408 resultados para trace mineral requirements
Resumo:
In this work, using the EPR spectroscopy, we analysed the thermal stability of some organic-mineral compounds found in a Gleysoil from Rio Janeiro. It was observed a complete disappearance of the EPR signal around 600 °C for the < 2 µm fraction and a residual EPR signal of semiquinone free radical for the 2-20 µm and 20-53 µm fractions at the same temperature. Also, the experiments showed that the 2-20 µm fraction had a larger concentration of semiquinone free radical per g of carbon and a smaller line width indicated a larger humification of this fraction. This is an evidence that the soil organic matter of this fraction (2-20 µm) is more stable than the other ones.
Resumo:
Ultra-trace amounts of Cu(II) were separated and preconcentrated by solid phase extraction on octadecyl-bonded silica membrane disks modified with a new Schiff,s base (Bis- (2-Hydroxyacetophenone) -2,2-dimethyl-1,3-propanediimine) (SBTD) followed by elution and inductively coupled plasma atomic emission spectrometric detection. The method was applied as a separation and detection method for copper(II) in environmental and biological samples. Extraction efficiency and the influence of sample matrix, flow rate, pH, and type and minimum amount of stripping acid were investigated. The concentration factor and detection limit of the proposed method are 500 and 12.5 pg mL-1, respectively.
Resumo:
This work aims to study the oxidation of a complex molybdenite mineral which contains pyrite and pyrrotite, by Acidithiobacillus ferrooxidans. This study was performed by respirometric essays and bioleaching in shake flasks. Respirometric essays yielded the kinetics of mineral oxidation. The findings showed that sulfide oxidation followed classical Michaelis-Menten kinetics. Bioleaching in shake flasks allowed evaluation of chemical and mineralogical changes resulting from sulfide oxidation. The results demonstrated that pyrrotite and pyrite were completely oxidized in A. ferrooxidans cultures whereas molybdenite was not consumed. These data indicated that molybdenite was the most recalcitrant sulfide in the sample.
Resumo:
The main objective of this study was the identification of sources generating particulate matter in the atmospheric aerosols of Sete Lagoas, Minas Gerais. The measurement of the mineral composition was accomplished by X-ray diffractometry and the elemental concentration by neutron activation analysis. The results showed that Al, Cl, Cu, Fe, K, Mg and Na are the predominant chemical elements in the total suspended particles (TPS). The presence of Na, Ba, Cl, Cu, Eu, Fe and Sm in those particles with aerodynamic diameter smaller than 10 µm (PM10), indicates that soil dust and ceramic and pig iron industries are the main sources of air quality degradation in the region.
Resumo:
The purpose of this study was to assess the concentration of vitamins and minerals in meat protein hydrolysates. Calcium, phosphorus and iron were analyzed by inductively coupled-plasma atomic emission spectrophotometry; vitamin C was analyzed by the reduction of cupric ions and vitamins B1 and B2 by fluorescence. Regarding minerals, the beef hydrolysate (BH) had more iron than the turkey hydrolysate (TH) and the chicken hydrolysate (CH); TH had a little more phosphorus. BH had the largest amount of vitamin C, and similar amounts of vitamins B1 and B2. The amount of these nutrients found in the hydrolysates suggests that it is possible to use them to enrich special dietary formulations.
Resumo:
Knowledge of coal combustion kinetics is crucial for burner design. This work aims to contribute on this issue by determining the kinetics of a particular Brazilian bituminous coal. Non-isothermal thermogravimetry was applied for determining both the pre-exponential factor and the activation energy. Coal samples of 10 mg and 775 mm mean size were used in synthetic air atmospheres (21 % O2). Heating rates from 10 to 50 ºC/min were applied until the temperature reached 850 ºC, which was kept constant until burnout. The activation energy for the primary and the secondary combustion resulted, respectively, in 135.1 kJ/mol and 85.1 kJ/mol.
Resumo:
The selective ion monitoring acquisition mode in mass spectrometry was applied to identify, in the diesel complex matrix, the raw materials (vegetable oil and alcohol) that originate biodiesel. Biodiesel samples obtained from babassu, castor, palm and soybean vegetable oils and pure fatty acid methyl and ethyl esters were used to develop this method, using specific fragments in mass spectrometry and the "window system" in gas chromatography. The commercial Brazilian B2 samples were found to be produced with soybean oil, transesterified with methanol.
Resumo:
A characterization of activated bauxite and of activated bauxite impregnated with insulating mineral oil was made. The activated bauxite is used as adsorbent material in percolators during the regeneration of insulating mineral oil. After regeneration an insulating mineral oil is obtained with physical and chemical characteristics similar to those of the new oil. Moreover, saturated activated bauxite impregnated with insulating mineral oil is also produced. It is a dangerous residue according to NBR 10004 (Class I) and, thus, harmful to the environment. An alternative use of this waste in the ceramic industry is discussed.
Resumo:
The sorption of thiamethoxam in a Brazilian Oxisol was determined in soil samples with and without organic matter for two different dephs (0-0.1 and 0.4-0.7 m). The results indicated a predominant sorption of thiamethoxam on soil without organic matter. The following Kd values of 4.25 mL g-1 (0-0.1 m, r² = 0.8534) and 5.30 mL g-1 (0.4-0.7 m, r² = 0.9884) and Kf values, 7.65 mL g-1 (0-0.1 m, r² = 0.9623) and 7.72 mL g-1 (0.4-0.7 m, r² = 0.9775) were obtained. Those sorption coefficient values indicated a small interaction between thiamethoxam for both original soil and soil without organic matter.
Resumo:
An efficient flotation method based on the combination of flame atomic absorption spectrometry (FAAS) and separation and preconcentration step for determination of Cr3+, Cu 2+, Co2+, Ni2+, Zn2+, Cd 2+, Fe3+ and Pb2+ ions in various real samples by the possibility of applying bis(2-hydroxyacetophenone)-1,4-butanediimine (BHABDI) as a new collector was studied. The influence of pH, amount of BHABDI as collector, sample matrix, type and amount of eluting agent, type and amount of surfactant as floating agent, ionic strength and air flow rates i.e. variables affecting the efficiency of the extraction system was evaluated. It is ascertained that metal ions such as iron can be separated simultaneously from matrix in the presence of 0.012 mM ligand, 0.025% (w/v) of CTAB to a test sample of 750 mL at pH 6.5. These ions can be eluted quantitatively with 6 mL of 1.0 mol L-1 HNO3 in methanol which lead to the enrichment factor of 125. The detection limits for analyte ions were in the range of 1.3-2.4 ng mL-1. The method has been successfully applied for determination of trace amounts of ions in various real samples.
Resumo:
In this research, we seek to corroborate the contributions of Chemistry to the identification, extraction and classification of minerals in the XVIII century, as well as, to approach the discussion that History of Chemistry shouldn't be understood in terms of a tight line of thoughts. For that, we analyze the work of Johann Andreas Cramer (1710-1777), Elements of the Art of Assaying Metals. Cramer proposed a method of mineral assaying based on the chemical behavior of the bodies, which allowed him to identify, extract and classify the minerals with more assertiveness.
Resumo:
The application of organo nanoclay 5-(4-dimethylamino-benzylidene) rhodanine-immobilized as a new, easily prepared, and stable solid sorbent for preconcentration trace amounts of Au(III) ions in aqueous solution is presented. The sorption of Au(III) ions was quantitative in the pH range of 2-4, and quantitative desorption occurred instantaneously with 10.0 mL of a mixture containing 0.5 mol L-1 Na2S2O3 and KSCN. Various parameters, such as the effect of pH, breakthrough volume, extraction time, and interference of a large number of anions and cations have been studied. The proposed method has been applied for determination of trace amount of gold in water samples.
Resumo:
Levels of Ca, Mg, Fe, Zn, Cu and Mn were determinated by FAAS in the tea and dry matter from senescent leaf from Montrichardia linifera, plant used in folk medicine Amazon. The content of these metals that are transferred of the leaf to the infusions have presented significant reductions, however, the Mn values in the infusion may exceed the tolerable daily intake (11 mg) if consumption of this tea is greater than 1.0 L per day. So the tea of senescent leaves of M. linifera may be considered as a toxic beverage and thus its use is not advised.
Resumo:
A simple ion pair-dispersive liquid-liquid microextraction method was proposed for preconcentration trace amounts of rhodium. An ion association complex of RhCl4- and tetradecyldimetylbenzylamonium was extracted into cholorobenzene. The volume and the type of extractive and dispersive solvents, the extraction time and the pH of the aqueous solutions were optimized. The calibration curve was linear in the range of 0.6-500 ng mL-1 of rhodium. The limit of detection was 0.10 ng mL-1 in initial solution and preconcentration factor was 40. The proposed method was successfully applied to the extraction and determination of rhodium in road dust and water samples.
Resumo:
In the proposed method, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, such as extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, linearity was maintained between 1.0 ng mL-1 to 1.5 mg mL-1 for zinc and 1.0 ng mL-1 to 0.4 mg mL-1 for cadmium. The proposed method has been applied for determination of trace amount of zinc and cadmium in standard and water samples with satisfactory results.