84 resultados para Angioplasty, Balloon


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Clinical in-stent restenosis (CISR) is the main limitation of coronary angioplasty with stent implantation. Objective: Describe the clinical and angiographic characteristics of CISR and the outcomes over a minimum follow-up of 12 months after its diagnosis and treatment. Methods: We analyzed in 110 consecutive patients with CISR the clinical presentation, angiographic characteristics, treatment and combined primary outcomes (cardiovascular death, nonfatal acute myocardial infarction [AMI]) and combined secondary (unstable angina with hospitalization, target vessel revascularization and target lesion revascularization) during a minimal follow-up of one year. Results: Mean age was 61 ± 11 years (68.2% males). Clinical presentations included acute coronary syndrome (ACS) in 62.7% and proliferative ISR in 34.5%. CISR was treated with implantation of drug-eluting stents (DES) in 36.4%, Bare Metal Stent (BMS) in 23.6%, myocardial revascularization surgery in 18.2%, balloon angioplasty in 15.5% and clinical treatment in 6.4%. During a median follow-up of 19.7 months, the primary outcome occurred in 18 patients, including 6 (5.5%) deaths and 13 (11.8%) AMI events. Twenty-four patients presented a secondary outcome. Predictors of the primary outcome were CISR with DES (HR = 4.36 [1.44–12.85]; p = 0.009) and clinical treatment for CISR (HR = 10.66 [2.53–44.87]; p = 0.001). Treatment of CISR with BMS (HR = 4.08 [1.75–9.48]; p = 0.001) and clinical therapy (HR = 6.29 [1.35–29.38]; p = 0.019) emerged as predictors of a secondary outcome. Conclusion: Patients with CISR present in most cases with ACS and with a high frequency of adverse events during a medium-term follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: The kinetics of high-sensitivity troponin T (hscTnT) release should be studied in different situations, including functional tests with transient ischemic abnormalities. Objective: To evaluate the release of hscTnT by serial measurements after exercise testing (ET), and to correlate hscTnT elevations with abnormalities suggestive of ischemia. Methods: Patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary angioplasty were referred for ET 3 months after infarction. Blood samples were collected to measure basal hscTnT immediately before (TnT0h), 2 (TnT2h), 5 (TnT5h), and 8 hours (TnT8h) after ET. The outcomes were peak hscTnT, TnT5h/TnT0h ratio, and the area under the blood concentration-time curve (AUC) for hscTnT levels. Log-transformation was performed on hscTnT values, and comparisons were assessed with the geometric mean ratio, along with their 95% confidence intervals. Statistical significance was assessed by analysis of covariance with no adjustment, and then, adjusted for TnT0h, age and sex, followed by additional variables (metabolic equivalents, maximum heart rate achieved, anterior wall STEMI, and creatinine clearance). Results: This study included 95 patients. The highest geometric means were observed at 5 hours (TnT5h). After adjustments, peak hscTnT, TnT5h/TnT0h and AUC were 59% (p = 0.002), 59% (p = 0.003) and 45% (p = 0.003) higher, respectively, in patients with an abnormal ET as compared to those with normal tests. Conclusion: Higher elevations of hscTnT may occur after an abnormal ET as compared to a normal ET in patients with STEMI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR) 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vascular complications after liver transplantation include oclusion or stenosis at the sites of anastomosis in the hepatic artery, portal vein, and vena cava. Balloon angioplasty of these stenosis carries little risk and is a useful procedure for the treatment of these problems. The purpose of this paper was to assess whether percutaneous transluminal angioplasty can help to prolong allograft survival and impruve allograft function in patient with hepatic artery stenosis after liver transplantation. We report a 43-year-old mate with stenosis of hepatic artery anastomosis after liver transplantation. An abrupt elevation of liver enzymes and serum bilirrubin levels was noted on the fifth postoperative month. The patient underwent percutaneous liver biopsy, which revealed important ductal depletion due to hypoperfusion, even though Doppler ultrasound examination demonstrated arterial flow. An angiogram confirmed severe stenosis of the arterial anastomosis with poor intraparenchymal arterial perfusion pattern. In an attempt to preserve the graft, a percutaneous transluminal angioplasty was performed using microballoons mounted on a hydrophylic micro guidewire. Intervention proceeded without complications. Liver enzimes and bilirrubin levels decreased within twenty-four hours of angioplasty. Normal levels were achieved after one week. Seven month after angioplasty, the patient is in a optimal clinical condition with no signs of graft impairment. We conclude that percutaneous transluminal angioplasty of hepatic artery stenosis after liver transplantation is relatively safe and may help decrease allograft loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: to assess post-angioplasty myointimal hyperplasia in iliac artery of rabbits treated with extract of Moringa oleifera leaves. Methods : we conducted a randomized trial in laboratory animals for five weeks of follow-up, developed in the Vivarium of Pharmaceutical Technology Laboratory of the Universidade Federal da Paraíba. We used rabbits from the New Zealand breed, subjected to a hypercholesterolemic diet and angioplasty of the external iliac artery, randomized into two groups: M200 Group (n=10) - rabbits treated with 200mg/kg/day of Moringa oleifera leaves extract orally; SF group (n=10) - rabbits treated with 0.9% saline orally. After five weeks, the animals were euthanized and the iliac arteries prepared for histology. Histological sections were analyzed by digital morphometry. Statistical analysis was performed using the Student's t test. The significance level was 0.05. Results : there was no significant difference in myointimal hyperplasia between M200 and SF groups when comparing the iliac arteries submitted to angioplasty. Conclusion : there was no difference of myointimal hyperplasia between groups treated with saline and Moringa oleifera after angioplasty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute thrombosis can be induced in rabbits by a triggering protocol using Russell's viper venom and histamine given after 8 months of a 1% cholesterol diet and balloon desendothelization. In the present study, we tested the hypothesis that aortic desendothelization performed 4 months before the triggering protocol without a high cholesterol diet is a highly effective and less expensive way of producing arterial atherosclerosis and thrombosis. Nineteen male New Zealand white rabbits on a normal diet were studied. The control group (N = 9) received no intervention during the 4-month observation period, while the other group (N = 10) was submitted to aortic balloon desendothelization using a 4F Fogarty catheter. At the end of this period, all animals were killed 48 h after receiving the first dose of the triggering treatment. Eight of 10 rabbits (80%) in the balloon-trauma group presented platelet-rich arterial thrombosis while none of the animals in the control group had thrombus formation (P<0.01). Thus, this model, using balloon desendothelization without dietary manipulation, induces arterial atherosclerosis and thrombosis and may provide possibilities to test new therapeutic approaches

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complete spectrum of estrogen vascular effects remains unclear. In particular, estrogen effects in the vascular response to profound injury in males have not been explored in detail. Therefore, we submitted 44 male New Zealand rabbits weighing 3.4 ± 0.6 kg to overdistention balloon injury of the right iliac artery. Rabbits were given 17ß-estradiol (5.45 µmol/day, sc) or vehicle for 7 days before and 14 days after injury, when the arteries were examined by post-mortem histomorphometry. Arteriographic caliber was assessed in vivo at baseline and before sacrifice. On day 14 after injury, in vivo arteriographic caliber (baseline = 2.44 ± 0.43 mm) was decreased by 23.1 ± 0.1% in controls and by 44.5 ± 0.1% in estrogen-treated rabbits (P < 0.001). Neither the neointimal area nor the neointima/media area ratio changed after estrogen treatment. Collagen fraction was increased in the media and neointima of estrogen-treated rabbits vs control (1.38 ± 1.30 vs 0.35 ± 0.67, respectively, P = 0.01). Taken together, these findings suggest that estrogen increased negative vascular remodeling. Transcription of endothelial and inducible nitric oxide synthases (eNOS and iNOS) was analyzed by RT-PCR. eNOS mRNA expression was marginally increased after estrogen (P = 0.07) and injury. iNOS mRNA was increased 2- to 3-fold on day 14 after injury. With estrogen treatment, iNOS mRNA increased in uninjured arteries and exhibited a further 5.5-fold increase after injury. We concluded that estrogen increased lumen loss after balloon injury in male rabbits, likely by increased negative remodeling, which may be related to increased iNOS transcriptional rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Controversy exists regarding the diagnostic accuracy, optimal technique, and timing of exercise testing after percutaneous coronary intervention. The objectives of the present study were to analyze variables and the power of exercise testing to predict restenosis or a new lesion, 6 months after the procedure. Eight-four coronary multi-artery diseased patients with preserved ventricular function were studied (66 males, mean age of all patients: 59 ± 10 years). All underwent coronary angiography and exercise testing with the Bruce protocol, before and 6 months after percutaneous coronary intervention. The following parameters were measured: heart rate, blood pressure, rate-pressure product (heart rate x systolic blood pressure), presence of angina, maximal ST-segment depression, and exercise duration. On average, 2.33 lesions/patient were treated and restenosis or progression of disease occurred in 46 (55%) patients. Significant increases in systolic blood pressure (P = 0.022), rate-pressure product (P = 0.045) and exercise duration (P = 0.003) were detected after the procedure. Twenty-seven (32%) patients presented angina during the exercise test before the procedure and 16 (19%) after the procedure. The exercise test for the detection of restenosis or new lesion presented 61% sensitivity, 63% specificity, 62% accuracy, and 67 and 57% positive and negative predictive values, respectively. In patients without restenosis, the exercise duration after percutaneous coronary intervention was significantly longer (460 ± 154 vs 381 ± 145 s, P = 0.008). Only the exercise duration permitted us to identify patients with and without restenosis or a new lesion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Treatment of arterial traumatic intimal lesions is controversial due to its unknown natural history. Current therapeutical options include arterial reconstruction and clinical observation. The idea of using stents to correct intimal flaps is based on their use to correct dissections, flaps, and arterial irregularities after angioplasty. We report the successful treatment of a traumatic intimal flap of the superficial femoral artery, caused by gunshot trauma, with a Palmaz stent in the acute period. One year after the operation, a duplex scan revealed normal flow in the artery and complete exclusion of the intimal flap; distal pulses were palpable, and the patient was completely asymptomatic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives Unipolar depression (UPD) is a leading cause of global burden of diseases, particularly among the elderly, whose treatment may be challenging. In such cases, ECT is often recommended due to its safety and efficacy. This report presents a case of a 67-year-old male inpatient that developed a rare cardiac complication during ECT. Methods Clinical case report with patient’s consent and bibliographic review. Results A 67-year-old male inpatient with recurrent severe psychotic depression was hospitalized and ECT was indicated after failure of the pharmacological treatment. A comprehensive clinical pre-evaluation revealed only nonspecific ST-segment changes in electrocardiogram. During the 7th ECT session, it was observed transitory ST-segment depression followed by a discrete increase of plasma troponin I. Severe tri-vessel coronary artery stenosis was found and a percutaneous coronary angioplasty was performed, with satisfactory psychiatric and cardiac outcomes. Conclusions Unipolar depression (UPD) and cardiovascular disease are often coexistent conditions, especially among the elderly. In the current case, myocardial ischemia was detected lately during ECT therapy and its treatment allowed the UPD treatment to be completed adequately.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Analisar a perda do diâmetro luminal mínimo (DLM) nos primeiros 15min após angioplastia coronária por balão (AC), quantificando sua influência na reestenose coronária. MÉTODOS: Foram estudadas, prospectivamente, 86 AC em 86 pacientes. Os pacientes foram divididos em dois subgrupos de acordo com a presença ou ausência de reestenose; o 1º grupo compreendendo as 31 lesões com reestenose e o 2º, as 55 lesões sem reestenose. RESULTADOS: A análise univariada mostrou que a relação balão/artéria foi menor no grupo com reestenose (0,92±0,01 vs 1,00±0,11, P= .003). O grupo com reestenose apresentou maior recolhimento elástico absoluto e relativo no 1°min (0,79±0,54 vs 0,68±0,59mm; P= 0,007 e 32,04±14,27 vs 22,15±16,65%; P= 0,006.) e no controle angiográfico do 15°min (1,25±0,59 vs 0,90±0,65mm, P= 0,017 e 46,75±15,69 vs 29,18±17,84%, P<0,00001) do que o grupo sem reestenose. O DLM no 1°min foi menor no grupo com reestenose (2,15±0,42 vs 2,43±0,58mm; P=0,022). O grupo com reestenose apresentou uma maior perda precoce no DLM (0,46±0,34 vs 0,22±0,35mm, P= 0,004). Este decréscimo na luz do vaso determinou que o DLM do 15°min fosse ainda menor no grupo com reestenose (1,69±0,48 vs 2,20±0,61; P= 0,0001). Da análise multivariada, entretanto, identificou-se apenas a relação balão/artéria e o DLM do 15°min como os dois fatores independentes mais relacionados à reestenose. CONCLUSÃO: O recolhimento elástico e a perda do DLM ao longo dos 15min são fatores diretamente relacionados à reestenose. Entretanto, a análise multivariada mostrou que a relação balão/artéria e o DLM de 15min são os dois fatores independentes mais fortemente preditores de reestenose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the initial clinical experience of transmyocardial laser revascularization (TMLR) in patients with severe diffuse coronary artery disease. METHODS: Between February, 1998 and February, 1999, 20 patients were submitted to TMLR at the Heart Institute (InCor), University of São Paulo Medical School, Brazil, isolated or in association with conventional coronary artery bypass graft (CABG). All patients had severe diffuse coronary artery disease, with angina functional class III/IV (Canadian Cardiovascular Society score) unresponsive to medical therapy. Fourteen patients were submitted to TMLR as the sole therapy, whereas 6 underwent concomitant CABG. Fifty per cent of the patients had either been previously submitted to a CABG or to a percutaneous transluminal coronary angioplasty (PTCA). Mean age was 60 years, ranging from 45 to 74 years. RESULTS: All patients had three-vessel disease, with normal or mildly impaired left ventricular global function. Follow-up ranged from 1 to 13 months (mean 6.6 months), with no postoperative short or long term mortality. There was significant symptom improvement after the procedure, with 85% of the patients free of angina, and the remaining 15 % of the patients showing improvement in functional class, as well as in exercise tolerance. CONCLUSION: This novel technique can be considered a low risk alternative for a highly selected group of patients not suitable for conventional revascularization procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The authors analyzed the 30-day and 6-month outcomes of 1,126 consecutive patients who underwent coronary stent implantation in 1996 and 1997. METHODS: The 30-day results and 6-month angiographic follow-up were analyzed in patients treated with coronary stents in 1996 and 1997. All patients underwent coronary stenting with high-pressure implantation (>12 atm) and antiplatelet drug regimen (aspirin plus ticlopidine). RESULTS: During the study period, 1,390 coronary stents were implanted in 1,200 vessels of 1,126 patients; 477 patients were treated in the year 1996 and 649 in 1997. The number of percutaneous procedures performed using stents increased significantly in 1997 compared to 1996 (64 % vs 48%, p=0.0001). The 30-day results were similar in both years; the success and stent thrombosis rates were equal (97% and 0.8%, respectively). The occurrence of new Q wave MI (1.3% vs 1.1%, 1996 vs 1997, p=NS), emergency coronary bypass surgery (1% vs 0.6%, 1996 vs 1997, p=NS) and 30-day death rates (0.2% vs 0.5%, 1996 vs 1997, p=NS) were similar. The 6-month restenosis rate was 25% in 1996 and 27% in 1997 (p= NS); the target vessel revascularization rate was 15% in 1996 and 16% in 1997 (p = NS). CONCLUSIONS: Intracoronary stenting showed a high success rate and a low incidence of 30-day occurrence of new major coronary events in both periods, despite the greater angiographic complexity of the patients treated with in 1997. These adverse variables did not have a negative influence at the 6-month clinical and angiographic follow-up, with similar rates of restenosis and ischemia-driven target lesion revascularization rates.