626 resultados para PID tuning. PID auto-tuning. Evaluation of control loops. Relay method. PID controllers


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ocular toxoplasmosis can result in recurrent uveitis. Studies have shown that a correlation between active ocular toxoplasmosis and the presence of anti-Toxoplasma gondii secretory IgA (SIgA) in tears. This study compares anti-T. gondii SIgA levels in patients' tears during the acute and inactive phases of toxoplasmic uveitis. Twenty-nine positive tear specific SIgA for T. gondii patients with acute toxoplasmic uveitis were selected and were followed-up for at least two years, when the anti-T. gondii SIgA tears levels were determined. Specific SIgA for T. gondii was negative in 22 patients (75.86%) and positive in seven patients (24.13%) of whom six (85.7%) were followed over three years. Average SIgA levels during the acute phase are 1.54 and decrease significantly to 0.72 (p = 0.0001) during the inactive phase of disease. Because anti-T. gondii SIgA in the tear is negative in 75.86% of patients after the acute phase of infection, T. gondii SIgA levels may be used as a complementary diagnostic marker for active ocular toxoplasmosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Candida parapsilosis, currently divided into three distinct species, proliferates in glucose-rich solutions and has been associated with infections resulting from the use of medical devices made of plastic, an environment common in dialysis centres. The aims of this study were (i) to screen for Candida orthopsilosis and Candida metapsilosis (100 environmental isolates previously identified as C. parapsilosis), (ii) to test the ability of these isolates to form biofilm and (iii) to investigate the in vitro susceptibility of Candida spp biofilms to the antifungal agents, fluconazole (FLC) and amphotericin B (AMB). Isolates were obtained from a hydraulic circuit collected from a haemodialysis unit. Based on molecular criteria, 47 strains were re-identified as C. orthopsilosis and 53 as C. parapsilosis. Analyses using a formazan salt reduction assay and total viable count, together with microscopy studies, revealed that 72 strains were able to form biofilm that was structurally similar, but with minor differences in morphology. A microtitre-based colorimetric assay used to test the susceptibility of fungal biofilms to AMB and FLC demonstrated that the C. parapsilosis complex displayed an increased resistance to these antifungal agents. The results from these analyses may provide a basis for implementing quality controls and monitoring to ensure the microbiological purity of dialysis water, including the presence of yeast.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the authors review the literature and share their experience of the principal biological markers of fibrosis for the evaluation of periportal fibrosis (PPF) caused by mansoni schistosomiasis. These biological markers are compared to diagnostic ultrasound (US) scans as means of grading PPF. We also review procollagen type I and III, collagen type IV, laminin, hyaluronic acid (HA), immunoglobulin G, platelets, aspartate aminotransferase to platelet ratio index (APRI) and gamma-glutamyl transpeptidase as markers of the disease. Although there are several good markers for evaluating PPF and portal hypertension, such as HA, platelets or APRI, none can yet replace US. These markers may, however, be used to identify patients at greater risk of developing advanced disease in endemic areas and determine who will need further care and US studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to evaluate a dot-enzyme-linked immunosorbent assay (dot-ELISA) using excretory-secretory antigens from the larval stages of Toxocara canis for the diagnosis of toxocariasis. A secondary aim was to establish the optimal conditions for its use in an area with a high prevalence of human T. canis infection. The dot-ELISA test was standardised using different concentrations of the antigen fixed on nitrocellulose paper strips and increasing dilutions of the serum and conjugate. Both the dot-ELISA and standard ELISA methods were tested in parallel with the same batch of sera from controls and from individuals living in the problem area. The best results were obtained with 1.33 µg/mL of antigen, dilutions of 1/80 for the samples and controls and a dilution of 1/5,000 for the anti-human IgG-peroxidase conjugate. All steps of the procedure were performed at room temperature. The coincidence between ELISA and dot-ELISA was 85% and the kappa index was 0.72. The dot-ELISA test described here is rapid, easy to perform and does not require expensive equipment. Thus, this test is suitable for the serological diagnosis of human T. canis infection in field surveys and in the primary health care centres of endemic regions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The activity of five (1-5) abietane phenol derivatives against Leishmania infantum and Leishmania braziliensis was studied using promastigotes and axenic and intracellular amastigotes. Infectivity and cytotoxicity tests were performed with J774.2 macrophage cells using Glucantime as a reference drug. The mechanisms of action were analysed by performing metabolite excretion and transmission electron microscopy ultrastructural studies. Compounds 1-5 were more active and less toxic than Glucantime. The infection rates and mean number of parasites per cell observed in amastigote experiments showed that derivatives 2, 4 and 5 were the most effective against both L. infantum and L. braziliensis. The ultrastructural changes observed in the treated promastigote forms confirmed that the greatest cell damage was caused by the most active compound (4). Only compound 5 caused changes in the nature and amounts of catabolites excreted by the parasites, as measured by ¹H nuclear magnetic resonance spectroscopy. All of the assayed compounds were active against the two Leishmania species in vitro and were less toxic in mammalian cells than the reference drug.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although several studies have evaluated the role of p16INK4a as a diagnostic marker of cervical intraepithelial neoplasia (CIN) and its association with disease progression, studies regarding the role of p16INK4a in human immunodeficiency virus (HIV)-infected patients remain scarce. The present study was designed to determine the potential utility of p16INK4a as a diagnostic marker for CIN and invasive cervical cancer in HIV-positive and negative cervical specimens. An immunohistochemical analysis of p16INK4a was performed in 326 cervical tissue microarray specimens. Performance indicators were calculated and compared using receiving operating characteristics curve (ROC)/area under the curve. In HIV-1-negative women, the percentage of cells that was positive for p16INK4a expression was significantly correlated with the severity of CIN (p < 0.0001). A ROC curve with a cut-off value of 55.28% resulted in a sensitivity of 89%, a specificity of 81%, a positive predictive value of 91% and a negative predictive value of 78%. HIV-seropositive women exhibited decreased expression of p16INK4a in CIN2-3 specimens compared with HIV-negative specimens (p = 0.031). The ROC data underscore the potential utility of p16INK4a under defined conditions as a diagnostic marker for CIN 2-3 staging and invasive cervical cancer. HIV-1 infection, however, is associated with relatively reduced p16INK4a expression in CIN 2-3.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The microplate nitrate reductase assay (MNRA) and the rezasurin microtitre assay (REMA) were used for the susceptibility testing of 73 clinical isolates and the results were compared with those that were obtained using the Bactec 460 TB and Bactec MGIT 960 systems. The REMA and the MNRA were performed in 96-well plates. For the REMA, the concentrations of isoniazid (INH) and rifampicin (RIF) ranged from 1.0-0.01 µg/mL and 2.0-0.03 µg/mL, respectively. For the MNRA, the INH concentration was between 1.0-0.03 µg/mL and the RIF concentration was between 2.0-0.06 µg/mL. For the MNRA, the sensitivity, specificity, positive predictive value, negative predictive value and INH/RIF agreement were 100/95.6, 97.6/100, 96.8/100, 100/98 and 98.6/98.6, respectively, and for the REMA, they were 100/91.3, 90.4/100, 88.5/100, 100/96.1 and 94.5/97.2, respectively. Our data suggest that these two rapid, low-cost methods may be inexpensive, alternative assays for the rapid detection of multidrug resistant tuberculosis in low-income countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the occurrence of schistosomiasis in areas with low endemicity using polymerase chain reaction (PCR) as a diagnostic method. We analysed faecal samples from 219 individuals residing in Piau and Coronel Pacheco, state of Minas Gerais, Brazil, using a single faecal sample from each individual and two slides of the Kato-Katz technique as a gold standard. Fifteen out of the 219 samples were positive with both methods of diagnosis. One sample was diagnosed as positive by the Kato-Katz technique only and 61 were diagnosed only by PCR. The positivity rates were 7.3% with the Kato-Katz method and 34.7% with PCR. When both techniques were assumed to have 100% specificity and positive individuals were identified by both methods, the sensitivity of the Kato-Katz method was 20.8% and the PCR sensitivity was 98.7%. The Kappa index between the two techniques was 0.234, suggesting weak agreement. The assessment of a single faecal sample by PCR detected more cases of infection than the analysis of one sample with two slides using the Kato-Katz technique, suggesting that PCR can be a useful diagnostic tool, particularly in areas with low endemicity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, we evaluated several techniques for the detection of the yeast form of Cryptococcus in decaying wood and measured the viability of these fungi in environmental samples stored in the laboratory. Samples were collected from a tree known to be positive for Cryptococcus and were each inoculated on 10 Niger seed agar (NSA) plates. The conventional technique (CT) yielded a greater number of positive samples and indicated a higher fungal density [in colony forming units per gram of wood (CFU.g-1)] compared to the humid swab technique (ST). However, the difference in positive and false negative results between the CT-ST was not significant. The threshold of detection for the CT was 0.05.10³ CFU.g-1, while the threshold for the ST was greater than 0.1.10³ CFU-1. No colonies were recovered using the dry swab technique. We also determined the viability of Cryptococcus in wood samples stored for 45 days at 25ºC using the CT and ST and found that samples not only continued to yield a positive response, but also exhibited an increase in CFU.g-1, suggesting that Cryptococcus is able to grow in stored environmental samples. The ST.1, in which samples collected with swabs were immediately plated on NSA medium, was more efficient and less laborious than either the CT or ST and required approximately 10 min to perform; however, additional studies are needed to validate this technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to investigate sensitivity disorders in the oral cavity related to the presence of Mycobacterium leprae in the saliva of treatment-naïve patients with leprosy in the state of Amazonas, Brazil. A cross-sectional study was conducted involving 45 subjects with leprosy. The subjects were interviewed to evaluate the sensitivity of the oral cavity. For the detection of M. leprae, saliva and slit-skin smear samples were collected. The samples were analysed using a bacteriological index (BI) protocol and the real-time quantitative polymerase chain reaction (qPCR). The results indicated that 15 of the 45 (33.3%) subjects with leprosy showed decreased oral sensitivity, which confirmed the importance of the oral cavity sensitivity evaluation. There was not a direct relationship between the presence of M. leprae in saliva and changes in oral sensitivity. Positive saliva qPCR results from six (31.6%) of 19 paucibacillary (PB) patients suggested the possibility of a new site for sample collection. Positive results using these diagnostic techniques (BI, slit-skin smear and saliva qPCR) increased to 55.5%, thus opening the possibility of combining these different techniques to increase the rate of positive diagnoses, especially in PB patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The etiological treatment of Chagas disease is recommended for all patients with acute or recent chronic infection, but controversies remain regarding the benefit of chemotherapy and interpretations of the parasitological cure after etiological treatment. This study compares the laboratory and clinical evaluations of Chagas disease patients who were diagnosed 13 years earlier. Fifty-eight Chagas disease patients (29 treated with benznidazole and 29 untreated) were matched at the time of treatment based on several variables. Conventional serology revealed the absence of seroconversion in all patients. However, lower serological titres were verified in the treated group, primarily among patients who had the indeterminate form of the disease. Haemoculture performed 13 years after the intervention was positive for 6.9% and 27.6% of the treated and untreated patients, respectively. Polymerase chain reaction tests were positive for 44.8% and 13.8% of the treated and untreated patients, respectively. Patients who presented with the indeterminate form of the disease at the beginning of the study exhibited less clinical progression (17.4%) compared with the untreated group (56.5%). Therefore, this global analysis revealed that etiological treatment with benznidazole may benefit patients with respect to the clinical progression of Chagas disease and the prognosis, particularly when administered to patients with the indeterminate form of the disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The disappearance of lytic, protective antibodies (Abs) from the serum of patients with Chagas disease is accepted as a reliable indicator of parasitological cure. The efficiency of a chemiluminescent enzyme-linked immunosorbent assay based on a purified, trypomastigote-derived glycosylphosphatidylinositol-anchored mucin antigen for the serologic detection of lytic Abs against Trypanosoma cruzi was evaluated in a nonendemic setting using a panel of 92 positive and 58 negative human sera. The technique proved to be highly sensitive {100%; 95% confidence interval (CI) = 96-100} and specific (98.3%; 95% CI = 90.7-99.7), with a kappa score of 0.99. Therefore, this assay can be used to detect active T. cruzi infection and to monitor trypanosomicidal treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In 2009, the World Health Organization (WHO) issued a new guideline that stratifies dengue-affected patients into severe (SD) and non-severe dengue (NSD) (with or without warning signs). To evaluate the new recommendations, we completed a retrospective cross-sectional study of the dengue haemorrhagic fever (DHF) cases reported during an outbreak in 2011 in northeastern Brazil. We investigated 84 suspected DHF patients, including 45 (53.6%) males and 39 (46.4%) females. The ages of the patients ranged from five-83 years and the median age was 29. According to the DHF/dengue shock syndrome classification, 53 (63.1%) patients were classified as having dengue fever and 31 (36.9%) as having DHF. According to the 2009 WHO classification, 32 (38.1%) patients were grouped as having NSD [4 (4.8%) without warning signs and 28 (33.3%) with warning signs] and 52 (61.9%) as having SD. A better performance of the revised classification in the detection of severe clinical manifestations allows for an improved detection of patients with SD and may reduce deaths. The revised classification will not only facilitate effective screening and patient management, but will also enable the collection of standardised surveillance data for future epidemiological and clinical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study analysed the concordance among four different molecular diagnostic methods for tuberculosis (TB) in pulmonary and blood samples from immunocompromised patients. A total of 165 blood and 194 sputum samples were collected from 181 human immunodeficiency virus (HIV)-infected patients with upper respiratory complaints, regardless of suspicious for TB. The samples were submitted for smear microscopy, culture and molecular tests: a laboratory-developed conventional polymerase chain reaction (PCR) and real-time quantitative PCR (qPCR) and the Gen-Probe and Detect-TB Ampligenix kits. The samples were handled blindly by all the technicians involved, from sample processing to results analysis. For sputum, the sensitivity and specificity were 100% and 96.7% for qPCR, 81.8% and 94.5% for Gen-Probe and 100% and 66.3% for Detect-TB, respectively. qPCR presented the best concordance with sputum culture [kappa (k) = 0.864)], followed by Gen-Probe (k = 0.682). For blood samples, qPCR showed 100% sensitivity and 92.3% specificity, with a substantial correlation with sputum culture (k = 0.754) and with the qPCR results obtained from sputum of the corresponding patient (k = 0.630). Conventional PCR demonstrated the worst results for sputa and blood, with a sensitivity of 100% vs. 88.9% and a specificity of 46.3% vs. 32%, respectively. Commercial or laboratory-developed molecular assays can overcome the difficulties in the diagnosis of TB in paucibacillary patients using conventional methods available in most laboratories.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The role of ATP-binding cassette (ABC) transporters in the efflux of the insecticide, temephos, was assessed in the larvae of Aedes aegypti. Bioassays were conducted using mosquito populations that were either susceptible or resistant to temephos by exposure to insecticide alone or in combination with sublethal doses of the ABC transporter inhibitor, verapamil (30, 35 and 40 μM). The best result in the series was obtained with the addition of verapamil (40 μM), which led to a 2x increase in the toxicity of temephos, suggesting that ABC transporters may be partially involved in conferring resistance to the populations evaluated.