24 resultados para optical pupil filters with sine functions
Resumo:
ß-Glucans are soluble fibers with physiological functions, such as interference with absorption of sugars and reduction of serum lipid levels. The objective of the present study was to analyze the distribution of ß-glucans in different tissues of the African grass species Rhynchelytrum repens and also to evaluate their hypoglycemic activity. Leaf blades, sheaths, stems, and young leaves of R. repens were submitted to extraction with 4 M KOH. Analysis of the fractions revealed the presence of arabinose, glucose, xylose, and traces of rhamnose and galactose. The presence of ß-glucan in these fractions was confirmed by hydrolyzing the polymers with endo-ß-glucanase from Bacillus subtilis, followed by HPLC analysis of the characteristic oligosaccharides produced. The 4 M KOH fractions from different tissues were subjected to gel permeation chromatography on Sepharose 4B, with separation of polysaccharides with different degrees of polymerization, the highest molecular mass (above 2000 kDa) being found in young leaves. The molecular mass of the leaf blade polymers was similar (250 kDa) to that of maize coleoptile ß-glucan used for comparison. The 4 M KOH fraction injected into rats with streptozotocin-induced diabetes showed hypoglycemic activity, reducing blood sugar to normal levels for approximately 24 h. This performance was better than that obtained with pure ß-glucan from barley, which decreased blood sugar levels for about 4 h. These results suggest that the activity of ß-glucans from R. repens is responsible for the use of this plant extract as a hypoglycemic drug in folk medicine.
Resumo:
An assumption commonly made in the study of visual perception is that the lower the contrast threshold for a given stimulus, the more sensitive and selective will be the mechanism that processes it. On the basis of this consideration, we investigated contrast thresholds for two classes of stimuli: sine-wave gratings and radial frequency stimuli (i.e., j0 targets or stimuli modulated by spherical Bessel functions). Employing a suprathreshold summation method, we measured the selectivity of spatial and radial frequency filters using either sine-wave gratings or j0 target contrast profiles at either 1 or 4 cycles per degree of visual angle (cpd), as the test frequencies. Thus, in a forced-choice trial, observers chose between a background spatial (or radial) frequency alone and the given background stimulus plus the test frequency (1 or 4 cpd sine-wave grating or radial frequency). Contrary to our expectations, the results showed elevated thresholds (i.e., inhibition) for sine-wave gratings and decreased thresholds (i.e., summation) for radial frequencies when background and test frequencies were identical. This was true for both 1- and 4-cpd test frequencies. This finding suggests that sine-wave gratings and radial frequency stimuli are processed by different quasi-linear systems, one working at low luminance and contrast level (sine-wave gratings) and the other at high luminance and contrast levels (radial frequency stimuli). We think that this interpretation is consistent with distinct foveal only and foveal-parafoveal mechanisms involving striate and/or other higher visual areas (i.e., V2 and V4).
Resumo:
The aim of this study was to assess contrast sensitivity for angular frequency stimuli as well as for sine-wave gratings in adults under the effect of acute ingestion of alcohol. We measured the contrast sensitivity function (CSF) for gratings of 0.25, 1.25, 2.5, 4, 10, and 20 cycles per degree of visual angle (cpd) as well as for angular frequency stimuli of 1, 2, 4, 24, 48, and 96 cycles/360°. Twenty adults free of ocular diseases, with normal or corrected-to-normal visual acuity, and no history of alcoholism were enrolled in two experimental groups: 1) no alcohol intake (control group) and 2) alcohol ingestion (experimental group). The average concentration of alcohol in the experimental group was set to about 0.08%. We used a paradigm involving a forced-choice method. Maximum sensitivity to contrast for sine-wave gratings in the two groups occurred at 4 cpd sine-wave gratings and at 24 and 48 cycles/360° for angular frequency stimuli. Significant changes in contrast sensitivity were observed after alcohol intake compared with the control condition at spatial frequency of 4 cpd and 1, 24, and 48 cycles/360° for angular frequency stimuli. Alcohol intake seems to affect the processing of sine-wave gratings at maximum sensitivity and at the low and high frequency ends for angular frequency stimuli, both under photopic luminance conditions.
Resumo:
Some ophthalmic surgeries require induction of mydriasis, however, drugs traditionally used for this purpose significantly reduces tear production. To evaluate the effect of acepromazine and tramadol, used alone or in combination, on pupil diameter, tear production, heart and respiratory rate, systolic blood pressure and rectal temperature, these drugs were administered to seven clinically normal dogs divided into three experimental groups (G1 - acepromazine; G2 - tramadol; G3 - tramadol + acepromazine) that differed only in the sedation protocol. Parameters were measured in four experimental moments. Miosis occurred in G1, in addition to reduced tear production and respiratory rate. No significant changes were found in the parameters assessed in G2, whereas in G3, there was decrease in tear production of the right eye, decrease in the respiratory rate and rectal temperature. Tramadol proved to be a drug suitable for pre-anesthetic procedures that require the maintenance of pupil diameter and keeps the tear production within normal parameters. However, the use of acepromazine alone or in combination with tramadol requires protection of the patient's eye surface to prevent the occurrence of undesirable ophthalmic changes.
Resumo:
The simple eyes (ocelli) of recently emerged adult Triatoma infestans exhibit a narrow elongated "pupil", surrounded by a ring of brown-reddish pigment, the "iris". This pupil does not respond to changes in the illumination, but varies in size after the imaginal ecdysis. This change corresponds, internally, with the growth of the corneal lens and the associated retina up to an age of about 20 days. This has not been previously observed in an insect. The use of this characteristic for recognising young adults of this species is suggested.
Resumo:
Chromium(III) at the ng L-1 level was extracted using partially silylated MCM-41 modified by a tetraazamacrocyclic compound (TAMC) and determined by inductively coupled plasma optical emision spectrometry (ICP OES). The extraction time and efficiency, pH and flow rate, type and minimum amount of stripping acid, and break- through volume were investigated. The method's enrichment factor and detection limit are 300 and 45.5 pg mL-1, respectively. The maximum capacity of the 10 mg of modified silylated MCM-41 was found to be 400.5±4.7 µg for Cr(III). The method was applied to the determination of Cr(III) and Cr(VI) in the wastewater of the chromium electroplating industry and in environmental and biological samples (black tea, hot and black pepper).
Resumo:
According to the equivalent light hypothesis, molecular defects in the photoreceptor lead to a continuous activation of the photoreceptor cascade in a manner equivalent to real light. The consequences in diseases such as retinitis pigmentosa (RP) are as disruptive to the cells as real light. Two forms of the equivalent light hypothesis can be distinguished: strong - mutations in rhodopsin or other cascade proteins in some forms of RP continuously excite the visual phototransduction cascade; weak - disruption of outer segments in all patients with RP eliminates circulating dark current and blocks neurotransmitter release in a manner similar to real light. Both forms of the equivalent light hypothesis predict that pupils of patients with RP will be constricted like those of normal subjects in the light. The purpose of this study was to test the equivalent light hypothesis by determining whether steady-state pupil diameter following full dark adaptation is abnormally small in any of a sample of patients with RP. Thirty-five patients with RP and 15 normal subjects were tested. Direct steady-state pupillometric measures were obtained from one eye in a full-field dome after 45 min of dark adaptation by videotaping the pupil with an infrared camera. Mean pupil diameter in the dark was comparable (t = -0.15, P = 0.88) between patients with RP (6.85 ± 0.58 mm) and normal subjects (6.82 ± 0.76 mm). The results of the present study are clearly counter to the prediction of the second (weaker) form of the equivalent light hypothesis.
Resumo:
In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia) and higher order aberrations (coma, spherical aberration, etc.). We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS) sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE) of less than 0.1 µm for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5º for the axis. This precision is sufficient for customized corneal ablations, among other applications.