45 resultados para Event Procedure
Resumo:
A method based on matrix solid-phase dispersion and gas chromatography-mass spectrometry to determine procymidone, malathion, bifenthrin and pirimicarb in honey is described. The best results were obtained using 1.0 g of honey, 1.0 g of silica-gel as dispersant sorbent and acetonitrile as eluting solvent. The method was validated by fortified honey samples at three concentration levels (0.2, 0.5 to 1.0 mg kg-1). Average recoveries (n=7) ranged from 54 to 84%, with relative standard deviations between 3.7 and 8.5%. Detection and quantification limits attained by the developed method ranged from 0.02 to 0.08 mg kg-1 and 0.07 to 0.25 mg kg-1 for the honey, respectively.
Resumo:
A RP-HPLC procedure for the simultaneous determination of cisplatin and the complex cis,cis,trans-diamminedichlorodihydroxo-platinum(IV), was development. The developed procedure was validated in terms of linearity, accuracy, precision, limits of detection (LOD), limits of quantification (LOQ) and specificity. The limits of detection (LOD) were 0.47 x 10-4 and 0.53 x 10-4 mol L-1 and the limits of quantification (LOQ) were 1.57 x 10-4 and 1.75 x 10-4 mol L-1, for cisplatin and cis,cis,trans-diamminedichlorodihydroxopla-tinum(IV), respectively. The average recoveries of cisplatin and cis,cis,trans-diamminedichlorodihydroxoplatinum(IV) was 100.6% ± 1.4 and 101.2% ± 1.1, respectively. Intermediate (inter-day) precision, repeatability and specificity of the procedure for hydrolysis products of cisplatin were studied. The results of the study showed that the proposed RP-HPLC procedure is simple, rapid, precise, accurate and specific.
Resumo:
An evaluation of the pesticides extracted from the soil matrix was conducted using a citrate-buffered solid phase dispersion sample preparation method (QuEChERS). The identification and quantitation of pesticide compounds was performed using gas chromatography-mass spectrometry. Because of the occurrence of the matrix effect in 87% of the analyzed pesticides, the quantification was performed using matrix-matched calibration. The method's quantification limits were between 0.01 and 0.5 mg kg-1. Repeatability and intermediate precision, expressed as a relative standard deviation percentage, were less than 20%. The recoveries in general ranged between 62% and 99%, with a relative standard deviation < 20%. All the responses were linear, with a correlation coefficient (r) ≥0.99.
Resumo:
Some aspects of the application of electrochemical impedance spectroscopy to studies of solid electrode / solution interface, in the absence of faradaic processes, are analysed. In order to perform this analysis, gold electrodes with (111) and (210) crystallographic orientations in an aqueous solution containing 10 mmol dm-3 KF, as supporting electrolyte, and a pyridine concentration varying from 0.01 to 4.6 mmol dm-3, were used. The experimental data was analysed by using EQUIVCRT software, which utilises non-linear least squares routines, attributing to the solid electrode / solution interface behaviour described by an equivalent circuit with a resistance in series with a constant phase element. The results of this fitting procedure were analysed by the dependence on the electrode potential on two parameters: the pre-exponential factor, Y0, and the exponent n f, related with the phase angle shift. By this analysis it was possible to observe that the pyridine adsorption is strongly affected by the crystallographic orientation of the electrode surface and that the extent of deviation from ideal capacitive behaviour is mainly of interfacial origin.
Resumo:
In order to a better characterization of a graphite-polyurethane composite intended to be used as a voltammetric sensor, the performance in a square wave voltammetric procedure was investigated. Using hydroquinone (HQ) as a probe, the electrode showed to be useful in square wave voltammetry with limit of detection of 0.28 µmol L-1, with recoveries between 99.1 and 101.5%. The results of the proposed method agreed with HPLC ones within 95% confidence level.
Resumo:
A spectrophotometric flow injection method for the determination of paracetamol in pharmaceutical formulations is proposed. The procedure was based on the oxidation of paracetamol by sodium hypochloride and the determination of the excess of this oxidant using o-tolidine dichloride as chromogenic reagent at 430 nm. The analytical curve was linear in the paracetamol concentration range from 8.50 x 10-6 to 2.51 x 10-4 mol L-1 with a detection limit of 5.0 x 10-6 mol L-1. The relative standard deviation was smaller than 1.2% for 1.20 x 10-4 mol L-1 paracetamol solution (n = 10). The results obtained for paracetamol in pharmaceutical formulations using the proposed flow injection method and those obtained using a USP Pharmacopoeia method are in agreement at the 95% confidence level.
Resumo:
Late renal cell carcinoma recurrence in the renal fossa is a rare event. This condition occurs in 1 to 2% of radical nephrectomies. We reported a late recurrence at the renal fossa about four and half years after radical nephrectomy due to a renal cell carcinoma (RCC) without metastasis elsewhere. Diagnosis in an outpatient follow-up was made during an abdominal computed tomography and we observed a retroperitoneal mass in the renal fossa. The excision at the recurrence area was made through a subcostal transversal incision without any difficulty. After 6 months from this second procedure, there was no evidence of recurrence. The surgical aggressive treatment for late retroperitoneal RCC recurrence is a good method in this rare situation. Abdominal computed tomography must be done during long periods of follow-up for patients with radical nephrectomy for RCC to search for late retroperitoneal recurrences.
Resumo:
Objective: To evaluate the effectiveness and safety of correction of pectus excavatum by the Nuss technique based on the available scientific evidence.Methods: We conducted an evidence synthesis following systematic processes of search, selection, extraction and critical appraisal. Outcomes were classified by importance and had their quality assessed by the Grading of Recommendations Assessment, Development and Evaluation (GRADE).Results: The process of selection of items led to the inclusion of only one systematic review, which synthesized the results of nine observational studies comparing the Nuss and Ravitch procedures. The evidence found was rated as poor and very poor quality. The Nuss procedure has increased the incidence of hemothorax (RR = 5.15; 95% CI: 1.07; 24.89), pneumothorax (RR = 5.26; 95% CI: 1.55; 17.92) and the need for reintervention (RR = 4.88; 95% CI: 2.41; 9.88) when compared to the Ravitch. There was no statistical difference between the two procedures in outcomes: general complications, blood transfusion, hospital stay and time to ambulation. The Nuss operation was faster than the Ravitch (mean difference [MD] = -69.94 minutes, 95% CI: -139.04, -0.83).Conclusion: In the absence of well-designed prospective studies to clarify the evidence, especially in terms of aesthetics and quality of life, surgical indication should be individualized and the choice of the technique based on patient preference and experience of the team.
Resumo:
In the present study, using noise-free simulated signals, we performed a comparative examination of several preprocessing techniques that are used to transform the cardiac event series in a regularly sampled time series, appropriate for spectral analysis of heart rhythm variability (HRV). First, a group of noise-free simulated point event series, which represents a time series of heartbeats, was generated by an integral pulse frequency modulation model. In order to evaluate the performance of the preprocessing methods, the differences between the spectra of the preprocessed simulated signals and the true spectrum (spectrum of the model input modulating signals) were surveyed by visual analysis and by contrasting merit indices. It is desired that estimated spectra match the true spectrum as close as possible, showing a minimum of harmonic components and other artifacts. The merit indices proposed to quantify these mismatches were the leakage rate, defined as a measure of leakage components (located outside some narrow windows centered at frequencies of model input modulating signals) with respect to the whole spectral components, and the numbers of leakage components with amplitudes greater than 1%, 5% and 10% of the total spectral components. Our data, obtained from a noise-free simulation, indicate that the utilization of heart rate values instead of heart period values in the derivation of signals representative of heart rhythm results in more accurate spectra. Furthermore, our data support the efficiency of the widely used preprocessing technique based on the convolution of inverse interval function values with a rectangular window, and suggest the preprocessing technique based on a cubic polynomial interpolation of inverse interval function values and succeeding spectral analysis as another efficient and fast method for the analysis of HRV signals
Resumo:
Exclusion of the transcription factor Max from the nucleus of retinal ganglion cells is an early, caspase-independent event of programmed cell death following damage to the optic axons. To test whether the loss of nuclear Max leads to a reduction in neuroprotection, we developed a procedure to overexpress Max protein in rat retinal tissue in vivo. A recombinant adeno-associated viral vector (rAAV) containing the max gene was constructed, and its efficiency was confirmed by transduction of HEK-293 cells. Retinal ganglion cells were accessed in vivo through intravitreal injections of the vector in rats. Overexpression of Max in ganglion cells was detected by immunohistochemistry at 2 weeks following rAAV injection. In retinal explants, the preparation of which causes damage to the optic axons, Max immunoreactivity was increased after 30 h in vitro, and correlated with the preservation of a healthy morphology in ganglion cells. The data show that the rAAV vector efficiently expresses Max in mammalian retinal ganglion cells, and support the hypothesis that the Max protein plays a protective role for retinal neurons.
Resumo:
In order to detect several new HLA-A class I alleles that have been described since 1998, the original PCR-RFLP method developed to identify the 78 alleles recognized at that time at high resolution level was adapted by us for low and medium resolution levels using a nested PCR-RFLP approach. The results obtained from blood samples of 23 subjects using both the PCR-RFLP method and a commercial kit (MicroSSP1A®, One Lambda Inc.) showed an agreement higher than 95%. The PCR-RFLP adapted method was effective in low and medium resolution histocompatibility evaluations.
Resumo:
Patients with metabolic syndrome are at high-risk for development of atherosclerosis and cardiovascular events. The objective of this study was to examine the major determinants of coronary disease severity, including those coronary risk factors associated with metabolic syndrome, during the early period after an acute coronary episode. We tested the hypothesis that inflammatory markers, especially highly sensitive C-reactive protein (hsCRP), are related to coronary atherosclerosis, in addition to traditional coronary risk factors. Subjects of both genders aged 30 to 75 years (N = 116) were prospectively included if they had suffered a recent acute coronary syndrome (acute myocardial infarction or unstable angina pectoris requiring hospitalization) and if they had metabolic syndrome diagnosed according to the National Cholesterol Education Program/Adult Treatment Panel III. Patients were submitted to a coronary angiography and the burden of atherosclerosis was estimated by the Gensini score. The severity of coronary disease was correlated (Spearman’s or Pearson’s coefficient) with gender (r = 0.291, P = 0.008), age (r = 0.218, P = 0.048), hsCRP (r = 0.256, P = 0.020), ApoB/ApoA ratio (r = 0.233, P = 0.041), and carotid intima-media thickness (r = 0.236, P = 0.041). After multiple linear regression, only male gender (P = 0.046) and hsCRP (P = 0.012) remained independently associated with the Gensini score. In this high-risk population, male gender and high levels of hsCRP, two variables that can be easily obtained, were associated with more extensive coronary disease, identifying patients with the highest potential of developing new coronary events.
Resumo:
Affective states influence subsequent attention allocation. We evaluated emotional negativity bias modulation by reappraisal in patients with generalized anxiety disorder (GAD) relative to normal controls. Event-related potential (ERP) recordings were obtained, and changes in P200 and P300 amplitudes in response to negative or neutral words were noted after decreasing negative emotion or establishing a neutral condition. We found that in GAD patients only, the mean P200 amplitude after negative word presentation was much higher than after the presentation of neutral words. In normal controls, after downregulation of negative emotion, the mean P300 amplitude in response to negative words was much lower than after neutral words, and this was significant in both the left and right regions. In GAD patients, the negative bias remained prominent and was not affected by reappraisal at the early stage. Reappraisal was observed to have a lateralized effect at the late stage.
Resumo:
Transtracheal puncture has long been known as a safe, low-cost procedure. However, with the advent of bronchoscopy, it has largely been forgotten. Two researchers have suggested the use of α-amylase activity to diagnose salivary aspiration, but the normal values of this enzyme in tracheobronchial secretions are unknown. We aimed to define the normal values of α-amylase activity in tracheobronchial secretions and verify the rate of major complications of transtracheal puncture. From October 2009 to June 2011, we prospectively evaluated 118 patients without clinical or radiological signs of salivary aspiration who underwent transtracheal puncture before bronchoscopy. The patients were sedated with a solution of lidocaine and diazepam until they reached a Ramsay sedation score of 2 or 3. We then cleaned the cervical region and anesthetized the superficial planes with lidocaine. Next, we injected 10 mL of 2% lidocaine into the tracheobronchial tree. Finally, we injected 10 mL of normal saline into the tracheobronchial tree and immediately aspirated the saline with maximum vacuum pressure to collect samples for measurement of the α-amylase level. The α-amylase level mean ± SE, median, and range were 1914 ± 240, 1056, and 24-10,000 IU/L, respectively. No major complications (peripheral desaturation, subcutaneous emphysema, cardiac arrhythmia, or hemoptysis) occurred among 118 patients who underwent this procedure. Transtracheal aspiration is a safe, low-cost procedure. We herein define for the first time the normal α-amylase levels in the tracheobronchial secretions of humans.
Resumo:
Yerba maté extracts have in vitro antioxidant capacity attributed to the presence of polyphenolic compounds, mainly chlorogenic acids and dicaffeoylquinic acid derivatives. DPPH is one of the most used assays to measure the antioxidant capacity of pure compounds and plant extracts. It is difficult to compare the results between studies because this assay is applied in too many different conditions by the different research groups. Thus, in order to assess the antioxidant capacity of yerba maté extracts, the following procedure is proposed: 100 µL of an aqueous dilution of the extracts is mixed in duplicate with 3.0 mL of a DPPH 'work solution in absolute methanol (100 µM.L-1), with an incubation time of 120 minutes in darkness at 37 ± 1 °C, and then absorbance is read at 517 nm against absolute methanol. The results should be expressed as ascorbic acid equivalents or Trolox equivalents in mass percentage (g% dm, dry matter) in order to facilitate comparisons. The AOC of the ethanolic extracts ranged between 12.8 and 23.1 g TE % dm and from 9.1 to 16.4 g AAE % dm. The AOC determined by the DPPH assay proposed in the present study can be related to the total polyphenolic content determined by the Folin-Ciocalteu assay.