25 resultados para tungsten bronze


Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is here discussed the development of a low cost analytical instrument with capacity for metals determination using atomic emission measurements in an electrothermal atomization system with a tungsten coil atomizer. The main goal was to show a new frontier for using this atomizer and to demonstrate that the simple instrumental arrangement here proposed has potential for portability and for solving analytical tasks related to metals determination. Atomic emission of calcium was selected for the adjustment of instrumental parameters and to evaluate the main characteristics of the lab-built instrument. Cobalt was determined in medicines and one alloy to demonstrate its feasibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report results of the efficiency of tungsten extraction from wolframite concentrate (containing 61.5 wt % WO3) from the Igarapé Manteiga mine (state of Rondônia, Brazil) through acid leaching with strong mineral acids at 100 ºC and 400 rpm for 2-4 h. HCl yielded insoluble matter containing the highest WO3 content (90 wt %). This solid was dissolved in concentrated NH3(aq) at 25 ºC and the insoluble matter filtrated. The filtrate was slowly evaporated. 70 wt % of the tungsten present in the starting concentrate material was recovered as ammonium paratungstate (APT).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spent oxidized (500 ºC, 5 h) commercial NiW/Al2O3 catalysts were processed using two different routes: a) fusion with NaOH (650 ºC, 1 h), the roasted mass was leached in water; b) leaching with HCl or H2SO4 (70 ºC, 1-3 h). HCl was the best leachant. In both routes, soluble tungsten was extracted at pH 1 with Alamine 336 (10 vol.% in kerosene) and stripped with 2 mol L-1 NH4OH (25 ºC, one stage, aqueous/organic ratio = 1 v/v). Tungsten was isolated as ammonium paratungstate at very high yield (> 97.5%). The elements were better separated using the acidic route.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method has been developed for the simultaneous determination of Cd and Pb in antibiotics used in sugar-cane fermentation by GFAAS. The integrated platform of transversely heated graphite atomizer was treated with tungsten to form a coating of tungsten carbide. Six samples of commercial solid antibiotics were analyzed by injecting 20 µL of digested samples into the pretreated graphite platform with co-injection of 5 µL of 1000 mg L-1 Pd as chemical modifier. Samples were mineralized in a closed-vessel microwave-assisted acid-digestion system using nitric acid plus hydrogen peroxide. The pyrolysis and atomization temperatures of the heating program of the atomizer were selected as 600°C and 2200°C, respectively. The calculated characteristic mass for Cd and Pb was 1.6 pg and 42 pg, respectively. Limits of detection (LOD) based on integrated absorbance were 0.02 µg L-1 Cd and 0.7 µg L-1 Pb and the relative standard deviations (n = 10) for Cd and Pb were 5.7% and 8.0%, respectively. The recoveries of Cd and Pb added to the digested samples varied from 91% to 125% (Cd) and 80% to 112% (Pb).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Durante o período de janeiro de 1994 a janeiro de 1997 foram submetidos ao método 120 pacientes, sendo 42 do sexo masculino (35%) e 78 do sexo feminino (65%). A idade variou de 16 a 60 anos, com média de 38. Todos apresentavam diagnóstico de colecistite calculosa crônica, sendo selecionados em consultório pelos seguintes critérios: inexistência de quadro inflamatório agudo da vesícula biliar, idade máxima de 60 anos, ausência de suspeita de coledocolitíase e classificação anestésica ASA I e II. A cirurgia era realizada em posição semiginecológica com utilização de três trocartes, sendo a colangiografia realizada de rotina. O tempo cirúrgico variou de 20 a 80 minutos com média de 50 minutos. A colangiografia intra-operatória foi realizada em 105 pacientes (87,5%), demonstrando coledocolitíase em dois (1,9%). Não ocorreram conversões. As complicações pós-operatórias imediatas mais freqüentes foram náuseas em oito casos (6,6%), seguidas de vômitos em dois pacientes (1,6%). A dor foi de pequena intensidade e facilmente controlável com dipirona e antiintlamatórios não-hormonais. Não ocorreram casos de infecção de ferida cirúrgica, mas três pacientes (2,5%) apresentaram hiperemia da incisão umbilical. Todos tiveram condições de alta no mesmo dia da cirurgia. O período de permanência hospitalar foi em média de 10 horas. Não houve necessidade de reinternação em nenhum caso.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Self-fluxed nickel alloys are usually flame fused after thermal spraying. However, due to the practical aspects of high temperatures reached during flame fusing, large structures such as the hydraulic turbines for power generation, can not be efficiently coated. An alternative is to fuse the sprayed coating with a gas tungsten electric arc. In this case, heating is much more intensive and substrate temperature during and after the fusing operation is much lower, thus reducing the possibility that any problem will occur. In this work, coatings of self-fluxed nickel alloy fused by flame and gas tungsten arc were evaluated as protection of hydraulic turbines against cavitational damage. Several tests were performed, including the ASTM ultrasonically vibration-induced cavitation, optical and scanning electronic microscopic metallography, and hardness tests. The results showed that the arc-fused coating presented better cavitation damage resistance, probably due to its finer microstructure. A field application of this new technique is also described. A self-fluxed Ni alloy was flame sprayed in critical regions of Francis-type hydraulic turbine blades and fused by a gas tungsten arc after spraying. The blades will be inspected during the next two years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current methods for recording field potentials with tungsten electrodes make it virtually impossible to use the same recording electrode also as a lesioning electrode, for example for histological confirmation of the recorded site, because the lesioning procedure usually wears off the tungsten tip. Therefore, the electrode would have to be replaced after each lesioning procedure, which is a very high cost solution to the problem. We present here a low cost, easy to make, high quality glass pipette-carbon fiber microelectrode that shows resistive, signal/noise and electrochemical coupling advantages over tungsten electrodes. Also, currently used carbon fiber microelectrodes often show problems with electrical continuity, especially regarding electrochemical applications using a carbon-powder/resin mixture, with consequent low performance, besides the inconvenience of handling such a mixture. We propose here a new method for manufacturing glass pipette-carbon fiber microelectrodes with several advantages when recording intracerebral field potentials

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the GABA-induced inactivation of V2 neurons and terminals on the receptive field properties of this area in an anesthetized and paralyzedCebus apella monkey. Extracellular single-unit activity was recorded using tungsten microelectrodes in a monkey before and after pressure-injection of a 0.25 or 0.5 M GABA solution. The visual stimulus consisted of a bar moving in 8 possible directions. In total, 24 V2 neurons were studied before and after blocker injections in 4 experimental sessions following GABA injection into area V2. A group of 10 neurons were studied over a short period. An additional 6 neurons were investigated over a long period after the GABA injection. A third group of 8 neurons were studied over a very long period. Overall, these 24 neurons displayed an early (1-20 min) significant general decrease in excitability with concomitant changes in orientation or direction selectivity. GABA inactivation in area V2 produced robust inhibition in 80% and a significant change in directional selectivity in 60% of the neurons examined. These GABA projections are capable of modulating not only levels of spontaneous and driven activity of V2 neurons but also receptive field properties such as direction selectivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99mTc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract A wide range of quality parameters have been used to describe maize flours for food use, but there is no general agreement about the most suitable parameters for breadmaking. The objective of this study was to identify the maize flour parameters related to the consumer perceived quality of Portuguese broa bread (more than 50% maize flour). The influence of eleven maize landraces was assessed and compared with commercial flour using baking tests. The broa were evaluated by instrumental (colour, firmness) and sensory hedonic analysis with a consumer panel of 52 assessors. The broa sensory analysis revealed similar assessments among landraces and the lowest scores for commercial flour. The flour particle size distribution is the major influence, with commercial flour showing the highest mean diameter and a large particle distribution range. Broa consumer panel linkage associations and specific sensory descriptors have been identified; age as an influence on colour, cohesiveness, and source region as an influence on appearance and texture.