586 resultados para Massas de água


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Little is known about the amount of water and ash in brazilian foodstuffs and plants. The relationships between fresh, dry and ash weight were determined in 40 different biological samples. It could be an important tool when one studies biological material containing low concentration of the chemical elements. This study address to determine these relationships and to provide the amount of biological material that one needs to collect. It aims to supply information that could be used to improve the detection limit, precision and accuracy of the analytical methodology utilized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selenium is both essential and toxic to man and animals, depending on the concentration and the ingested form. Most fruits and vegetables are poor sources of selenium, but coconut can be a good selenium source. Samples were suspended (1 + 4 v/v) in a mixture of tertiary amines soluble in water (10% v/v CFA-C). This simple sample treatment avoided contamination and decreased the analysis time. The standard additions method was adopted for quantification. The action of the autosampler was improved by the presence of the amines mixture in the suspension. A Varian model AA-800 atomic absorption spectrometer equipped with a graphite furnace and a GTA 100 autosampler was used for selenium determination in coconut water and coconut milk. Background correction was performed by means of the Zeeman effect. Pyrolytically coated graphite tubes were employed. Using Pd as chemical modifier, the pyrolysis and the atomization temperatures were set at 1400 and 2200ºC, respectively. For six samples, the selenium concentration in coconut water varied from 6.5 to 21.0 mug L-1 and in coconut milk from 24.2 to 25.1 mug L-1. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values are in the 99.5-102.3% range. The main advantage of the proposed method is that it can be directly applied without sample decomposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combination of cyclic voltammetry and on line mass spectrometry, called differential electrochemical mass spectrometry (DEMS), is already a well established method for on line identification and quantitative detection of the products and intermediates of electrochemical reactions. This article aims to show the principles of the method and how this technique have been used to study electrochemical problems such the electrocatalytic oxidation of organic molecules, as methanol and ethanol, at noble metal electrodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water Quality Index (WQI) was used during summer and winter of 1994 and 1995 in the final section of Onça and Feijão streams, downstream Broa Reservoir (São Carlos/SP) to evaluate agricultural and catlleman effects. In Onça stream water quality was "acceptable" in winter and "inappropriate to conventional treatment" in the summer. In Feijão stream the water had an "excellent" quality in winter and "good" in the summer. A MANOVA (Multivariate Analysis of Variance) has used to discriminate seasons and streams. Correlation (p<0,05) among the variables was tested. Water temperature, turbidity, pH and fecal bacteria are highly correlated and can be one of the factors that cause WQI change by seasons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pyrethroids bifenthrin, permethrin, cypermethrin and deltamethrin were extracted by solid phase extraction (SPE) and solid phase microextraction (SPME). The analysis were performed on a gas chromatograph with electron capture detection (GC-ECD). Octadecil Silano-C18, Florisil and Silica stationary phases were studied for SPE. Better results were obtained for Florisil which gave recoveries from 80% to 108%. Pyrethroids extraction by SPME showed a linear response and a detection limit of 10 pg ml-1. Although the data showed that the two extraction methods were able to isolate the pesticide residues from water samples, the best results were obtained by using SPME which is more sensitive, faster, cheeper, being a more useful technique for the analysis of pyrethroids in drinking water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of water samples containing volatile organic compounds has become an important task in analytical chemistry. Gas chromatography has been widely used for the analysis of volatile organic compounds in water. The headspace analysis shows as a principal characteristic the possibility of determination of the volatile components in drinking water. Benzene, Toluene and Xylene (BTX) are important compounds usually present in drinking water, from contamination by petroleum derivatives. Since they are toxic compounds even when present in low concentration levels, their determination is important in order to define the quality of the water. The sampling technique using headspace, coupled with gas chromatography as the separation method, showed to be suitable for BTX analysis in several samples at the mug/L (ppb) level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and inexpensive time-of-flight mass spectrometer, dedicated to the study of gas-phase ionization processes induced by high energy electrons (0.5 - 3.0 keV), is described. The spectrometer design is based on the Wiley-McLaren principle, with a total length of about 18 cm. As a demonstration of the performance of the apparatus, mass spectra for Ar, CH4, CO2, and SF6, obtained at 1 keV electron energy, are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simultaneous electrolytic deposition is proposed for minimization of Cu2+ and Pb2+ interferences on automated determination of Cd2+ by the Malachite Green-iodide reaction. During electrolysis of sample in a cell with two Pt electrodes and a medium adjusted to 5% (v/v) HNO3 + 0.1% (v/v) H2SO4 + 0.5 mol L-1 NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. With 60 s electrolysis time and 0.25 A current, Pb2+ and Cu2+ levels up to 50 and 250 mg L-1 respectively, can be tolerated without interference. With on-line extraction of Cd2+ in anionic resin minicolumn, calibration graph in the 5.00 - 50.0 µg Cd L-1 range is obtained, corresponding to twenty measurements per hour, 0.7 mg Malachite Green and 500 mg KI and 5 mL sample consumed per determination. Results of the determination of Cd in certified reference materials, vegetables and tap water were in agreement with certified values and with those obtained by GFAAS at 95% confidence level. The detection limit is 0.23 µg Cd L-1 and the RSD for typical samples containing 13.0 µg Cd L-1 was 3.85 % (n= 12).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Six supercritical fluid extraction (SFE) methods were tested, by varying the following operational parameters: CO2 pressure, time and temperature of extraction, type and proportion of static modifier, and Hydromatrix®/sample rate into cell. Firstly, insecticide carbamates were extracted from spiked potatoes samples (fortification level of 0,5 mg.Kg-1) by using SPE procedures, and then final extracts were analyzed HPLC/fluorescence. Good performance was observed with SFE methods that operated with values of temperature and CO2 pressure of 50 ºC and 350 bar, respectively. Best efficiency was obtained when it was used acetonitrile as a modifier (3% on the cell volume), and Hydromatrix®/sample rate of 2:1. Static time was of 1 min; total extraction time was of 35 min; dynamic extraction was performed with 15 mL of CO2, and it was used methanol (2 mL) for the dissolution of the final residue. In such conditions, pesticide recoveries varied from 72 to 94%, depending on the analyzed compound. In higher extraction temperatures, a rapid degradation was observed for some compounds, such as aldicarb and carbaryl; presence of their metabolites was further confirmed by HPLC-APCI/MS in positive mode. Detection limits for chromatographic analysis varied from 0,2 to 1,3 ng.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Values of repeatability (r) and reproducibility (R) are parameters of an analytical method. They are related to the maximum difference between two results of analysis (permissible range) and can be obtained by interlaboratorial comparisons. They represent great importance for the quality control of the results and decisions about the fitness-for-purpose of the method. Water determination in fuel oil samples were performed by 16 laboratories, using the Karl Fischer reaction, during the period from June 1997 to December 1999. Values of r and R were presented. Discussion is made in terms of the main factors that would be contribution to analytical method variabilities and uncertainties of final results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coal ashes produced in coal-fired power plant could be converted into zeolites and can be used as low-cost adsorbents for the treatment of effluents contaminated with high levels of toxic metals. The capacity of synthetic zeolites for the removal of cadmium, zinc and copper ions from aqueous solutions has been investigated under different operating conditions. Zeolite from bottom chimney showed higher removal efficiency for metals ions than zeolite from feed hopper and mixing mill. The results indicated that the treated bottom ash could be applied in environmental technology as an immobilizer of pollutants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A model based on chemical structure was developed for the accurate prediction of octanol/water partition coefficient (K OW) of polychlorinated biphenyls (PCBs), which are molecules of environmental interest. Partial least squares (PLS) was used to build the regression model. Topological indices were used as molecular descriptors. Variable selection was performed by Hierarchical Cluster Analysis (HCA). In the modeling process, the experimental K OW measured for 30 PCBs by thin-layer chromatography - retention time (TLC-RT) has been used. The developed model (Q² = 0,990 and r² = 0,994) was used to estimate the log K OW values for the 179 PCB congeners whose K OW data have not yet been measured by TLC-RT method. The results showed that topological indices can be very useful to predict the K OW.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although electrospray ionization mass spectrometry (ES-MS) has been extensively applied to study organic and biochemical species, it is also specially suitable to study inorganic and organo-metallic species. Such species, even those that are low-volatile or thermo-unstable, can be easily ionized or simply transferred from liquid to gas phase by electrospray. However, chemical transformations frequently occur during the process. This paper discusses the fundamental aspects of electrospray ionization as well as its analytical applicability to inorganic and organo-metallic species in order to spread the technique and make its characteristics more familiar to potential users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The violence derived from crimes involving firearms represents one of the main concerns of society. For this reason modern techniques have emerged in forensic science to identify suspects at crime scenes. This work describes a methodology to identify residues present in the hands of suspect by using a high resolution inductively coupled plasma mass spectrometry and collection procedure based on ethylenediaminetetraacetic acid (EDTA) solution as a complexing agent in moistened swabs. In order to distinguish real gunshot residues from others types of residues present in the hand of suspect, ternary ratio per cent diagrams were developed for antimony (Sb), barium (Ba) and lead (Pb) detected on the hands of volunteers, before and immediately after shooting tests, revealing a remarkable difference in both situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study the factors that affect the extraction of pesticide residues from water samples for their determination by solid-phase micro-extraction (SPME) and GC/MS were optimized. The fiber polymer, the extraction mode, the ionic strength, the stirring rate, the pH and the extraction time were the most significant parameters evaluated. The recovery obtained with the proposed method ranged from 94 to 110% and the sensitivity of the method, determined by calculating the detection limit (DL), ranged from 0.004 to 0.1 mug l-1. The results obtained with spiked real samples, at the 0.1 mug l-1 level, showed acceptable conformity with the expected values.