547 resultados para Método MCMC a doisestágios


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports the preparation, characterization and study of the ion exchange behavior of hydrous niobium oxide prepared by a homogeneous precipitation method. The precipitating agent was obtained in aqueous solution by thermal decomposition of urea or ammonium carbonate. The compounds were chemically and physically characterized by X-ray diffractometry, thermal analysis (TG/DTG), surface area measurements and ion exchange behavior with sodium. The materials prepared with ammonium carbonate presented a higher degree of crystallinity and better ion exchange capacity with sodium than materials prepared with urea. In the homogeneous precipitation method, materials were obtained with specific surface area of 123 - 224 m² g-1. A variation of the preparation process produced hydrous niobium oxide with a different degree of hydration and specific surface area. This provided materials with different physico-chemical properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents an alternative method for determination of the herbicides tebuthiuron and hexazinone in ground water. The extraction was made with dichloromethane and the analyses by high performance liquid chromatography (HPLC), using reversed-phase column, C-18, mobile phase methanol/water 50:50, v/v, detection and quantification at 247 nm. The following validation parameters were obtained: limit of detection of method 0.02 and 0.03 µg L-1, limit of quantification of method 0.07 and 0.09 µg L-1; linear range limit of quantification of instrument - 300 µg L-1 (r² > 0.998); recoveries from 90.3 to 108.2% and 90.3 to 101.6%; intermediary precision (%RSD) < 8 and < 6%, for hexazinone and tebuthiuron, respectively. The method showed to be efficient and reliable for determination of the herbicides in ground water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glass ionomer cements are glass and polymer composite materials. These materials currently find use in dentistry. The purpose of this work is to obtain glass powders based on the composition 4.5SiO2 - 3Al2O3 - 2CaO to be used in dentistry. The powders were prepared by a chemical route at 700 0C. The properties of glass ionomer cements obtained from powders prepared at 700 ºC were studied. Diametral tensile strength and microhardness were evaluated for the experimental glass ionomer cements and a commercial material. It was concluded that the properties of experimental cements were similar to those of the commercial ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several extraction procedures are described for the determination of exchangeable and fixed ammonium, nitrate + nitrite, total exchangeable nitrogen and total nitrogen in certified reference soils and petroleum reservoir rock samples by steam distillation and indophenol method. After improvement of the original distillation system, an increase in worker safety, a reduction in time consumption, a decrease of 73% in blank value and an analysis without ammonia loss, which could possibly occur, were achieved. The precision (RSD < 8%, n = 3) and the detection limit (9 mg kg-1 NH4+-N) are better than those of published procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ONIOM method was used to calculate the proton affinities (PA) of n-alkylamines (CnH2n+1NH2, n = 3 to 6, 8, 10, 12, 14, 16 and 18). The calculations were carried out at several levels (HF, MP2, B3LYP, QCISD(T), ...) using Pople basis sets and at the QCISD(T) level using basis sets developed by the generator coordinate method (GCM) and adapted to effective core potentials. PAs were also obtained through the GCM and high level methods, like ONIOM[QCISD(T)/6-31+G(2df,p):MP2/6-31G+G(d,p))//ONIOM[MP2/6-31+G(d,p):HF/6-31G]. The average error using the GCM, with respect to experimental data, was 3.4 kJ mol-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel and quantitative mass spectrometry methods for rapid and accurate enantiomeric excess determination are presented. These methodologies use electrospray ionization (ESI) and mass spectrometry (MS) to detect and analyze, via collision-induced dissociation (CID), mass-selected transition metal complexes that promote enantio especific interactions. The data from CID are conveniently treated by the kinetic method, a sensitive linear free energy method of treating mass spectrometric results. Four different variations of this methodology are described: single ratio method (S R), quotient ratio method (Q R), fixed ligand method (S Rfixed), and quotient ratio method with fixed ligand (Q Rfixed). These individual methods are compared and their main features discussed in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Residual CuSO4 was incorporated into the mass utilized for cement preparation. To a cement mass with 1:0.5:5 of cement, lime and sand to 0.25, 0.50, 0.75 and 1.00% of residual CuSO4 were added. The sulfate was mixed separately with lime and water to induce metal precipitation. The hardened test bodies were submerged in Milli-Q water for three months. No Cu was detected in the water by Atomic Absorption Spectrometry. The best proportion for mechanical resistance and porosity is 0.50%. The cement is adequate for non-structural objects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of residues of the major groups of pesticides (organohalogen, organophosphorous, pyrethroids and organonitrogen) in representative samples of honey produced in Bauru (state of São Paulo, Brazil) was investigated from 1999 through2004. A multiresidue method was applied to honey samples to determine 48 pesticides with recoveries ranging from 76 to 95%. The limits of detection found were lower than 10 µg/kg for GC-MS-SIM. The results indicated that most pesticides found in the samples belonged to the organohalogen and organonitrogen groups. Residues of malathion were detected in almost all of the samples in high concentration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a simple and sensitive procedure to extract organic mercury from water and sediment samples, using methylene chloride in acidic media followed by CVAFS quantification has been developed. The method was evaluated for possible interferents, using different inorganic mercury species and humic acid, no effects being observed. The detection limit for organic mercury was 160 pg and 396 pg for water and sediment samples respectively. The accuracy of the method was evaluated using a certified reference material of methylmercury (BCR-580, estuarine sediment). Recovery tests using methylmercury as surrogate spiked with 1.0 up to 30.0 ng L-1 ranged from 90 up to 109% for water samples, whereas for sediments, recoveries ranged from 57 up to 97%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and efficient method for the analysis of histamine in wines using HPLC with fluorescence detection after derivatization was developed and validated. The method LOD and LOQ values were 0.25 and 0.50 mg L-1 respectively. The repeatability and intermediary precision for the instrument and for the method presented RSD values of 3.7 and 2.9%, and 6.0 and 5.6%, respectively. The recoveries were 95.5 and 89.9% for the fortification levels of 2 and 10 mg L-1. The method was applied to determine the histamine content in Cabernet Sauvignon wines, which presented values between 1.2 and 5.7 mg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validation of analytical methods was carried out for di-(ethylhexyl) phthalate (DEHP) and adipate (DEHA) the determination of in PVC films. The level of DEHP and DEHA in samples was determined by leaving the film in contact with n-heptane during 48 hours and analysis in a gas chromatograph (GC) equipped with a flame ionization detector and fused silica column with 5% phenylmethyl silicone in the dimensions 30 m x 0.53 mm x 2.65 mm. The results for detection and the quantification limits were smaller than the restriction limits. The recovery rates of DEHP and DEHA were, respectively, 69.10 and 75.30 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ilex paraguariensis A. St. -Hil. is a native species of southern South America. The caffeine content in Ilex paraguariensis leaves has been considered an important quality parameter for maté-derived products. In this work different extraction methods for the determination of these methylxantines are compared. The influence of the extraction conditions on the methylxanthine yields was evaluated. Extraction by decoction with acidic aqueous solution (H2SO4 4N) presented the higher efficiency in the theobromine extraction. The extraction in a Soxhlet with acidic aqueous solution and decoction with acidic aqueous solution showed the highest caffeine yield. For the concomitant theobromine and caffeine quantification, the decoction with acidic aqueous solution is suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new titrimetric method for the determination of phosphite in fertilizer samples, based on reaction of H3PO3 with standard iodine solution in neutral media, is proposed. Diluted samples containing ca. 0.4% m/v P2O5 are heated and titrated with 0.05 mol L-1 iodine standard until the solution becomes faint yellow. Back titration is also feasible: a slight excess of titrant is added followed by starch indicator and titration is completed taking as the end point the change in color from blue to colorless. The influence of chemical composition and pH of buffers, temperature and foreign species on waiting time and end-point detection were investigated. For the Na2HPO4/NaH2PO4 buffer (pH 6.8) at 70 °C, the titration time was 10 min, corresponding to about 127 mg iodine, 200 mg KI and 174 mg Na2HPO4 and 176 mg NaH2PO4 consumed per determination. Accuracy was checked for phosphite determination in seven fertilizer samples. Results obtained by the proposed procedure were in agreement with those obtained by spectrophotometry at 95% confidence level. The R.S.D. (n=10) for direct and back titration was 0.4% and 1.3% respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main analytical variables of a modified Folin-Ciocalteu method were studied by UV-Vis and gradient HPLC-PDA methods, using purified (PC) and technical grade (TGC) casein. Rutin and an aqueous extract of Psidium guajava L. leaves were used as models. The best results were ascribed to TGC. Certainly PC bonds the polyphenols of the P. guajava extract better than TGC, but TGC afforded better precision. A lack of specificity occurred when rutin was analyzed together with the P guajava extract. Additional analyses performed with the flavonoid fraction of P. guajava extract by HPLC-PDA had confirmed that casein was able to bind catechin, gallic acid and P. guajava flavonoids in a non-specific way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a method was developed for removing metallic ions from wastewaters by co-precipitation of Cu2+, Pb2+, Cd2+, Cr3+ and Hg2+ with chitosan and sodium hydroxide solution. Solutions of these metallic ions in the range from 0.55 to 2160 mg L-1 were added to chitosan dissolved in 0.05 mol L-1 HCl. For the co-precipitation of metal-chitosan-hydroxide a 0.17 mol L-1 NaOH solution was added until pH 8.5-9.5. A parallel study was carried out applying a 0.17 mol L-1 NaOH solution to precipitate those metallic ions. Also, a chitosan solid phase column was used for removing those metallic ions from wastewaters.