79 resultados para Descriptive quantitative analysis
Resumo:
Due to morphological similarities between Triatoma maculata and T. pseudomaculata, which comprise the "maculate complex", both had been regarded as the same species until 1964. Considering that the studies on triatomine hybridization permit hypotheses formulation concerning origin and divergence of species, enabling a quantitative analysis of taxonomic relationships between species, the present investigation was aimed at broadening further understanding related to the capacity of hybrid production by determining the degree of reproductive isolation between T. maculata and T. pseudomaculata. Our results have demonstrated that T. maculata and T. pseudomaculata showed no differences regarding reproduction patterns and they are able to cross, generating infertile hybrids.
Resumo:
Information underlying analyses of coffee fertilization systems should consider both the soil and the nutritional status of plants. This study investigated the spatial relationship between phosphorus (P) levels in coffee plant tissues and soil chemical and physical properties. The study was performed using two arabica and one canephora coffee variety. Sampling grids were established in the areas, and the points georeferenced. The assessed properties of the soil were levels of available phosphorus (P-Mehlich), remaining phosphorus (P-rem) and particle size, and of the plant tissue, phosphorus levels (foliar P). The data were subjected to descriptive statistical analysis, correlation analysis, cluster analysis, and probability tests. Geostatistical and trend analyses were only performed for pairs of variables with significant linear correlation. The spatial variability for foliar P content was high for the variety Catuai and medium for the other evaluated plants. Unlike P-Mehlich, the variability in P-rem of the soil indicated the nutritional status of this nutrient in the plant.
Resumo:
The objective of this work was to perform a quantitative analysis of the amino acid composition of soybean seeds as affected by climatic variables during seed filling. Amino acids were determined from seed samples taken at harvest in 31 multi-environment field trials carried out in Argentina. Total amino acids ranged from 31.69 to 49.14%, and total essential and nonessential amino acids varied from 12.83 to 19.02% and from 18.86 to 31.15%, respectively. Variance components expressed as the percentage of total variation showed that the environment was the most important source of variation for all traits, followed by the genotype x environment interaction. Significant explanatory linear regressions were detected for amino acid content regarding: average daily mean air temperature and cumulative solar radiation, during seed filling; precipitation minus potential evapotranspiration, during the whole reproductive period; and the combinations of these climatic variables. Each amino acid behaves differently according to environmental conditions, indicating compensatory effects among them.
Genetic diversity between improved banana diploids using canonical variables and the Ward-MLM method
Resumo:
The objective of this work was to estimate the genetic diversity of improved banana diploids using data from quantitative analysis and from simple sequence repeats (SSR) marker, simultaneously. The experiment was carried out with 33 diploids, in an augmented block design with 30 regular treatments and three common ones. Eighteen agronomic characteristics and 20 SSR primers were used. The agronomic characteristics and the SSR were analyzed simultaneously by the Ward-MLM, cluster, and IML procedures. The Ward clustering method considered the combined matrix obtained by the Gower algorithm. The Ward-MLM procedure identified three ideal groups (G1, G2, and G3) based on pseudo-F and pseudo-t² statistics. The dendrogram showed relative similarity between the G1 genotypes, justified by genealogy. In G2, 'Calcutta 4' appears in 62% of the genealogies. Similar behavior was observed in G3, in which the 028003-01 diploid is the male parent of the 086079-10 and 042079-06 genotypes. The method with canonical variables had greater discriminatory power than Ward-MLM. Although reduced, the genetic variability available is sufficient to be used in the development of new hybrids.
Resumo:
Objective To develop procedures to ensure consistency of printing quality of digital images, by means of hardcopy quantitative analysis based on a standard image. Materials and Methods Characteristics of mammography DI-ML and general purpose DI-HL films were studied through the QC-Test utilizing different processing techniques in a FujiFilm®-DryPix4000 printer. A software was developed for sensitometric evaluation, generating a digital image including a gray scale and a bar pattern to evaluate contrast and spatial resolution. Results Mammography films showed maximum optical density of 4.11 and general purpose films, 3.22. The digital image was developed with a 33-step wedge scale and a high-contrast bar pattern (1 to 30 lp/cm) for spatial resolution evaluation. Conclusion Mammographic films presented higher values for maximum optical density and contrast resolution as compared with general purpose films. The utilized digital processing technique could only change the image pixels matrix values and did not affect the printing standard. The proposed digital image standard allows greater control of the relationship between pixels values and optical density obtained in the analysis of films quality and printing systems.
Resumo:
Objective Quantitative analysis of chest radiographs of patients with and without chronic obstructive pulmonary disease (COPD) determining if the data obtained from such radiographic images could classify such individuals according to the presence or absence of disease. Materials and Methods For such a purpose, three groups of chest radiographic images were utilized, namely: group 1, including 25 individuals with COPD; group 2, including 27 individuals without COPD; and group 3 (utilized for the reclassification /validation of the analysis), including 15 individuals with COPD. The COPD classification was based on spirometry. The variables normalized by retrosternal height were the following: pulmonary width (LARGP); levels of right (ALBDIR) and left (ALBESQ) diaphragmatic eventration; costophrenic angle (ANGCF); and right (DISDIR) and left (DISESQ) intercostal distances. Results As the radiographic images of patients with and without COPD were compared, statistically significant differences were observed between the two groups on the variables related to the diaphragm. In the COPD reclassification the following variables presented the highest indices of correct classification: ANGCF (80%), ALBDIR (73.3%), ALBESQ (86.7%). Conclusion The radiographic assessment of the chest demonstrated that the variables related to the diaphragm allow a better differentiation between individuals with and without COPD.
Resumo:
A simple chemical method has been developed to quantify the silanol groups (º Si-OH) in silica as well as in coated chromatographic supports for use in packed - column Gas Chromatography. After adsorption of 10 mg/mL methylene blue, centrifuging action and filtration, the absorbance of the solution was inversely proportional to the silanol quantity. The difference between the absorbance of the pure solution and that of the solid - free filtrate was related to the silica weight, yielding a quantitative analysis of these groups.
Resumo:
This review presents the evolution of simultaneous multicomponent analysis by absorption spectrophotometry in the ultraviolet and visual regions in terms of some qualitative and quantitative analysis techniques, otimization methods, as well as applications and modern trends.
Resumo:
Crude extract of Tibouchina granulosa, Rhododendron simsii and Phaseolus vulgaris L. were prepared and used as alternative indicators in quantitative analysis teaching in standardization of NaOH solutions and in the determination of acetic acid contents in vinegar. Effect of using such natural extracts as indicators was very attractive to the students and the quantitative results were compared with conventional indicators with good agreement. Concepts of data statistics can successfully be discussed using the interest revived by the use of natural indicators.
Resumo:
One of the main problems in quantitative analysis of complex samples by x-ray fluorescence is related to interelemental (or matrix) effects. These effects appear as a result of interactions among sample elements, affecting the x-ray emission intensity in a non-linear manner. Basically, two main effects occur; intensity absorption and enhancement. The combination of these effects can lead to serious problems. Many studies have been carried out proposing mathematical methods to correct for these effects. Basic concepts and the main correction methods are discussed here.
Resumo:
Pesticide residues are determined by thin layer chromatography (TLC) using the Hill reaction as a detection method. Tomatoes samples without pesticide were fortified with atrazine, diuron, chloroxuron and metribuzin, and were applyed in silica gel plates with the help of a microsyringe. The pesticides were elued with ethyl acetate. There was no need of cleaning up because no interference was noticed. After the revelation of the plates, the diameters of the spots were measure by using a rule. The range of the determined concentration for all the pesticides was from 0.1 to1.0 ng/muL. The results obtained through TLC can be used for semi-quantitative analysis.The results obtained were compared to gas and liquid chromatography, showing good agreement between both techniques.
Resumo:
Samples of copper compounds covering all of the XXth century and the end of the XIXth century were submitted to classical and instrumental quantitative analysis. The amount of impurities greatly decreased with time, reaching a constant level since the 1960's. The gravimetric method was suitable for the determination of copper although other procedures also gave good or reasonable results. However, for metal contaminants, atomic absorption spectrometry was the best choice because of its lower detection limits, being able to determine several elements in the oldest samples. Ion chromatography detected several anions in copper salts manufactured before the 1950's. An increasing quality of raw materials and a better sensitivity of analytical methods led to quality improvement of copper compounds with time.
Resumo:
KBrO3 is registered by the FAO/OMS as a genotoxic and carcinogenic compound. In spite of this, KBrO3 is still employed by Brazilian bakeries. Nowadays ion exchange chromatography (IEC) is the most rapid and trustful method for BrO3- analysis. When at high concentrations, chloride ions can interfere in the BrO3- analysis, if the detection is performed by electrical conductivity. On the other hand, spectrophotometric detection, presented here is based on the absorption of BrO3- in the ultraviolet region (210 - 230 nm) where the absortion of chloride ions is very low, thus making possible the qualitative and quantitative analysis of BrO3- in flour improver samples.
Resumo:
The structural characterization of molecules used in the sterilization of blood for transfusions, such as crystal violet (CV), is relevant for understanding the action of these prophylactic drugs. The characterization is feasible by surface enhanced resonance Raman spectroscopy (SERRS) of CV in solution or on surfaces. The limit of detection of CV by SERRS, in the presence of colloidal particles, using 514.5 nm as excitation radiation, was found to be around 1 ppb. The characterization of CV was also made by SERS, by using different active-particles-containing substrates, proving the versatility of this technique for the study of such structures. The results suggest that the controlled production of highly efficient SERS-active substrates may allow qualitative and quantitative analysis, with high sensitivity, with potential applications in medical and environmental fields.
Resumo:
Coffee is one of the beverages most widely consumed in the world and the "cafezinho" is normally prepared from a blend of roasted powder of two species, Coffea arabica and Coffea canephora. Each one exhibits differences in their taste and in the chemical composition, especially in the caffeine percentage. There are several procedures proposed in the literature for caffeine determination in different samples like soft drinks, coffee, medicines, etc but most of them need a sample workup which involves at least one step of purification. This work describes the quantitative analysis of caffeine using ¹H NMR and the identification of the major components in commercial coffee samples using 1D and 2D NMR techniques without any sample pre-treatment.