801 resultados para operações de determinação e indeterminação


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper supplies a revision about the main techniques of extraction, clean-up and pre-concentration of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) in water and soil samples, as well as chromatographic methods and immune assays for its identification and quantification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sequential extraction is not totally effective to dissolve distinct forms of trace elements. The extractive solution, for example, can dissolve less of the target fraction and more than another not wished fraction. The goal of this work is to compare the extraction of native iron with three sequential extraction methods of the heavy metals, using three soils with different physical chemistry characteristics: a histosol, an oxisol, and a mollisol. The results obtained in this work demonstrate that a smaller relation soil/extractor results in a larger extraction in almost all phases. The use of many stages of the sequential extraction, with the purpose of more association of the metal with different components of the soil, can result, among other things, in modification of the substratum by the action of the reagents used, besides reducing the selectivity of the more specific extractors. Readsorption and redistribution of the heavy metals could have happened with larger intensity in the fraction where hidroxilamine was used with higher temperature. Sequential extraction of iron, without enrichment of soil samples, in the respective fractions in each method, it was important to better understand the behavior of the reagents considered specific to each form of the metal in soil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A brief discussion about the hydrogen peroxide importance and its determination is presented. It was emphasized some consideration of the H2O2 as reagent (separated or combined), uses and methods of analysis (techniques, detection limits, linear response intervals, sensor specifications). Moreover, it was presented several applications, such as in environmental, pharmaceutical, medicine and food samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work describes a new procedure for cetylpyridinium chloride determination in oral disinfectants, based on a flow-injection system with potentiometric detection. The determination was based on the measurement of picrate concentration decrease as result of ion-pair reaction with the analyte present in the injected sample. In the optimised set-up the sample injection volume was kept at 400 µL and merged downstream with the reagent solution containing 1,0 x10-5 mol/L of picrate adjusted to pH 5.0 with citrate/citric acid buffer. The flow rate was fixed at 8 mL/min and the reactor length at 40 cm. The proposed procedure enables the determination of cetylpyridinium in the analytical range of 5,0x10-6 - 7,5x10-5 mol/L at a sampling rate of 60/h. The results for real samples had a precision better than 3% and were comparable to the labelled values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acidic hydrolysis of samples is frequent in urinary 2,5-hexanodione determination. This hydrolysis should be performed under proper conditions, in order to avoid interference, such as the presence of 2,5-dimethylfurane and 2-acetylfurane. The results of the present work, as well as data from the literature, show that the use of non-polar or slightly polar chromatographic columns of 30 m length is an essential condition for 2,5-HD determination in an acid hydrolysed urine sample. In the same way the pH should be kept between 0.3 and 0.5. The mean concentrations of 2,5-HD in samples submitted to hydrolysis (0.50 ± 0.28 mg/g of creatinine) was about 3 times higher than those found in the samples without acid hydrolysis (0.19 ± 0.3 mg/g of creatinine).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fractIons of dichloromethane extracts of leaves from andiroba (Carapa guianensis - Meliaceae), caapi (Banisteriopsis caapi - Malpighiaceae), cocoa (Theobroma cacao - Sterculiaceae), Brazil nut (Bertholletia excelsa - Lecytidaceae), cupuaçu (Theobroma grandiflorum - Sterculiaceae), marupá (Simaruba amara - Simaroubaceae) and rubber tree (Hevea brasiliensis - Euphorbiaceae), were analyzed by HT-HRGC and HT-HRGC-MS. Esters of homologous series of fatty acids and long chain alcohols, phytol, amyrines and tocopherols were characterized. The characterization of the compounds was based mainly in mass spectra data and in addition by usual spectrometric data (¹H and 13C NMR, IR).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The toxicity of the major As species present in the environment justifies the effort for quantifying the element in environmental organic samples, which can vary from animal and vegetal tissues to coal and industrial residues. This paper comments about the applicability of the O2 bomb digestion, as a general procedure for all environmental organic materials. A rapid and straightforward method is suggested, which consists in burning the sample in the bomb at high O2 pressure, dissolving the vapours in diluted HNO3 and determining As in the resulting solution by atomic absorption spectrometry with electrothermal atomization. The method was applied to certified materials and plant samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper was to determine the 10-HDA in pure royal jelly and products containing royal jelly, using HPLC methodology. 10-HDA is the natural indicator of the presence of royal jelly in products and also gives the authenticity of pure royal jelly. The chromatographic conditions used were: isocratic system, C18-H column, auto sampler, diode array UV-VIS detector (225 nm), mobile phase with methanol/water (45:55), pH= 2.5 and a-naphtol as internal standard. The results obtained using laboratory samples for pure royal jelly were 2.37%, varying from 0.15% for honey with 10% of royal jelly to 2.10% for honey with 90% of royal jelly respectivelly. For commercial products, the 10-HDA content varied from no detectable to 0.026%. The recovery test presented a minumum of 100.44% The detection limit was 45.92 ng/mL and the quantification limit was 76.53 ng/mL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To improve tannin assay in cashew apple, several parameters were examined, including (1) extraction solvents, (2) effects of water and boiling time on butanol acid reaction and (3) correlation between vanillin and butanol acid assay of tannin in cashew apples. The 50-70% acetone extracted the greatest amount of tannin from cashew apples. Concentrations of water in butanol reagents were adjusted and boiling time of butanol reaction was reduced at 15 min. Tannin of unripe cashew apples was purified on Sephadex LH-20, aiming to obtain tannin standard for butanol assay. The vanillin assay presented high correlation with the butanol acid assay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The anodic voltammetric behavior of 4-chlorophenol (4-CF) in aqueous solution has been studied on a Boron-doped diamond electrode using square wave voltammetry (SWV). After optimization of the experimental conditions, 4-CF was analyzed in pure and natural waters using a Britton-Robinson buffer with pH = 6.0 as the supporting electrolyte. Oxidation occurs at 0.80 V vs Ag/AgCl in a two-electron process controlled by adsorption of the species. The detection limits obtained were 6.4 µg L-1 in pure water and 21.5 µg L-1 for polluted water taken from a local creek, respectively. The combination of square wave voltammetry and diamond electrodes is an interesting and desirable alternative for analytical determinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic dyes were determined by high performance liquid chromatography in 76 samples of regular jelly and diet jelly powders, of several flavors produced by seven different manufacturers. Three sample of each product, from different batches, were analyzed. The same qualitative composition was observed for products of the same flavor from different manufacturers, but the quantitative composition varied markedly from one manufacturer to the other. There were no or few significant differences between batches from a given manufacturer, demonstrating good quality control in the use of these additives by the food industry. None of the samples exceeded the limit stipulated by Brazilian legislation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a micro-heater device to be used as an integral part of the flow analysis manifold is described. The usefulness of the device was demonstrated using it in the development of a multicommutated flow analysis procedure for the spectrophotometric determination of manganese in plant digest. The method was based on the manganese oxidation by periodate in phosphoric acid medium to form the permanganate anion. The reaction development is dependent on the temperature and it was observed that at 25 °C a time interval of ca. 15 min was necessary for the reaction to attain equilibrium. Setting the temperature to 70 ºC, this time interval could be decreased to ca. 30 s. This condition was easily attained employing the proposed micro-heater device coupled to the manifold. The procedure was applied to manganese determination in soybean digests and results compared with those obtained by inductively coupled argon plasma optical emission spectrometry (ICP-OES). No significant difference at 90% confidence level was observed. A linear response for sample concentrations ranging from 5.0 to 30.00 mg L-1 Mn2+; a relative standard deviation of 1.3% (n = 6) for a typical sample containing 6.3 mg L-1 Mn2+; a sampling rate of 22 determinations per hour; a low reagent consumption, of 12.0 mg NaIO4 per determination; and a detection limit of 1.2 mg L-1 were achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Procion Green HE-4BD is a reactive dye currently used in affinity purification, and commonly present as a contaminant in the final biological preparation. An assay method is described to determine trace amounts of the dye in the presence of human serum albumin(HSA) and leakage from agarose as affinity sorbent by cathodic stripping voltammetry. The proposed method is based on the reductive peak at -0.55V in B-R buffer pH 3 (E=0V and t= 240s), obtained when samples of HSA 2% (m/v) containing dye concentrations in sodium hydroxide pH 12 are submitted to a heating time of 330 min at 80 ºC. Linear calibration curves can be obtained for RG19 dye concentrations from 5x10-9 mol L-1 to 8 x10-8 mol L-1. The detection limit (3sigma) is 1x10-9 mol L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discussion based on surfactant cleaning action is commonly used in chemistry classrooms for the comprehension of theoretical concepts related to surface tension and micelle formation. The experimental quantification of surface tension of aqueous solutions of surfactants provides the practical instruments for this discussion. The present paper describes a simplification on the common apparatus employed for the drop-weight method, making the determination of surface tension accessible to any chemistry lab. The surface tension of various liquids and the critical micelle concentration, CMC, of three commercial surfactants were measured with this modified method, and proved to be consistent with literature values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

European Directive (98/83/CE), compulsory after 2008, states that bromate in drinking water must be controlled at levels below 10 mg L-1. Supporting implementation of the Directive, the European Comission has established project SMT4-CT96 2134, in collaboration with various european institutions, aiming at the identification of the interferents to the current analytical method (Ionic Chromatography with Conductimetric Detection - IC/CD), their removal and the automation of pre-treatment and injection steps, as well as the development of alternative methods. EPAL, responsible for the water supply to a great deal of Portuguese regions, has taken steps to meet these requirements. Although not part of such project, this work (the result of a project conducted under a protocol of collaboration between EPAL SA and FCUL - Faculty of Sciences, University of Lisbon), reports on studies of usefulness to laboratories planning to monitor bromate in ozone treated waters, in conditions different from those described in EPA 300.1. Simultaneous determination of bromide is justified by its role as bromate precursor.