of a treatment or after three, six or twelve months of antiviral therapy. Serum HCV-RNA was detected in 21/40 (52.5%) donors who had repeatedly positive ELISA results, confirming the HCV infection for them. In specialized consultation HCV-RNA was detected by PCR analysis in 30/45 (66%) analyzed sera.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: To review measles IgM-positive cases of febrile rash illnesses in the State of São Paulo, Brazil, over the five-year period following interruption of measles virus transmission. METHODS: We reviewed 463 measles IgM-positive cases of febrile rash illness in the State of São Paulo, from 2000 to 2004. Individuals vaccinated against measles < 56 days prior to specimen collection were considered to be exposed to the vaccine. Serum from the acute and convalescent phases was tested for evidence of measles, rubella, parvovirus B19 and human herpes virus-6 infection. In the absence of seroconversion to measles immunoglobulin-G, measles IgM-positive cases were considered false positives in individuals with evidence of other viral infections. RESULTS: Among the 463 individuals with febrile rash illness who tested positive for measles IgM antibodies during the period, 297 (64%) were classified as exposed to the vaccine. Among the 166 cases that were not exposed to the vaccine, 109 (66%) were considered false positives based on the absence of seroconversion, among which 21 (13%) had evidence of rubella virus infection, 49 (30%) parvovirus B19 and 28 (17%) human herpes virus-6 infection. CONCLUSIONS: Following the interruption of measles virus transmission, thorough investigation of measles IgM-positive cases is required, especially among cases not exposed to the vaccine. Laboratory testing for etiologies of febrile rash illness aids interpretation of these cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Human T cell lymphotropic virus types 1 and 2 (HTLV-1/2) are endemic in Brazil and are screened for in transfusion services since 1993. This study evaluated the evolution of the prevalence of HTLV-1 and 2 in blood donors of the Hemominas Foundation from 1993 to 2007, and its geographical distribution in State of Minas Gerais, Brazil. METHODS: The Hemominas Foundation is a centralized blood center in Minas Gerais, Brazil. The sources of data were the Hemominas Foundation Technical Bulletin and files from the centralized serological laboratory. Donors were tested in the period using enzyme linked immuno sorbent assays (ELISA), followed by Western blot, when repeatedly reactive. The data were analyzed by EPIINFO 6.2 and TABWIN 3.5 softwares. RESULTS: The average seroprevalence in the period 1993-2007 was 0.1%. A steady decline occurred from 0.4% in 1993 to below 0.1% in 2002 and later, with a transient peak of 0.5% in 1994. HTLV reactivity distribution was asymmetrical in the state, with regions of higher prevalence, interspersed with low prevalence areas. Comparison of positive and negative donors verified that increasing age was proportional to virus positivity. Odds ratio for age ranged from 1.43 (30 to 39 years-old) to 3.09 (50 to 65 years-old). Women had a greater chance of being positive (OR-1.64), as previously described. CONCLUSIONS: Possible explanations for HTLV-1/2 prevalence decline are the exclusion of positive donors from the donor pool, an increase in repeat donors and ELISA test improvement, with reduction in the number of false positive results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Few Latin American studies have assessed the prevalence of hepatitis C virus (HCV) infection in elderly individuals, in whom the highest rates are expected. We aimed to investigate the prevalence of and factors associated with HCV infection in elderly residents in the municipality of Tubarão, Santa Catarina. Methods This cross-sectional study included 820 individuals (aged ≥ 60 years) who were selected by simple random sampling. The presence of anti-HCV antibodies was tested by chemiluminescence, and HCV RNA detection was performed for the anti-HCV-reactive subjects. Those individuals who were anti-HCV reactive but had undetectable HCV RNA levels were tested using a third-generation recombinant immunoblot assay. The variables were compared using the chi-squared test or Fisher's exact test, and those variables with p < 0.05 were included in the logistic regression model. Results The mean patient age was 68.6 years (SD 7.0 years); 39% were men, and 92% were Caucasian. Eighteen subjects were anti-HCV positive. Among these individuals, 4 were characterized as false-positives, leaving 14 (1.7%) individuals with confirmed infections for analysis. HCV infection was associated with an age older than 65 years, households with 3 or more residents and the previous transfusion of blood products. In the logistic regression analysis, the following variables were independently associated with HCV infection: households with 3 or more residents (OR 7.9, 95% CI 1.7–35.9, p = 0.008) and previous blood transfusion (OR 6.2, 95% CI 2.1–18.6, p = 0.001). Conclusions The HCV prevalence in the elderly population in the municipality of Tubarão was higher than that found in previous studies of blood donors in the same region. Although exposure to contaminated blood products remained important, other transmission routes, such as household transmission, could play a role in HCV infection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Toxoplasmosis may be life-threatening in fetuses and in immune-deficient patients. Conventional laboratory diagnosis of toxoplasmosis is based on the presence of IgM and IgG anti-Toxoplasma gondii antibodies; however, molecular techniques have emerged as alternative tools due to their increased sensitivity. The aim of this study was to compare the performance of 4 PCR-based methods for the laboratory diagnosis of toxoplasmosis. One hundred pregnant women who seroconverted during pregnancy were included in the study. The definition of cases was based on a 12-month follow-up of the infants. Methods Amniotic fluid samples were submitted to DNA extraction and amplification by the following 4 Toxoplasma techniques performed with parasite B1 gene primers: conventional PCR, nested-PCR, multiplex-nested-PCR, and real-time PCR. Seven parameters were analyzed, sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), negative likelihood ratio (NLR) and efficiency (Ef). Results Fifty-nine of the 100 infants had toxoplasmosis; 42 (71.2%) had IgM antibodies at birth but were asymptomatic, and the remaining 17 cases had non-detectable IgM antibodies but high IgG antibody titers that were associated with retinochoroiditis in 8 (13.5%) cases, abnormal cranial ultrasound in 5 (8.5%) cases, and signs/symptoms suggestive of infection in 4 (6.8%) cases. The conventional PCR assay detected 50 cases (9 false-negatives), nested-PCR detected 58 cases (1 false-negative and 4 false-positives), multiplex-nested-PCR detected 57 cases (2 false-negatives), and real-time-PCR detected 58 cases (1 false-negative). Conclusions The real-time PCR assay was the best-performing technique based on the parameters of Se (98.3%), Sp (100%), PPV (100%), NPV (97.6%), PLR (∞), NLR (0.017), and Ef (99%).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Despite the known importance of Clostridium difficile as a nosocomial pathogen, few studies regarding Clostridium difficile infection (CDI) in Brazil have been conducted. To date, the diagnostic tests that are available on the Brazilian market for the diagnosis of CDI have not been evaluated. The aim of this study was to compare the performances of four commercial methods for the diagnosis of CDI in patients from a university hospital in Brazil. Methods Three enzyme immunoassays (EIAs) and one nucleic acid amplification test (NAAT) were evaluated against a cytotoxicity assay (CTA) and toxigenic culture (TC). Stool samples from 92 patients with suspected CDI were used in this study. Results Twenty-five (27.2%) of 92 samples were positive according to the CTA, and 23 (25%) were positive according to the TC. All EIAs and the NAAT test demonstrated sensitivities between 59 and 68% and specificities greater than 91%. Conclusions All four methods exhibited low sensitivities for the diagnosis of CDI, which could lead to a large number of false-negative results, an increased risk of cross-infection to other patients, and overtreatment with empirical antibiotics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACTINTRODUCTION:Since women are frequently the minority among blood donors worldwide, studies evaluating this population usually reflect male features. We assessed the features of female blood donors with positive serology for HBV and compared them with those of men.METHODS The study comprised consecutive blood donors referred to a specialized liver disease center to be evaluated due to HBsAg- and/or anti-HBc-positive tests.RESULTS: The study encompassed 1,273 individuals, 219 (17.2%) of whom were referred due to positive HBsAg test and 1,054 (82.8%) due to reactive anti-HBc test. Subjects' mean age was 36.8±10.9 years, and 28.7% were women. Female blood donors referred for positive HBsAg screening tests demonstrated higher prevalence of healthcare workers (9.3% vs 2.5%) and lower prevalence of sexual risk behaviors (15.1% vs 41.1%) and alcohol abuse (1.9% vs 19.8%) compared to men. Women had lower ALT (0.6 vs 0.8×ULN), AST (0.6 vs 0.8×ULN), direct bilirubin (0.2 vs 0.3mg/dL), and alkaline phosphatase (0.5 vs 0.6×ULN) levels and higher platelet count (223,380±50,293 vs 195,020±53,060/mm3). Women also had a higher prevalence of false-positive results (29.6% vs 17.0%). No differences were observed with respect to liver biopsies. Female blood donors referenced for reactive anti-HBc screening tests presented similar clinical, epidemiological, and biochemical characteristics to those reported for positive HBsAg screening tests and similarly had a higher prevalence of false-reactive results.CONCLUSIONS: Compared to men, female blood donors with positive HBsAg and/or anti-HBc screening tests demonstrated higher prevalence of professional risk and false-positive results and reduced alteration of liver chemistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aims of this study were to evaluate the role of high resolution computed tomography of the torax in detecting abnormalities in chronic asthmatic patients and to determine the behavior of these lesions after at least one year. METHOD: Fourteen persistent asthmatic patients with a mean forced expiratory volume in 1-second that was 63% of predicted and a mean forced expiratory volume in 1-second /forced vital capacity of 60% had two high resolution computed tomographys separated by an interval of at least one year. RESULTS: All 14 patients had abnormalities on both scans. The most common abnormality was bronchial wall thickening, which was present in all patients on both computed tomographys. Bronchiectasis was suggested on the first computed tomography in 5 of the 14 (36%) patients, but on follow-up, the bronchial dilatation had disappeared in 2 and diminished in a third. Only one patient had any emphysematous changes; a minimal persistent area of paraseptal emphysema was present on both scans. In 3 patients, a "mosaic" appearance was observed on the first scan, and this persisted on the follow-up computed tomography. Two patients had persistent areas of mucoid impaction. In a third patient, mucus plugging was detected only on the second computed tomography. CONCLUSIONS: We conclude that there are many abnormalities on the high resolution computed tomography of patients with persistent asthma. Changes suggestive of bronchiectasis, namely bronchial dilatation, frequently resolve spontaneously. Therefore, the diagnosis of bronchiectasis by high resolution computed tomography in asthmatic patients must be made with caution, since bronchial dilatation can be reversible or can represent false dilatation. Nonsmoking chronic asthmatic subjects in this study had no evidence of centrilobular or panacinar emphysema.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article aims to describe important points in the history of panic disorder concept, as well as to highlight the importance of its diagnosis for clinical and research developments. Panic disorder has been described in several literary reports and folklore. One of the oldest examples lies in Greek mythology - the god Pan, responsible for the term panic. The first half of the 19th century witnessed the culmination of medical approach. During the second half of the 19th century came the psychological approach of anxiety. The 20th century associated panic disorder to hereditary, organic and psychological factors, dividing anxiety into simple and phobic anxious states. Therapeutic development was also observed in psychopharmacological and psychotherapeutic fields. Official classifications began to include panic disorder as a category since the third edition of the American Classification Manual (1980). Some biological theories dealing with etiology were widely discussed during the last decades of the 20th century. They were based on laboratory studies of physiological, cognitive and biochemical tests, as the false suffocation alarm theory and the fear network. Such theories were important in creating new diagnostic paradigms to modern psychiatry. That suggests the need to consider a wide range of historical variables to understand how particular features for panic disorder diagnosis have been developed and how treatment has emerged.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To test the feasibility, safety and accuracy of the adenosine protocol in the study of myocardial perfusion with microbubbles contrast echocardiography. METHODS: 81 pts (64 male, 60+11 years) were submitted to contrast echocardiography with PESDA (sonicated solution of albumin 20%-1ml, dextrose 5%-12ml and deca-fluorobutane gas-8ml) to study the myocardial perfusion at rest and after bolus injection of adenosine (6 to 18mg) and to coronary angiography within 1 month each other. For each patient 3 left ventricle perfusion beds were considered (total of 243 territories). 208 territories were analyzed and 35 territories were excluded. PESDA was continuously infused (1-2ml/min), titrated for best myocardial contrast. Triggered (1:1) second harmonic imaging was used. RESULTS: Coronary angiography showed 70 flow limiting (> 75%) lesions and 138 no flow limiting lesions. At rest an obvious myocardium contrast enhancement was seen in at least 1 segment of a territory in all patients. After adenosine injection an unquestionable further increase in myocardial contrast was observed in 136 territories (99%) related to no flow limiting lesions, lasting < 10 s, and a myocardial perfusion defect was detected in 68 territories (97%) related to flow limiting lesions. It was observed only 4 false results. There were no serious complications. CONCLUSION: Myocardial perfusion study with PESDA and adenosine protocol is a practical, safe and accurate method to analyze the coronary flow reserve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To identify the left inferior pulmonary vein as an indirect marker of increased pulmonary flow in congenital heart diseases.METHODS: We carried out a prospective consecutive study on 40 patients divided into 2 groups as follows: G1 - 20 patients diagnosed with congenital heart disease and increased pulmonary flow; G2 (control group) - 20 patients who were either healthy or had congenital heart disease with decreased or normal pulmonary flow. We obtained the velocity-time integral of the left inferior pulmonary vein flow, excluding the "reverse A" wave, with pulsed Doppler echocardiography.RESULTS: In G1, 19 out of the 20 patients had well-identified dilation of the left inferior pulmonary vein. No G2 patient had dilation of the left inferior pulmonary vein. Dilation of the left inferior pulmonary vein in conditions of increased pulmonary flow had sensitivity of 95%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 95% (1 false-negative case). The integral of time and velocity of the pulmonary venous flow obtained with pulsed Doppler echocardiography was greater in the G1 patients (G1=25.0±4.6 cm versus G2=14.8±2.1 cm, p=0.0001).CONCLUSION: The identification of dilation of the left inferior pulmonary vein suggests the presence of congenital heart disease with increased pulmonary flow. This may be used as an indirect sign of increased flow, mainly in malformations of difficult diagnosis, such as atrial septal defects of the venous sinus or coronary sinus type.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The flowers of this orchard tree presents six fleshy petals, fused two by two, and disposed propeller like. In the center is a cavity which harbors the cone shaped reproductive organs. An eriophyid mite, described by H. H. Keifer as Aculops flechtmann Keifer, 1972, causes considerable bronzing to the petals (Fig. 1-A). Large numbers of this mite attacking the basis of the reproductive organs causes them to dry and drop. On the young fruits, which are squamous, this mite causes some rusting and small necrotic areas (Fig. 1-B). As the fruit grows these small areas remain dark and barky. Very often the necrotic areas are invaded by the false spider mite Brevipalpus phoenicis (Geijskes, 1939), which enlarges the damage. The false spider mite also attacks leaves and green stems; the epidermis of the latter then assumes a barky appearance.