567 resultados para Alves, José Carlos Moreira
Resumo:
Intracoronary brachytherapy using beta or gamma radiation is currently the most efficient type of therapy for preventing the recurrence of coronary in-stent restenosis. Its implementation depends on the interaction among interventionists, radiotherapists, and physicists to assure the safety and quality of the method. The authors report the pioneering experience in Brazil of the treatment of 2 patients with coronary in-stent restenosis, in whom beta radiation was used as part of the international multicenter randomized PREVENT study (Proliferation REduction with Vascular ENergy Trial). The procedures were performed rapidly and did not require significant modifications in the traditional techniques used for conventional angioplasty. Alteration in the radiological protection devices of the hemodynamic laboratory were also not required, showing that intracoronary brachytherapy using beta radiation can be incorporated into the interventional tools of cardiology in our environment.
Resumo:
A woman aged 98 years entered the tertiary hospital service with a picture of acute myocardial infarction of the extensive anterior wall, which began 4 hours earlier. Due to the large myocardial risk area suggested by the electrocardiogram, the patient was taken to the hemodynamics laboratory for the performance of emergency coronary arteriography, which revealed occlusion in the proximal third of the anterior descending artery. Primary angioplasty followed by stent grafting was successfully performed. The patient had a satisfactory evolution (Killip I) and was discharged from the hospital on the seventh postinfarction day. We discuss here aspects of thrombolysis and coronary percutaneous interventions in the aged.
Resumo:
OBJECTIVE: To assess structural and functional cardiac changes in asymptomatic pregnant women with chronic arterial hypertension (CAH). METHODS: One hundred pregnant women with CAH underwent conventional Doppler echocardiography. The Student t test was used to compare them with 29 normotensive pregnant women (NT) in their third gestational trimester. RESULTS: Systolic (SBP; mmHg) and diastolic (DBP; mmHg) blood pressure values were higher (p<0.001) in the CAH pregnant women (SBP: 139±19 and DBP: 92± 18) as compared with those of the NT group (SBP: 112±10 and DBP: 74±9). A significant enlargement of the left atrium (4.10±0.48 cm vs 3.6±0.3 cm; p<0.001) and of the left ventricular normalized mass (59.6±19.7 g/cm2,7 vs 41.9±3.4 g/cm2,7; p<0.001) was observed. Cardiac output (CO, L/min) and systolic volume (SV, mL) were significantly higher in the CAH group (CO: 6.0±1.54 vs 4.9±2.1, p<0.01; SV: 77.3±19.8 vs 56.5±25.8, p<0.001). CONCLUSION: Chronic hypertensive pregnant women have structural and functional cardiac changes that justify routine cardiologic assessment, even in the absence of cardiopulmonary symptoms.
Resumo:
OBJECTIVE: To determine whether recording of the activation potential may be used as an isolated criterion to guide catheter ablation of atriofascicular Mahaim fibers. METHODS: We studied 6 patients (5 females, mean age of 26±7.3 years) with paroxysmal tachycardias with a wide QRS complex, whose electrophysiological study diagnosed atriofascicular Mahaim fibers. Mapping and catheter ablation were performed in sinus rhythm, guided only by the recording of the activation potential of the fiber. RESULTS: Efficacy in ablation was achieved in all patients. The fibers were located in the right lateral region of the tricuspid ring in 3 patients, right posterolateral region in 2, and right anterolateral region in 1. A mean of 5.3±3 radiofrequency applications was performed. The mean fluoroscopy time was 46.6±25 minutes, and the mean duration of the procedure was 178.6±108 minutes. No complication occurred. In a mean 20-month follow-up, all patients were asymptomatic and receiving no antiarrhythmic drugs. CONCLUSION: Catheter ablation of Mahaim fibers may be performed with good safety and efficacy by mapping the activation potential of the tricuspid ring in sinus rhythm.
Resumo:
OBJECTIVE: To determine the levels of total cholesterol in a significant sample of the Brazilian population. METHODS: Blood cholesterol was determined in 81.262 individuals > 18 years old (51% male, 44.7 ± 15.7 years), using Accutrend equipment, in the cities São Paulo, Campinas, Campos do Jordão, São José dos Campos, Santos, Santo André, Ribeirão Preto, Porto Alegre, Rio de Janeiro, Belo Horizonte, Curitiba, Brasília, Salvador and documented in the presence of other risk factors (RF) for coronary artery disease (CAD) (systemic hypertension, CAD in the family, smoking, and diabetes). Participants were classified according to sex, age, and the presence or absence of RF, respectively, as 0 RF, 1 RF and > 2 RF. The percentage of individuals with cholesterol > 200 mg/dL and > 240 mg/dL was evaluated. RESULTS: The prevalence of individuals with 0, 1, and > 2 risk factors was 30% (n = 24,589), 36% (n =29,324), and 34% (n = 27,349) respectively, (P=0.657), and the mean total cholesterol of the population was 199.0 ± 35.0 mg/dL. Cholesterol levels above 200 and 240 mg/dL were found, respectively, in 40% (n = 32,515) and 13% (10.942) of individuals. The greater the number of risk factors the higher the levels of cholesterol (P<0.0001) and the greater the proportion of individuals with cholesterol > 200 mg/dL (P=0.032). No difference existed in the proportion of individuals with cholesterol > 240 mg/dL (P=0.11). CONCLUSION: A great percentage of individuals with cholesterol levels above those recommended to prevent coronary artery disease was found.
Resumo:
OBJETIVO: Determinar os resultados em longo prazo da valvoplastia percutânea por balão em uma instituição isolada. MÉTODOS: Estudados 189 pacientes com estenose valvar pulmonar submetidos a valvoplastia percutânea por balão, entre 1984-1996, com idade média de 7,97±9,25 anos, classificando-se como bem sucedida, a redução do gradiente VD-AP em níveis < 36mmHg e reestenose gradientes > 36mmHg após procedimento eficaz. RESULTADOS: Após o término do procedimento, o gradiente pico a pico transvalvar reduziu-se de 70,12±30,06 para 25,11±20,23 mmHg (p<0,001). Obtiveram sucesso imediato 148 (78,72%) pacientes. Houve redução posterior do gradiente para valores < 36mmHg em outros 24 pacientes categorizados sem sucesso no grupo. Assim a valvoplastia percutânea por balão foi considerada efetiva em 172 (91,01%) pacientes. A efetividade aumentou para 93,53% (159/170) nos casos de morfologia típica. O tempo de seguimento foi de 4,39±3anos até o período máximo de 13,01 anos. Observou-se reestenose em 24 (13,95%). A presença de regurgitação pulmonar foi detectada em 95,1% dos pacientes, sendo que em 29,5% com grau maior do que leve. A probabilidade de se manter um resultado adequado, até qualquer ponto no tempo, sem a ocorrência de reestenose, foi de 92,29% em 2 anos, de 87,38 % em 5 anos, de 82,46% em 8 anos e de 64,48% em 10 anos. CONCLUSÃO: A valvoplastia percutânea por balão foi efetiva e segura no tratamento da estenose valvar pulmonar com excelentes resultados imediatos e a longo prazo.
Resumo:
OBJETIVO: Descrever os achados clínicos e ecocardiográficos de trombose em prótese biológica mitral e o valor do ecocardiograma transesofágico (ETE) no diagnóstico e monitoração da lise do trombo. MÉTODOS: Foram estudados ao ETE 111 pacientes com prótese biológica mitral, e incluídos 4 de 7 com suspeita de trombo nestas próteses (idade média = 60,2±10,2 anos; 2 homens). O diagnóstico pôde ser confirmado pela realização seriada do ETE e pela evolução clínica. Investigaram-se os aspectos morfológicos dos folhetos da prótese, e presença e característica das massas ecogênicas anexas. Foram obtidos o gradiente médio pela prótese e a área valvar. RESULTADOS: O diagnóstico de trombo em prótese biológica mitral foi realizado 48,7±55,2 meses após a cirurgia. Dois pacientes apresentaram acidente vascular encefálico isquêmico no pós-operatório imediato. O gradiente médio global estava elevado (11,4±3 mmHg) e a área valvar reduzida (1,24±0,3cm²). Ao ETE, em todos foram evidenciadas massas ecogênicas em face ventricular esquerda da prótese biológica mitral, sugestivas de trombo. No ETE seriado (136±233 dias), houve desaparecimento do trombo em dois casos e redução do trombo nos outros dois, após tratamento. O gradiente médio reduziu para 6,2±3 mmHg (p=0,004; IC 95%), e a área valvar aumentou para 2,07±0,4 (p=ns). CONCLUSÃO: O ETE mostrou-se útil na detecção de trombo em prótese biológica mitral e eficaz na monitoração do tratamento, em todos casos.
Resumo:
OBJETIVO: Determinar a correlação entre as velocidades diastólicas do Doppler tissular com a idade em amostra de adultos saudáveis, e correlacionar a idade com as velocidades do fluxo transmitral e de veias pulmonares. MÉTODOS: Estudados, através da ecocardiografia, 51 indivíduos saudáveis, com idades entre 21 e 69 anos e registradas as velocidades miocárdicas diastólicas ao Doppler tissular e determinadas as velocidades dos fluxos transmitral e venoso pulmonar. RESULTADOS: As velocidades miocárdicas diastólicas iniciais septal basal e lateral basal apresentaram correlação inversa com a idade, com r = - 0,40 (p = 0,004) e r = - 0,60 (p = 0,0001) respectivamente. As velocidades atriogênicas do Doppler tissular foram diretamente correlacionadas com a idade, sendo no segmento septal basal r = 0,56 (p = 0,0001) e no segmento lateral basal r = 0,50 (p = 0,0001). As velocidades do fluxo transmitral e do fluxo venoso pulmonar também mostraram correlação com a idade. CONCLUSÃO: Existe correlação entre a idade e as velocidades miocárdicas diastólicas do Doppler tissular e com as velocidades do fluxo transmitral e fluxo venoso pulmonar, demonstrando em indivíduos saudáveis uma variação de parâmetros da função diastólica do ventrículo esquerdo com a evolução natural da idade.