17 resultados para measuring bioimpedance
Resumo:
Measurement of telomerase activity in clinically obtained tumor samples may provide important information for use as both a diagnostic marker and a prognostic indicator for patient outcome. In order to evaluate telomerase activity in tumor tissue without radiolabeling the product, we developed a simple telomeric repeat amplification protocol-silver-staining assay that is less time-consuming, is safe and requires minimal equipment. In addition, we determined the sensitivity of the silver-staining method by using extracts of telomerase-positive thyroid carcinoma cell lines which were serially diluted from 5,000 to 10 cells. Telomerase activity was also assayed in 19 thyroid tumors, 2 normal controls and 27 bone marrow aspirates. The results indicate that the technique permits the detection of telomerase activity from 5000 to as few as 10 cells. We propose that it could be immediately applicable in many laboratories due to the minimal amount of equipment required.
Resumo:
In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia) and higher order aberrations (coma, spherical aberration, etc.). We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS) sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE) of less than 0.1 µm for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5º for the axis. This precision is sufficient for customized corneal ablations, among other applications.