224 resultados para nuclear reaction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The surface of human syncytiotrophoblast does not induce maternal blood platelet aggregation even though it is not an endothelium. It can be surmised that as occurs in endothelial injury the subcellular components of the syncytiotrophoblast may have pro-or antiaggregatory activity. During congenital Chagas' disease which is associated to trophoblast lesions, platelets may play a role in the development of T. cruzi-induced placentitis. In the present work the aggregatory behaviour of normal human blood platelets was recorded after their challenging with subcellular fractions of syncytiotrophoblast isolated from normal and chagasic women. Nuclear, Mitochondrial, Microsomal and Supernatant fractions isolated from normal and chagasic syncytiotrophoblast failed to induce per se any aggregatory reaction on platelets. When samples of platelet-rich plasma (PRP) were preincubated with normal and chagasic nuclear fractions and then stimulated with collagen at threshold level (CT-PRP) an inhibition of the aggregatory response was observed. Treatment of CT-PRP with normal and chagasic mitochondrial fractions induced inhibition of platelet aggregation whereas only chagasic fraction reduced latency time. Microsornal fraction from normal placentas showed no significant effects on platelet aggregation. It is concluded that subcellular fractions of normal human syncytiotrophoblast do not exhibit any effect on platelet aggregation, whereas those subcellular fractions enriched in intracellular membrane components isolated from chagasic placentas inhibit platelet aggregation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detection of HBV-DNA by PCR was compared with other serological markers (HBsAg, HBeAg and anti-HBe) in a series of49 Chronic Hepatitis B patients, including 12 with a spontaneous clearance of HBsAg. None of these HBsAg negative cases were PCR positive, but 33/37 (89.2%) HBsAg positive cases were PCR positive (p < 0.0001). Among HBsAg positive samples, nine cases were HBeAg positive and anti-HBe negative, all of them PCR positive. Other 3 patients were HBeAg and anti-HBe positive and these cases were also found PCR positive. A third group included 21 patients anti-HBe positive and HBeAg negative: 19 of them were PCR positive and 2 were PCR negative. The last 4 cases were HBeAg and anti-HBe negative, two of them were PCR positive. The detection of anti-HBe viremic cases in the present series suggest that preC variants could occur in our country. In conclusion, the integrated phase o f chronic hepatitis B seems to be less frequent than it was assumed, when only HBeAg or dot blot hybridization techniques were used. The new term "low replication phase" might favorably replace the former "integrated phase".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A polymerase chain reaction was carried out to detect pathogenic leptospires isolated from animals and humans in Argentina. A double set of primers (G1/G2, B64-I/B64-II), described before, were used to amplify by PCR a DNA fragment from serogroups belonging to Leptospira interrogans but did not allow to detect saprophytic strains isolated from soil and water (L. biflexa). This fact represents an advantage since it makes possible the differentiation of pathogenic from non-pathogenic leptospires in cultures. The sensitivity of this assay has been determined, allowing to detect just only 10 leptospires in the reaction tube. Those sets of primers generated either a 285 bp or 360 bp fragment, depending on the pathogenic strain

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work was planned by taking into account all the knowledge accumulated from the immunological study of paracoccidioidomycosis. It aimed at comparing a polysaccharide antigen from Histoplasma capsulatum to a classic histoplasmin with the help of intradermal tests of delayed type of hypersensitivity. Tests were applied to 115 individuals in Santo Amaro, a town in the state of São Paulo. Positive results using classic histoplasmin were obtained in 46.0% cases whereas positive results using the polysaccharide antigen at its hightest concentration were obtained in 51.30% cases. The major conclusion in this investigation is that it is possible to use the polysaccharide antigen as histoplasmin instead of the filtrate antigen

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to determine the prevalence of certain mycoplasma species, i.e., Mycoplasma hominis, Ureaplasma urealyticum and Mycoplasma penetrans, in urethral swabs from HIV-1 infected patients compared to swabs from a control group. Mycoplasmas were detected by routine culture techniques and by the Polymerase Chain Reaction (PCR) technique, using 16SrRNA generic primers of conserved region and Mycoplasma penetrans specific primers. The positivity rates obtained with the two methods were comparable. Nevertheless, PCR was more sensitive, while the culture techniques allowed the quantification of the isolates. The results showed no significant difference (p < 0.05) in positivity rates between the methods used for mycoplasma detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening blood donations for anti-HCV antibodies and alanine aminotransferase (ALT) serum levels generally prevents the transmission of hepatitis C virus (HCV) by transfusion. The aim of the present study was to evaluate the efficiency of the enzyme immunoassay (EIA) screening policy in identifying potentially infectious blood donors capable to transmit hepatitis C through blood transfusion. We have used a reverse transcriptase (RT)-nested polymerase chain reaction (PCR) to investigate the presence of HCV-RNA in blood donors. The prevalence of HCV-RNA positive individuals was compared with the recombinant immunoblot assay (RIBA-2) results in order to assess the usefulness of both tests as confirmatory assays. Both tests results were also compared with the EIA-2 OD/C ratio (optical densities of the samples divided by the cut off value). ALT results were expressed as the ALT quotient (qALT), calculated dividing the ALT value of the samples by the maximum normal value (53UI/l) for the method. Donors (n=178) were divided into five groups according to their EIA anti-HCV status and qALT: group A (EIA > or = 3, ALT<1), group B (EIA > or = 3, ALT>1), group C (1<=EIA<3, ALT<1), group D (1<=EIA<3, ALT>1) and group E (EIA<=0.7). HCV sequences were detected by RT-nested PCR, using primers for the most conserved region of viral genome. RIBA-2 was applied to the same samples. In group A (n=6), all samples were positive by RT-nested PCR and RIBA-2. Among 124 samples in group B, 120 (96.8%) were RIBA-2 positive and 4 (3.2%) were RIBA-2 indeterminate but were seropositive for antigen c22.3. In group B, 109 (87.9%) of the RIBA-2 positive samples were also RT-nested PCR positive, as well as were all RIBA-2 indeterminate samples. In group C, all samples (n=9) were RT-nested PCR negative: 4 (44.4%) were also RIBA-2 negative, 4 (44.4%) were RIBA-2 positive and 1 (11.1%) was RIBA-2 indeterminate. HCV-RNA was detected by RT-nested PCR in 3 (37.5%) out of 8 samples in group D. Only one of them was also RIBA-2 positive, all the others were RIBA-2 indeterminate. All of the group E samples (controls) were RT- nested PCR and RIBA-2 negative. Our study suggests a strong relation between anti-HCV EIA-2 ratio > or = 3 and detectable HCV-RNA by RT-nested PCR. We have also noted that blood donors with RIBA-2 indeterminate presented a high degree of detectable HCV-RNA using RT-nested PCR (75%), especially when the c22.3 band was detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to determine Schistosoma mansoni infection rates in Biomphalaria tenagophila and B. straminea, low stringency polymerase chain reaction (LS-PCR) technique was used as a complementary method to light exposure technique. LS-PCR has already been standardized in our laboratory to detect the trematode DNA in B. glabrata. Higher S. mansoni infection rates were detected using conventional method and LS-PCR. The parasite DNA profile was detected in both species after 7-day exposure to miracidia, using LS-PCR. This technique enables early detection of schistosomiasis transmission focuses, in endemic areas, before the beginning of cercariae shedding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop a polymerase chain reaction (PCR) protocol for the detection of Salmonella in artificially contaminated chicken meat. Tests were performed with different dilutions of Salmonella Typhimurium or Salmonella Enteritidis cells (10-7, 10-8 or 10-9 CFU/mL) inoculated in chicken meat samples, in order to establish the limits of detection, incubation times (0, 6, 8 and 24 hours of pre-enrichment in PBW 1%) and three DNA extraction protocols (phenol-chloroform, thermal treatment and thermal treatment and Sephaglass). The assay was able to detect until 10-9 CFU/mL of initial dilution of Salmonella cells inoculated in chicken meat, which allows detection of Salmonella within 48 hours, including 24 hours of pre-enrichment and using the phenol-chloroform DNA extraction protocol. As the results are obtained in a shorter time period than that of microbiological culture, this procedure will be useful in the methodology for detection of Salmonella in chicken.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Brazil, the main etiologic agent of Leishmaniasis that frequently presents with mucosal involvement belongs to the Viannia subgenus. The therapeutic conduct in this disease depends on the parasitological diagnosis, and classical methods are restricted in identifying the agent. In this paper we describe a polymerase chain reaction (PCR), which uses primers designed from mini-exons repetitive sequences. The PCR amplifies a 177bp fragment that can distinguish (Viannia) from (Leishmania) subgenus. This test could be a useful diagnostic tool.