82 resultados para validation of methods
Resumo:
A simple and rapid precipitation titration method was developed and validated to determine sulfate ion content in indinavir sulfate raw material. 0.1 mol L-1 lead nitrate volumetric solution was used as titrant employing potentiometric endpoint determination using a lead-specific electrode. The United States Pharmacopoeia Forum indicates a potentiometric method for sulfate ion quantitation using 0.1 mol L-1 lead perchlorate as titrant. Both methods were validated concerning linearity, precision and accuracy, yielding good results. The sulfate ion content found by the two validated methods was compared by the statistical t-student test, indicating that there was no statistically significant difference between the methods.
Resumo:
A gas chromatographic method has been developed for the assay of fluvastatin sodium (FLU). FLU was silylated with N,O-bis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 90 ºC for 30 min and analysed in a DB-1 column by capillary gas chromatograph with a flame ionization detector. The method was validated. The assay was linear over the concentration range at 10.0 to 50.0 µg mL-1. The limit of detection and the limit of quantitation were 1.0 and 3.0 µg mL-1, respectively. The recoveries of FLU derivatives were in the range of 99.25-99.80%. In inter-day and intra-day analysis, the values of relative standard deviation (%) and the relative mean error (%) were found between 0.20-0.80% and -0.20-0.75%, respectively. The developed method was succesfully applied to analyze the FLU content in tablet formulation. The results were statistically compared with those obtained by the official method, and no significant difference was found between the two methods. Therefore, it can be recommended for the quality control assay of FLU in pharmaceutical industry.
Resumo:
A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.
Resumo:
A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.
Resumo:
Scarcity of long-term series of sediment-related variables has led watershed managers to apply mathematical models to simulate sediment fluxes. Due to the high efforts for installation and maintenance of sedimentological gauges, tracers have been pointed out as an alternative to validate soil redistribution modelling. In this study, the 137Cs technique was used to assess the WASA-SED model performance at the Benguê watershed (933 km²), in the Brazilian semiarid. Qualitatively, good agreement was found among the 137Cs technique and the WASA-SED model results. Nonetheless, quantitatively great differences, up to two orders of magnitude, were found between the two methods. Among the uncertainties inherent to the 137Cs technique, definition of the reference inventory seems to be a major source of imprecision. In addition, estimations of water and sediment fluxes with mathematical models usually also present high uncertainty, contributing to the quantitative differences of the soil redistribution estimates with the two methods.
Resumo:
Objective: To develop and validate an instrument for measuring the acquisition of technical skills in conducting operations of increasing difficulty for use in General Surgery Residency (GSR) programs. Methods: we built a surgical skills assessment tool containing 11 operations in increasing levels of difficulty. For instrument validation we used the face validaity method. Through an electronic survey tool (Survey MonKey(r)) we sent a questionnaire to Full and Emeritus members of the Brazilian College of Surgeons - CBC - all bearers of the CBC Specialist Title. Results: Of the 307 questionnaires sent we received 100 responses. For the analysis of the data collected we used the Cronbach's alpha test. We observed that, in general, the overall alpha presented with values near or greater than 0.70, meaning good consistency to assess their points of interest. Conclusion: The evaluation instrument built was validated and can be used as a method of assessment of technical skill acquisition in the General Surgery Residency programs in Brazil.
Resumo:
ABSTRACT The objective of this work was to study the distribution of values of the coefficient of variation (CV) in the experiments of papaya crop (Carica papaya L.) by proposing ranges to guide researchers in their evaluation for different characters in the field. The data used in this study were obtained by bibliographical review in Brazilian journals, dissertations and thesis. This study considered the following characters: diameter of the stalk, insertion height of the first fruit, plant height, number of fruits per plant, fruit biomass, fruit length, equatorial diameter of the fruit, pulp thickness, fruit firmness, soluble solids and internal cavity diameter, from which, value ranges were obtained for the CV values for each character, based on the methodology proposed by Garcia, Costa and by the standard classification of Pimentel-Gomes. The results obtained in this study indicated that ranges of CV values were different among various characters, presenting a large variation, which justifies the necessity of using specific evaluation range for each character. In addition, the use of classification ranges obtained from methodology of Costa is recommended.
Resumo:
Epidemiological studies of drug misusers have until recently relied on two main forms of sampling: probability and convenience. The former has been used when the aim was simply to estimate the prevalence of the condition and the latter when in depth studies of the characteristics, profiles and behaviour of drug users were required, but each method has its limitations. Probability samples become impracticable when the prevalence of the condition is very low, less than 0.5% for example, or when the condition being studied is a clandestine activity such as illicit drug use. When stratified random samples are used, it may be difficult to obtain a truly representative sample, depending on the quality of the information used to develop the stratification strategy. The main limitation of studies using convenience samples is that the results cannot be generalised to the whole population of drug users due to selection bias and a lack of information concerning the sampling frame. New methods have been developed which aim to overcome some of these difficulties, for example, social network analysis, snowball sampling, capture-recapture techniques, privileged access interviewer method and contact tracing. All these methods have been applied to the study of drug misuse. The various methods are described and examples of their use given, drawn from both the Brazilian and international drug misuse literature.
Resumo:
The aim of this study was to validate the 14C-urea breath test for use in diagnosis of Helicobacter pylori infection. Thirty H. pylori positive patients, based on histologic test and thirty H. pylori negative patients by histology and anti-H. pylori IgG entered the study. Fasting patients drank 5 uCi of 14C-urea in 20 ml of water. Breath samples were collected at 0, 5, 10, 15, 20 and 30 min. The difference of cpm values between the two groups was significant at all the time intervals, besides time 0 (p<0.0001). At 20 min, the test gave 100% sensitivity and specificity with a cut-off value of 562 cpm. Females were higher expirers than males (p=0.005). 14C-urea breath test is highly accurate for Helicobacter pylori diagnosis. It is fast, simple and should be the non-invasive test used after treating Helicobacter pylori infection.
Resumo:
The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.
Canine visceral leishmaniasis: study of methods for the detection of IgG in serum and eluate samples
Resumo:
The Brazilian Ministry of Health recommends the culling and euthanasia of dogs with a positive serological test for canine visceral leishmaniasis (CVL). In the Municipality of Rio de Janeiro, the technique used for the diagnosis of CVL is the indirect fluorescent antibody test (IFAT), using blood samples eluted on filter paper (eluate). A dog survey was conducted over a period of one year in the region of Carapiá, in order to evaluate the diagnosis of CVL in this region. All animals underwent clinical examination, and blood samples (serum and eluate) were collected for analysis by enzyme immunoassay (ELISA) and IFAT. A skin biopsy was obtained for parasitological examination (culture). A total of 305 animals were studied and Leishmania chagasi was isolated from nine animals. Sensitivity and specificity were 100% and 96.6% for ELISA, respectively, 100% and 65.5% for IFAT (cut-off at a 1:40 dilution), 100% and 83.4% for IFAT (cut-off at a 1:80 dilution), and 22.2% and 97.0% for eluate IFAT. In conclusion, ELISA was the best tool for the diagnosis of CVL among the serological techniques tested. The present results suggest the need for a better evaluation of filter paper IFAT as the only diagnostic method for CVL in the Municipality of Rio de Janeiro.
Resumo:
INTRODUCTION: Methicillin-Resistant Staphylococcus aureus (MRSA) presenting reduced susceptibility to vancomycin has been associated to therapeutic failure. Some methods used by clinical laboratories may not be sufficiently accurate to detect this phenotype, compromising results and the outcome of the patient. OBJECTIVES: To evaluate the performance of methods in the detection of vancomycin MIC values among clinical isolates of MRSA. MATERIAL AND METHODS: The Vancomycin Minimal Inhibitory Concentration was determined for 75 MRSA isolates from inpatients of Mãe de Deus Hospital, Porto Alegre, Brazil. The broth microdilution (BM) was used as the gold-standard technique, as well as the following methods: E-test® strips (BioMérieux), M.I.C.E® strips (Oxoid), PROBAC® commercial panel and the automated system MicroScan® (Siemens). Besides, the agar screening test was carried out with 3 µg/mL of vancomycin. RESULTS: All isolates presented MIC ≤ 2 µg/mL for BM. E-test® had higher concordance (40%) in terms of global agreement with the gold standard, and there was not statistical difference among E-test® and broth microdilution results. PROBAC® panels presented MICs, in general, lower than the gold-standard panels (58.66% major errors), while M.I.C.E.® MICs were higher (67.99% minor errors). CONCLUSIONS: For the population of MRSA in question, E-test® presented the best performance, although with a heterogeneous accuracy, depending on MIC values.
Resumo:
Mangoes, cv. Imperial, were exposed, in post harvest, to the following methods of ripening: 1) sawdust burning; 2) alcohol vaporization; 3) calcium carbide (acetylene), 4) vapour of ethylene; and, 5) immersion in ethefon. All methods resulted in acceleration of ripening, when compared to controls. Calcium carbide, ethelene and ethefon were the best, methods. Alcohol vaporization also showed good results sawdust burning method showing low efficiency.
Resumo:
In the estuary of the Mamanguape River (Paraíba, Brazil), a new collection technique was developed and applied with virgin poles of mangrove trees Avicennia schaueriana (Verbenaceae), Rhizophora mangle (Rhizophoraceae), and Laguncularia racemosa (Combretaceae), taking into account wood preference, water salinity and depth influence during teredinid larval settlement. Sets of poles were vertically fixed in the riverbed at three sites along a decreasing salinity gradient, where they stayed for four months. The poles were collected and divided into upper, median, and lower segments, in agreement with different immersion regimes. An increase of 239% was obtained in the number of individuals when compared to a previous study in the same area using a different methodology. The species Teredo bartschi (Clapp, 1923), Nausitora fusticula (Jeffreys, 1860) and Bankia fimbriatula Moll & Roch, 1931 were registered in both studies, and the species Psiloteredo healdi (Bartsch, 1931) is here registered for the first time as occurring in that estuary. The species Neoteredo reynei (Bartsch, 1920), previously registered on tree branches of the mangrove habitat, was not found in the present work. Bankia fimbriatula, the most abundant species, did not show preference for any substratum but occurred significantly on the lower segment of the poles. N. fusticula, second in abundance, preferred to settle on poles of A. schaueriana and on any of the three segments. Aiming to assess the habitat variations, a more accurate study on teredinids diversity in mangrove ecosystems should be performed through a concomitant analysis from tree branches of the mangrove habitat, as well as from poles of mangrove trees or panels made of pine wood or mangrove trees wood. These collection devices should be maintained along a decreasing salinity gradient exposed to different tide levels.