33 resultados para Angles subtraction
Resumo:
The objective of the present study was to determine the frequency of the most common clinical features in patients with autosomal dominant polycystic kidney disease in a sample of the Brazilian population. The medical records of 92 patients with autosomal dominant polycystic kidney disease attended during the period from 1985 to 2003 were reviewed. The following data were recorded: age at diagnosis, gender, associated clinical manifestations, occurrence of stroke, age at loss of renal function (beginning of dialysis), and presence of a family history. The involvement of abdominal viscera was investigated by ultrasonography. Intracranial alterations were prospectively investigated by magnetic resonance angiography in 42 asymptomatic patients, and complemented with digital subtraction arteriography when indicated. Mean age at diagnosis was 35.1 ± 14.9 years, and mean serum creatinine at referral was 2.4 ± 2.8 mg/dL. The most frequent clinical manifestations during the disease were arterial hypertension (63.3%), lumbar pain (55.4%), an abdominal mass (47.8%), and urinary infection (35.8%). Loss of renal function occurred in 27 patients (mean age: 45.4 ± 9.5 years). The liver was the second organ most frequently affected (39.1%). Stroke occurred in 7.6% of the patients. Asymptomatic intracranial aneurysm was detected in 3 patients and arachnoid cysts in 3 other patients. In conclusion, the most common clinical features were lumbar pain, arterial hypertension, abdominal mass, and urinary infection, and the most serious complications were chronic renal failure and stroke. Both intracranial aneurysms and arachnoid cysts occurred in asymptomatic patients at a frequency of 7.14%.
Resumo:
The aim of this study was to analyze the alterations of arm and leg movements of patients during stroke gait. Joint angles of upper and lower limbs and spatiotemporal variables were evaluated in two groups: hemiparetic group (HG, 14 hemiparetic men, 53 ± 10 years) and control group (CG, 7 able-bodied men, 50 ± 4 years). The statistical analysis was based on the following comparisons (P ≤ 0.05): 1) right versus left sides of CG; 2) affected (AF) versus unaffected (UF) sides of HG; 3) CG versus both the affected and unaffected sides of HG, and 4) an intracycle comparison of the kinematic continuous angular variables between HG and CG. This study showed that the affected upper limb motion in stroke gait was characterized by a decreased range of motion of the glenohumeral (HG: 6.3 ± 4.5, CG: 20.1 ± 8.2) and elbow joints (AF: 8.4 ± 4.4, UF: 15.6 ± 7.6) on the sagittal plane and elbow joint flexion throughout the cycle (AF: 68.2 ± 0.4, CG: 46.8 ± 2.7). The glenohumeral joint presented a higher abduction angle (AF: 14.2 ± 1.6, CG: 11.5 ± 4.0) and a lower external rotation throughout the cycle (AF: 4.6 ± 1.2, CG: 22.0 ± 3.0). The lower limbs showed typical alterations of the stroke gait patterns. Thus, the changes in upper and lower limb motion of stroke gait were identified. The description of upper limb motion in stroke gait is new and complements gait analysis.
Resumo:
The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.