27 resultados para photoelectrochemical disinfection


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, TiO2 photocatalysis was used to disinfect domestic wastewaters previously treated by different biological treatment systems: Upward-flow Anaerobic Sludge Blanket (UASB), facultative pond, and duckweed pond. The microorganisms monitored were E. coli, total coliforms, Shigella species, and Salmonella species. Photocatalytic experiments were carried out using two light sources: a solar simulator (UV intensity: 68-70 W m-2) and black-light lamps (BLL UV intensity: 17-20 W m-2). Samples were taken after each treatment stage. Results indicate that bacterial photocatalytic inactivation is affected by characteristics of the effluent, including turbidity, concentration of organic matter, and bacterial concentration, which depend of the type of biological pretreatment previously used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work TiO2 films were formed over Indium Tin Oxide (ITO) employing cathodic electrophoretic deposition (Cathodic-EPD) and Dr. Blade Technique. The films were characterized by electrochemical techniques in order to compare their electronic properties; as well as, their photoelectrochemical behavior. The electrochemical performance showed by the films, allowed to relate the modification occurring during the Cathodic-EPD, with the partial reduction of TiO2 nanoparticles, generating Ti3+ defects. These trapping states are modifying the electronic properties of the film, and diminishing the transport of the photoelectrogenerated electrons toward ITO.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Zn-TiO2nanocomposite films were prepared by electrodeposition, using an acidic zinc sulphate solution with TiO2 nanoparticles in suspension. The as-deposited samples have been heated in air at 450 ºC for 6 h. The XRD and SEM analyses pointed out to the metal matrix conversion from Zn to ZnO and a rich morphology of needles-shaped grains. These materials were used on the photoelectrochemical degradation of AO7, which was efficiently degraded, with 40% of color removal, after 2 h period at 1.0 V, under white light irradiation. The apparent first order rate constant of the photoelectrodegradation reaction was 4.12 x 10-3 min-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydrogen peroxide has been used for decades in developed countries as an oxidizing agent in the treatment of water, domestic sewage and industrial effluents. This study evaluated the influence of the concentration of H2O2 and pH on the inactivation of Escherichia coli cells and the disinfection of sewage treated. The results showed that the inactivation rate increased with pH and H2O2. The presence of other contaminants dissolved in the effluent is probably the cause of these differences, because E. coli inactivation in synthetic wastewater was found to be much faster than in the real treated domestic sewage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, photoelectrochemical solar cells based on bismuth tungstate electrodes were evaluated. Bi2WO6 was synthesized by a hydrothermal method and characterized by scanning electron microscopy, UV-Vis reflectance spectroscopy, and X-ray powder diffraction. For comparison, solar cells based on TiO2 semiconductor electrodes were evaluated. Photoelectrochemical response of Grätzel-type solar cells based on these semiconductors and their corresponding sensitization with two inexpensive phthalocyanines dyes were determined. Bi2WO6-based solar cells presented higher values of photocurrent and efficiency than those obtained with TiO2 electrodes, even without sensitization. These results portray solar cells based on Bi2WO6 as promising devices for solar energy conversion owing to lower cost of production and ease of acquisition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pathogens in maize (Zea mays) seeds cause serious problems, such as the loss of their capacity to germinative. The objectives of this study were to identify the optimal period for infection of maize seeds on agar colonized by Fusarium graminearum, when incubated for 4, 8, 16 and 32 h, and to evaluate the effect of the fungus on the germination and vigor of seeds with different infection levels. After the respective incubation periods, the seeds were removed from the culture medium and submitted to the blotter test for 3 min with and without superficial disinfection with 1% solution of sodium hypochlorite. Once the optimal period for seed incubation was identified, seeds from the same sample were again placed on the colonized agar for infection. Germination and vigor tests (accelerated aging and cold test) were performed with a mixture of healthy seeds (placed on PDA medium) and inoculated seeds, resulting in seeds with 0, 20, 40, 60, 80 and 100% rates of infection. The results showed that a period of 32 h was long enough to obtain seeds infected by the pathogen. There were no significant effects of fungal infection on seed germination at any of the infection levels, probably due to the high vigor of the maize seed lot tested. Regarding vigor tests, infection levels differed significantly from the control (0% infection), but there were no significant differences among the infection levels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Swine manure agricultural use is a common practice in Brazil. Their physic-chemical characteristics favor its use as biofertilizer, but the presence of pathogens may become a risk to human health. This research presents a qualitative study of the main alternatives of pig manure disinfection, analyzing efficiency, advantages and limitations of each procedure. The disinfection studies reported in literature are based on the following treatments: alkaline, thermal, biological, chemical, and physical. The greater efficiencies are in thermal treatment (> 4 log: 60 °C), chemical treatment (3 to 4 log: 30mg Cl- L-1; 3 to 4 log: 40 mg O3 L-1) and physical treatment (3 a 4 log: 220 mJ UV radiation cm-2). The biological treatment (anaerobiosis) also promotes the pathogen reduction of swine manure, however with lower efficiency (1 to 2 log). The selection of the treatment should consider: implementation and operation cost, necessity of preliminary treatment, efficiency obtained and destination of the treated manure (agricultural use, water reuse). Brazilian regulation does not have specific guidelines for the microbiological quality of animal production effluents that is very important to be considered due to confined animal feeding operation transformation in the last years in the country.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Between August 2006 and February 2007, in the state of Rio de Janeiro, Brazil, a massive outbreak of RGM infections after video laparoscopy was mainly associated to the recently described Mycobacterium massiliense species. All confirmed and probable cases reports described the use of high-level disinfection of medical devices by using 2% glutaraldehyde (2% GA) for 30 min before the surgical procedures. We investigated the susceptibility of the M. massiliense isolates recovered during the outbreak to high-level disinfection after 30 min, 1h, 6h and 10h of exposure to the commercial disinfectants. Reference strains for official mycobactericidal tests such as Mycobacterium abscessus, Mycobacterium bovis, Mycobacterium chelonae, Mycobacterium neoaurum and Mycobacterium smegmatis were included as controls. Although all the reference strains were eliminated in 30 min of exposure to 2% GA, we observed the recovery of all M. massiliense clinical isolates even after 10h of exposure. This study suggests that failures in high-level disinfection and the high tolerance of these M. massiliense clinical strains to the 2% GA were strongly associated to the magnitude of the outbreak.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapidly growing mycobacteria (RGM) are opportunistic microorganisms and widely distributed into aqueous environment and soil. Human RGM infections are usually associated with contaminated solutions or medical instruments used during invasive procedures. RGM postsurgical infections have recently emerged in Brazil and have caused national alert, considering the risk factors and epidemiological aspects. This study aimed at analysing the main factors linked to the recent RGM outbreaks, with focus on the national epidemic of Mycobacterium massiliense infections related to the BRA100 strains resistant to 2% glutaraldehyde commercial solutions commonly used for preoperative high-level disinfection. Based on previous studies and laboratorial results of assays and colaborations, it has been observed that the cases have been associated with videolaparoscopy for different applications and elective esthetic procedures, such as lipoaspiration and mammary prosthesis implant. Furthermore, outbreaks between 2004 and 2008 and the epidemic in Rio de Janeiro state may be considered particular Brazilian events. Although there are a few epidemiological published studies, some hypotheses based on common aspects related to most national nosocomial occurrences are possible, such as lack of protocols for cleaning and high-level disinfection, use of 2% glutaraldehyde as high-level disinfectant for surgical instruments, and dissemination of M. massiliense BRA100 by unknown mechanisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Few data are available in the literature concerning the efficacy of standard hysteroscope disinfection procedures to prevent hepatitis B transmission. The aim of the present study was to determine the risk of hepatitis B virus (HBV) transmission during hysteroscopy among anti-HBc-seropositive women. Serum and hysteroscopic samples were collected from 62 women after diagnostic hysteroscopy. All samples were tested for serologic HBV markers. Polymerase chain reactions (PCR) were carried out to amplify regions C and S of the viral genome and only samples amplified by both pairs of primers were considered to be positive. Anti-HBc was repeatedly reactive in 48 (77%) of 62 serum samples, and HBsAg was detected in 8 (13%). At least one HBV serologic marker was found in 49 (79%) samples. Only one sample was HBsAg positive and anti-HBc negative. HBV-DNA was detected by PCR in 7 serum samples but in only 3 hysteroscopic samples obtained just after hysteroscopy. It is noteworthy that high levels of anti-HBc IgM were detected in one HBsAg-negative patient who showed an HBV-DNA-positive hysteroscopic sample. An elevated sample/cut-off ratio for anti-HBc IgM suggests recent infection and reinforces the need for testing for HBsAg and anti-HBc before hysteroscopy, since acute hepatitis B can be clinically asymptomatic. Viral DNA was not detected in any hysteroscopic samples collected after washing and disinfecting procedures with glutaraldehyde. We conclude that HBV-DNA can be found in the hysteroscope soon after hysteroscopy, but standard disinfecting procedures are effective in viral removal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A photodynamic effect occurs when photosensitiser molecules absorb light and dissipate the absorbed energy by transferring it to biological acceptors (usually oxygen), generating an excess of reactive species that are able to force cells into death pathways. Several tropical diseases present physiopathological aspects that are accessible to the application of a photosensitiser and local illumination. In addition, disease may be transmitted through infected blood donations, and many of the aetiological agents associated with tropical diseases have been shown to be susceptible to the photodynamic approach. However, there has been no systematic investigation of the application of photoantimicrobial agents in the various presentations, whether to human disease or to the disinfection of blood products or even as photo-insecticides. We aim in this review to report the advances in the photoantimicrobial approach that are beneficial to the field of anti-parasite therapy and also have the potential to facilitate the development of low-cost/high-efficiency protocols for underserved populations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Antimicrobial activities of two commercial disinfectants, alone or combined with heat, against three Salmonella strains and three Listeria monocytogenes strains were studied. The efficacy of disinfectants against planktonic bacteria and bacteria attached to three food contact industrial surfaces (stainless steel, polytetraflourethylene, and rubber) was investigated. The tests were conducted using the sanitizer (quaternary ammonium compounds, and alquyldiethylenediamineglycine and di-alquyldiamineethylglycine) concentrations recommended by the manufacturers, and concentrations twice and four times higher than those values. The recommended concentrations were not effective to kill bacteria, especially when they were attached to surfaces. Concentrations of disinfectants twice and four times higher than those recommended were needed to fully eliminate planktonic bacteria. These same sanitizer concentrations were not sufficient to remove attached bacteria. To remove them from the surfaces, a treatment with recommended concentrations in combination with heat was needed. Our results indicate that these two pathogenic bacteria could survive common sanitation programs used in the food industry.