277 resultados para BIOPROSTHETIC HEART-VALVES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate and compare the usefulness of cineventriculographies, before and after nitrate use, to technetium-99m sestamibi scintigraphy for the identification of myocardial ischemia. METHODS: Twenty-six patients were studied at basal conditions and 5 minutes after intravenous administration of isosorbide mononitrate (0.3mg/kg), to evaluate the performance and regional wall motion of the left ventricle (LV). The results were compared to those obtained with technetium-99m sestamibi scintigraphy. RESULTS: Before nitrate, contrast ventriculography identified 30 normal segments, 62 hypokinetic segments, 28 dyskinetic segments, and 14 akinetic segments. After drug administration, 99 segments were normal, 11 hypokinetic, 11 dyskinetic, and 13 akinetic. Myocardial scintigraphy revealed 110 ischemic segments and 18 fibrotic segments (p<0.005). After drug administration, the ventriculography showed increase in the velocity of circumferential fiber shortening (p=0.0142), the ejection fraction (p=0.0462), decrease in the end-systolic volume (p=0.0031) and no change in end-diastolic volume. CONCLUSION: Contrast ventriculography using nitrate proved to be similar to perfusional myocardial scintigraphy in the identification of myocardial ischemia.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the presence and the prevalence of arrhythmias and the variability of the heart rate in the medium-term postoperative period following the maze procedure for chronic atrial fibrillation (AF). METHODS: Seventeen patients with a mean age of 51.7±12.9 years, who previously underwent the maze procedure without cryoablation for chronic atrial fibrillation, were evaluated with the 24 hour electrocardiogram (ECG) - Holter monitoring from the 6th month after the operation. Valvular and coronary procedures were concomitantly performed. RESULTS: The mean heart rate during Holter monitoring was 82±8bpm; the maximal heart rate was 126 ± 23bpm and the minimal heart rate 57±7bpm. Sinus rhythm was found in 10 (59%) patients and atrial rhythm was found in 7 (41%). Supraventricular extrasystoles had a rate of 2.3±5.5% of the total number of heartbeats and occurred in 16 (94%) patients. Six (35%) patients showed nonsustained atrial tachycardia. Ventricular extrasystoles, with a rate of 0.8±0.5% of the total heartbeats, occurred in 14 (82%) patients. The chronotropic competence was normal in 9 (53%) patients and attenuated in 8 (47%). The atrioventricular conduction (AV) was unchanged in 13 (76%) patients and there were 4 (24%) cases of first degree atrioventricular block (AVB). CONCLUSION: After the maze procedure, the values for the mean heart rate, AV conduction and chronotropic competence approach the normal range, although some cases show attenuation of the chronotropic response, first degree AV block or benign arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate whether apolipoproteins A-I (Apo A-I) and B (Apo B) have, higher ensitivity (SN), specificity (SP) and positive predictive value (PPV) than lipoproteins (LP), total cholesterol (TC), high density lipoprotein (HDL), low density lipoprotein (LDL), very low density lipoprotein (VLDL), and triglycerides (TGL) in assessing the risk of coronary heart disease (CHD). METHODS: This is a transversal case-control study of 241 patients, who were divided into two groups: 1) 145 patients with CHD, and 2) 96 patients without coronary disease. A model of logistic regression to evaluate the relation between the LPs and CHD was developed in which variables with a p-alpha <0.1 were included. RESULTS: Apo A-I levels were higher in the patients without CHD, (OR 2.08, CI 1.20-3.57). There were no statistical differences between the values of Apo A-I and the remaining lipid fractions (Apo A-I: 67%; Apo B: 100%; PPV: TC= 71%; TGC=71%; HDL=71%; LDL=71%). The costs of the tests in Reais were as follows: Apo A-I: R$ 56.60; Apo B-100: R$ 56.60; TC: R$ 9.94; HDL: R$ 21.30; LDL: R$ 28.40; TGL: R$ 14.20. CONCLUSION: Levels of Apo A-I and Apo B have no advantage over conventional lipoproteins in predicting the risk of CHD, despite the statistical association between Apo A-I and CHD; in addition, their costs are higher than those of the conventional lipoproteins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors consider the possibility of using color Doppler of the ductus venosus and the measurement of nuchal translucency as a screening test for alterations in fetal cardiac functions in the first trimester of gestation. Review of the literature suggests that the combination of the ultrasonographic measurement of nuchal translucency and Doppler at 10 and 14 weeks of gestation can be effective in detecting certain cardiac abnormalities. This conclusion, however, is preliminary and needs to be further investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare peak exercise oxygen consumption (VO2peak) of healthy individuals with asymptomatic individuals with probable heart disease. METHODS: Ninety-eight men were evaluated. They were divided into two groups: 1) 39 healthy individuals (group N) with an age range of 50±4.6 years; and 2) 59 asymptomatic individuals with signs of atherosclerotic and/or hypertensive heart disease (group C) with an age range of 51.9±10.4 years. In regard to age, height, body surface area, percentage of fat, lean body mass, and daily physical activity, both groups were statistically similar. Environmental conditions during the ergometric test were also controlled. RESULTS: Maximal aerobic power (watts), VO2peak, maximal heart rate, and maximal pulmonary ventilation were lower in group C (p<0.01) than in group N; weight, however, was lower in group N (p=0.031) than in group C. Differences in the respiratory gas exchange index, heart rate at rest, and the maximal double product of the two groups were not statistically significant. CONCLUSION: Signs of probable heart disease, even though asymptomatic, may reduce the functional capacity, perhaps due to the lower maximal cardiac output and/or muscle metabolic changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - Studies have shown that therapy with beta-blockers reduces mortality in patients with heart failure. However, there are no studies describing the effects of propranolol on the QT dispersion in this population. The objective of this study was to assess the electrophysiological profile, mainly QT dispersion, of patients with heart failure regularly using propranolol. METHODS - Fifteen patients with heart failure and using propranolol were assessed over a period of 12 months. Twelve-lead electrocardiograms (ECG) were recorded prior to the onset of beta-blocker therapy and after 3 months of drug use. RESULTS - A significant reduction in heart rate, in QT dispersion and in QTc dispersion was observed, as was also an increase in the PR interval and in the QT interval, after the use of propranolol in an average dosage of 100 mg/day. CONCLUSION - Reduction in QT dispersion in patients with heart failure using propranolol may explain the reduction in the risk of sudden cardiac death with beta-blocker therapy, in this specific group of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - To identify, the anaerobic threshold and respiratory compensation point in patients with heart failure. METHODS - The study comprised 42 Men,divided according to the functional class (FC) as follows: group I (GI) - 15 patients in FC I; group II (GII) - 15 patients in FC II; and group III (GIII) - 12 patients in FC III. Patients underwent a treadmill cardiopulmonary exercise test, where the expired gases were analyzed. RESULTS - The values for the heart rate (in bpm) at the anaerobic threshold were the following: GI, 122±27; GII, 117±17; GIII, 114±22. At the respiratory compensation point, the heart rates (in bpm) were as follows: GI, 145±33; GII, 133±14; GIII 123±22. The values for the heart rates at the respiratory compensation point in GI and GIII showed statistical difference. The values of oxygen consumption (VO2) at the anaerobic threshold were the following (in ml/kg/min): GI, 13.6±3.25; GII, 10.77±1.89; GIII, 8.7±1.44 and, at the respiratory compensation point, they were as follows: GI, 19.1±2.2; GII, 14.22±2.63; GIII, 10.27±1.85. CONCLUSION - Patients with stable functional class I, II, and III heart failure reached the anaerobic threshold and the respiratory compensation point at different levels of oxygen consumption and heart rate. The role played by these thresholds in physical activity for this group of patients needs to be better clarified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been reported that growth hormone may benefit selected patients with congestive heart failure. A 63-year-old man with refractory congestive heart failure waiting for heart transplantation, depending on intravenous drugs (dobutamine) and presenting with progressive worsening of the clinical status and cachexia, despite standard treatment, received growth hormone replacement (8 units per day) for optimization of congestive heart failure management. Increase in both serum growth hormone levels (from 0.3 to 0.8 mg/l) and serum IGF-1 levels (from 130 to 300ng/ml) was noted, in association with clinical status improvement, better optimization of heart failure treatment and discontinuation of dobutamine infusion. Left ventricular ejection fraction (by MUGA) increased from 13 % to 18 % and to 28 % later, in association with reduction of pulmonary pressures and increase in exercise capacity (rise in peak VO2 to 13.4 and to 16.2ml/kg/min later). The patient was "de-listed" for heart transplantation. Growth hormone may benefit selected patients with refractory heart failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To describe a new more efficient method of endocardial cardiac stimulation, which produces a narrower QRS without using the coronary sinus or cardiac veins. METHODS: We studied 5 patients with severe dilated cardiomyopathy, chronic atrial fibrillation and AV block, who underwent definitive endocardial pacemaker implantation, with 2 leads, in the RV, one in the apex and the other in the interventricular septum (sub pulmonary), connected, respectively, to ventricular and atrial bicameral pacemaker outputs. Using Doppler echocardiography, we compared, in the same patient, conventional (VVI), high septal ("AAI") and bifocal ("DDT" with AV interval ~ 0) stimulation. RESULTS: The RV bifocal stimulation had the best results with an increase in ejection fraction and cardiac output and reduction in QRS duration, mitral regurgitation and in the left atrium area (p <= 0.01). The conventional method of stimulation showed the worst result. CONCLUSION: These results suggest that, when left ventricular stimulation is not possible, right ventricular bifocal stimulation should be used in patients with severe cardiomyopathy where a pacemaker is indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE:To determine the indication for and incidence and evolution of temporary and permanent pacemaker implantation in cardiac transplant recipients. METHODS: A retrospective review of 114 patients who underwent orthotopic heart transplantation InCor (Heart Institute USP BR) between March 1985 and May 1993. We studied the incidence of and indication for temporary pacing, the relationship between pacing and rejection, the need for pemanent pacing and the clinical follow-up. RESULTS: Fourteen of 114 (12%)heart transplant recipients required temporary pacing and 4 of 114 (3.5%) patients required permanent pacing. The indication for temporary pacing was sinus node dysfunction in 11 patients (78.5%) and atrioventricular (AV) block in 3 patients (21.4%). The indication for permanent pacemaker implantation was sinus node dysfunction in 3 patients (75%) and atrioventricular (AV) block in 1 patient (25%). We observed rejection in 3 patients (21.4%) who required temporary pacing and in 2 patients (50%) who required permanent pacing. The previous use of amiodarone was observed in 10 patients (71.4%) with temporary pacing. Seven of the 14 patients (50%) died during follow-up. CONCLUSION: Sinus node dysfunction was the principal indication for temporary and permanent pacemaker implantation in cardiac transplant recipients. The need for pacing was related to worse prognosis after cardiac transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE:To evaluate the use of methotrexate for the treatment of recurrent rejection in heart transplant recipients. METHODS: We studied 6 patients submitted to heart transplantation that showed rejection grade > or = 3A (ISHLT) in two consecutives endomyocardial biopsy specimens. The dose was 11.26±3.75mg/week. The evaluated data were: ventricular function, endomyocardial biopsy, white cell count and number of rejection episodes before and after methotrexate administration. RESULTS: There was a reduction in the number of rejection episodes (5.17±1.47 before methotrexate; 2.33±1.75 after 6 months and 3.17±2.99 after 12 months of treatment, p=0.0193). The ventricular function was normal with ejection fraction of 76.5±4.80 before and 75.6±4.59 after methotrexate (p=0.4859). One patient did not finish the treatment because he showed signs of rejection associated with severe pericardial effusion. Five patients had a reduction in the white cell count (8,108±23.72 before and 5650±1350 after methotrexate, p=0.0961). One pulmonary infection with complete resolution after antibiotic treatment was observed. CONCLUSION: Methotrexate in low doses is an effective adjunct therapy in the treatment of recurrent rejection after heart transplantation.