76 resultados para DISPOSITIVOS DE CRISTALES LÍQUIDOS
Resumo:
This article proposes an experimental procedure to determine the enthalpy (and entropy) of vaporization of organic liquid compounds, by the Smith-Menzies (isoteniscope) method. The values of vapor pressure at different temperatures were obtained and ΔvH (and ΔvS) were graphically determined, using the Clausius-Clapeyron equation. The results for diethyl-ether, propanone, ethanol and n-hexane are in very good agreement with those from literature. A historical and thermodynamic discussion on equations that correlates vapor pressures and temperature precedes the experimental proposition.
Efecto del catión, del anión y del co-ión sobre la agregación de líquidos iónicos en solución acuosa
Resumo:
The aggregation behavior of thirteen 1-alkyl-3-methylimidazolium based ionic liquids in aqueous solution is presented, considering variations of the alkyl side chain length as well as the anionic moiety. Cation and anion molecular volumes are selected as appropriate molecular descriptors. Additionally, the existing relationship between critical micelle concentration (CMC) and electrolyte concentration in solution is established, aiming to clarify ion effects. CMC values were obtained by measuring electrical conductivity and surface tension. It was confirmed that aggregation of ionic liquids in aqueous solution and in presence of inorganic salts is affected by the factors developed in this study.
Resumo:
An UV-Ozone reactor was developed with an ignition tube extracted into HID mercury lamp used to irradiation on zinc oxide (ZnO) and fluorinated tin oxide (FTO) films for PLEDs devices. Different exposures times were used. In contact angle measurements revealed better results for ZnO and FTO by 15 and 5 min, respectively. In Diffuse Reflectance Infra-red Fourier Transformed (DRIFT) spectroscopy allowed the observation of water, hydrocarbon and carbon dioxide adsorbed on the untreated TCO surfaces. After the UV-Ozone treatment the contaminants were significantly reduced or eliminated and the PLEDs devices decreased threshold voltages in comparison with respectively untreated TCOs.
Incorporação de líquidos iônicos e nanopartículas metálicas na construção de sensores eletroquímicos
Resumo:
The most relevant advances on analytical applications of ionic liquids (IL) as binder in the construction of electrochemical sensors and biosensors based on carbon paste are presented. This new class of solvents - the IL - has received great attention in electroanalytical researches due to the excellent physical and chemical properties of these materials, such as high conductivity, low toxicity, good stability, large electrochemical window and catalytic ability. Recently, the interest in electrodes modified with IL, especially when combined with metallic nanoparticles, has increased expressively due to improve the sensitivity and others advantages discussed in this review.
Resumo:
This work studies the influence of the film deposition process on light emission performance and on threshold voltage of OLEDs, with architecture glass/ITO/PEDOT:PSS/PVK/Alq3/Al. The commercial PVK was dissolved in different solvents such as: chloroform, tetrahydrofuran, 1,2,4-trichlorobenzene and trimethylpentane. OLEDs were characterized by current-voltage and revealed a significant influence of the solvents, although all devices emitted green electroluminescence. A difference in threshold voltage up to 10 V was observed among OLEDs prepared from different solvents. The 1,2,4-trichlorobenzene showed best performance, presenting lowest treshold voltage (≈ 6 V), followed by tetrahydrofuran (≈ 8 V), trimethylpentane (≈ 14 V) and chloroform (≈ 16 V).
Resumo:
Shadow masks are used in manufacturing processes for electro-optic devices to transfer patterns with different shapes and dimensions. For fabrication of organic based devices, shadow masks should be made of materials stable against organic solvents, high temperature, and robust, remaining unchanged after multiple cycles of use and fixation. Thus, stainless steel is suitable for shadow masks. A simple, cheap and quick method of obtaining shadow masks by electrochemical corrosion of stainless steel is reported. The shadow mask was used to evaporate cathode material to obtain an organic light emitting diode with active area of 9 mm². This device exhibited a turn-on voltage of 5 V and luminance of 14 cd/m².
Resumo:
We describe a synthetic route consisting of five steps from aniline to obtain liquid crystal compounds derived from nitroazobenzene. Syntheses were performed during the second half of the semester in organic chemistry laboratory classes. Students characterized the liquid crystal phase by the standard melting point techniques, differential scanning calorimetry and polarized optical microscopy. These experiments allow undergraduate students to explore fundamentally important reactions in Organic Chemistry, as well as modern concepts in Chemistry such as self-assembly and self-organization, nanostructured materials and molecular electronics.
Resumo:
Two imidazolium-based ionic liquids (C4MIMTf2N and C4MIMBF4) were used to verify their influence on polyaniline (PANI) and nitrile rubber (NBR)/PANI blend properties and the vulcanization process. High conductivity values were observed for PANI-C4MIMTf2N samples and no interference was found for the C4MIMBF4 samples. These materials were added to NBR by mechanical mixing. Based on the torque results, the presence of C4MIMBF4 does not protect the vulcanization reaction of NBR with PANI as performed by C4MIMTf2N. The highest conductivity value was obtained with 7 wt. % of PANI-DSBA-C4MIMTf2N (10-6 S/cm). This result is attributed to the more effective interaction of PANI and NBR phases promoted by the ionic liquid.
Resumo:
This report describes a study about the feasibility of using a conventional digital camera, a cell-phone camera, an optical microscope, and a scanner as digital image capture devices on printed microzones. An array containing nine circular zones was drawn using graphics software and printed onto transparency film by a laser printer. Due to its superior analytical performance, the scanner was chosen for the quantitative determination of Fe2+ in pharmaceutical samples. The data achieved using scanned images did not differ statistically from those attained by the reference spectrophotometric method at the confidence level of 0.05.
Resumo:
The use of MT-K10 Montmorillonite immobilized onto agarose was investigated in this work as an alternative binding phase in Diffusive Gradient in Thin Film (DGT) devices for the determination of metallic labile species. In addition, agarose itself was also used as the diffusive phase. The percentage of sorption of Zn2+, Cu2+, Cr3+, Mn2+, Cd2+, Pb2+, and Ni2+ onto the binding phase was higher than 80% and the desorption process for all elements was also greater than 75%. Elution factors were determined experimentally, ranging from 0.74 for Zn2+ and 0.90 for Cr3+ and Pb2+. The accumulation of all species was linear with time, in agreement with the Fick's 1st law of diffusion. The deployment of the alternative devices in natural waters was compared to commercial devices. Labile concentrations determined by the alternative devices were slightly superior compared to results obtained with the deployment of original DGT devices due to the less restrictive pores of agarose.
Resumo:
Condensation reactions of glycerol with aldehydes and ketones were performed under thermal heating and microwave irradiation regimes. Homogeneous and heterogeneous catalysts were tested in both conditions. A silica sulfated (SiO2-SO3H) heterogeneous catalyst demonstrated the best performance relative to a selectivity of >95% in favor of 5-membered ketals. For acetals, preference in favor of 5-membered or 6-membered functional groups depends on the nature of the catalyst. Homogenous catalysts favor the more stable 6-membered acetals, whereas heterogeneous catalysts favor the less stable 5-membered acetals. However, the isomer ratios in the acetalization reaction are too low, and hence the reaction cannot be used in a synthetic plan for functional materials. Ketalization processes mediated by SiO2-SO3H show a high selectivity in favor of a 5-membered ring (1,3-dioxolane). The scope of condensation was tested with different ketones. A mechanism for heterogeneous catalysis related to the selectivity in the cyclization process is presented herein. Solketal, a commercial product, was also obtained by a condensation reaction of glycerol and propanone, and showed a high selectivity in favor of 1,3-dioxolane. It was transformed to potential allylic and chiral intermediates. A mesogenic core was connected to the organic framework of glycerol to produce a monomer liquid crystal material with a stable smectic-C mesophase.
Resumo:
This study describes the application of the Art of Scientific and Technological Search to strategically analyze areas of technological and industrial development. Application of scientific search strategies such as the creation of Patent Landscape has been shown to be useful for writing research projects, earning grants, publishing papers, drafting patent applications, and analyzing the market and economic potentials of a previous determined subject. The Patent Landscape regards a simplified analysis of technologies concerning ionic liquids patents applied in Brazil and published by Instituto Nacional da Propriedade Industrial(INPI). A total of 93 patent applications using the keywords "ionic liquids" were found in the INPI database. Among these, 75% were nonresident applications and 25% were Brazilian resident applications. Interestingly, BASF, Chevron Industries, and the Universidade Federal do Rio Grande do Sul (UFRGS) were discovered as higher patent applicant assignees. Differences in the patent application areas were also observed between these applicants, with new solvents and petrochemical applications as the areas of focus for the industrial applications (BASF and Chevron Industries), and energy production, catalysis, and chemical reaction media as the focus for the university applications.
Resumo:
In this work, we used an aqueous two-phase system (ATPS) consisting of the ionic liquid [C4mim][Cl] and the salt K2HPO4 to partition α-lactalbumin, β-lactoglobulin, and lactoferrin whey proteins. Extraction efficiency values above 87% indicate that the proteins primarily migrated to the ionic liquid-rich phase (top phase). Partition coefficient values ranged from 6.17 to 8.93 for a-lactalbumin, from 22.80 to 34.55 for β-lactoglobulin, and from 26.46 to 40.06 for lactoferrin. Therefore, the saline ATPS with the ionic liquid examined in this study can be considered to be a promising alternative for extracting whey proteins.
Resumo:
Since their original discovery in 1914, ionic liquids (IL) have been widely examined and explored in chemistry due to their unique physical and chemical properties. Ionic liquids are collectively known as organic salts and have melting points of 100 °C or under. The molten salts most employed in analytical chemistry, including gas chromatography (GC), consist of an organic cation paired with an organic or inorganic anion. This class of materials exhibits negligible vapor pressure and may have their properties (e.g.thermal stability and selectivity) structurally tuned by imparting different moieties to the cation/anion. Currently, there are an estimated 1018possible combinations of IL. In this context, the prospection of highly selective IL-based stationary phases for gas-liquid chromatography has enabled high peak capacity and efficient separations of many critical pairs in complex samples. In this review, we present and discuss fundamental characteristics of ionic liquids and introduce important solvation models for gas-liquid systems. In addition, recent advances and applications of IL in conventional and multidimensional gas chromatography are outlined.
Resumo:
O uso de adoçantes líquidos com sacarina sódica é uma questão de saúde pública pela relação com obesidade e fonte de sódio. Os níveis de sacarina foram avaliados em quatro marcas de diferentes fabricantes em amostras adquiridas no comércio de Vitória/ES, entre os anos de 2006 e 2008. Foram encontrados níveis com valores entre 260 e 505 vezes acima da Resolução-RDC N0 8, 25/03/2008 (ANVISA), que é de 0,015 g/100 mL para sacarina e seus sais derivados. O perfil das amostras cristalizadas dos adoçantes foram avaliados por espectroscopia na região do infravermelho e por difração de raio-X de pó. A seletividade do método clássico de precipitação com AgNO3 também foi verificada por essas técnicas aplicadas nos precipitados de sacarinato de prata.