58 resultados para intraocular prosthesis
Resumo:
Foi realizada pesquisa de anticorpos IgG, IgM e IgA anti-Toxoplasma gondii no soro e fluidos intra-oculares (humor aquoso e vítreo) de pacientes com toxoplasmose ocular. A partir dos resultados obtidos verificou-se que anticorpos IgG e IgA intraocular anti-Toxoplasma gondii podem vir a ser importantes marcadores no diagnóstico de toxoplasmose ocular.
Resumo:
In order to determine the prevalence of ocular lesions in HTLV-1 infected patients in Salvador Bahia, a transversal study was conducted on 140 HTLV-1 infected patients (90 asymptomatic and 50 tropical spastic paraparesis/HTLV-1-associated myelopathy) between June 2004 and November 2005. The ophthalmological examination included visual acuity measurement, ocular motility, biomicroscopy of the anterior and posterior chambers, intraocular pressure and evaluation of lachrymal secretion. Observation verified 4 (2.8%) out of 140 patients with uveitis (two patients had intermediate uveitis and two had pan-uveitis) and 39 (36.4%) out of 107 patients with keratoconjunctivitis sicca. The prevalence of Keratoconjunctivitis sicca was significantly higher among the TSP/HAM patients (OR age adjusted=3.64; 95%CI 1.59-8.32). Uveitis and corneal opacities were also important findings, indicating the strong need for periodic ophthalmological follow-up in all HTLV-1 subjects.
Resumo:
Aspergillosis is an infection caused by saprophytic fungi of the genus Aspergillus, which typically occurs in immunosuppressed individuals, but has also been reported in immunocompetent patients. The main routes of entry are the respiratory tract, skin, cornea, and ear, and the infection may be localized or disseminated by contiguity or vascular invasion. We report a severe case of rhinosinusitis with cutaneous involvement, caused by invasive aspergillosis, in an immunocompetent user of inhaled cocaine. Invasive aspergillosis related to cocaine abuse has not yet been reported in the literature. After itraconazole treatment and surgical debridement, complete clinical remission was achieved. Nasal reconstruction with a skin graft over a silicone prosthesis resulted in a satisfactory esthetic outcome.
Resumo:
We sought to describe the bone bridge technique in adults, and present a variation for use in children, as well as to present its applicability as an option in elective transtibial amputations. This paper presents a prospective study of 15 transtibial amputations performed between 1992 and 1995 in which the bone bridge technique was employed. The patients' ages ranged from 8 to 48 years, with an average of 22.5 years. This technique consisted of the preparation of a cylinder of periosteum extracted from the tibia and with cortical bone fragments attached to it to promote a tibiofibular synostosis on the distal extremity of the amputation stump. We noted that the cortical bone fragments were dispensable when the technique was employed in children, due to the increased osteogenic capacity of the periosteum. This led to a variation of the original technique, a bone bridge without the use of the cortical bone fragments. RESULTS: The average time spent with this procedure, without any significant variation between adults and children, was 171 minutes. The adaptation to the definitive prosthesis was accomplished between 20 and 576 days, with an average of 180 days. Revision of the procedure was necessary in 3 amputations. CONCLUSIONS: This technique may be employed in transtibial amputations in which the final length of the stump lies next to the musculotendinous transition of the gastrocnemius muscle, as well as in the revision of amputation stumps in children, where the procedure has been shown to be effective in the prevention of lesions due to excessive bone growth.
Resumo:
OBJECTIVE: The objective of this study is to evaluate the benefits of drainage in the Stoppa procedure for inguinal repair. PATIENTS AND METHODS: The use of a suction drain was randomized at the end of the surgical intervention in 26 male patients undergoing inguinal hernia repair, divided into 2 groups: Group A, 12 patients undergoing drainage, and group B, 14 patients not undergoing drainage. On the second postoperative day, all patients underwent abdominal pelvic computed tomography scan examination to detect the presence of abdominal fluid collection. RESULTS: In group A, no patient developed fluid collection in the preperitoneal space, and 1 patient presented with an abscess in the preperitoneal space on the 15th postoperative day. In group B, 12 patients presented with fluid collections in the preperitoneal space on computed tomography scan evaluation. However, only 3 patients presented minor complications. None of the patients developed a major complication. CONCLUSION: The use of suction drainage with the Stoppa procedure does not provide any benefit.
Resumo:
OBJECTIVE: To evaluate the early outcome of mitral valve prostheses implantation and left ventricular remodeling in 23 patients with end-stage cardiomyopathy and secondary mitral regurgitation (NYHA class III and IV). METHODS: Mitral valvular prosthesis implantation with preservation of papillary muscles and chordae tendinae, and plasty of anteriun cuspid for remodeling of the left ventricle. RESULTS: The surgery was performed in 23 patients, preoperative ejection fraction (echocardiography) varied from 13% to 44% (median: 30%). In 13 patients associated procedures were performed: myocardial revascularization (9), left ventricle plicature repair (3) and aortic prosthese implantation (1). Early deaths (2) occurred on the 4th PO day (cardiogenic shock) and on the 20th PO day (upper gastrointestinal bleeding), and a late death in the second month PO (ventricular arrhythmia). Improvement occurred in NYHA class in 82.6% of the patients (P<0.0001), with a survival rate of 86.9% (mean of 8.9 months of follow-up). CONCLUSION: This technique offers a promising therapeutic alternative for the treatment of patients in refractory heart failure with cardiomyopathy and secondary mitral regurgitation.
Resumo:
OBJECTIVE: To describe a surgical procedure utilizing a malleable bovine pericardium ring in mitral valve repair and clinical and echodopplercadiographic results. METHODS: Thirty-two (25 female and 7 male) patients, aged between 9 and 66 (M=36.4±17.2) years, were studied over a 16-month period, with 100% follow-up. In 23 (72%) of the patients, the mitral approach was the only one applied; 9 patients underwent associated operations. The technique applied consisted of measuring the perimeter of the anterior leaflet and implanting, according to this measurement, a flexible bovine pericardium prosthesis for reinforcement and conformation of the posterior mitral annulus, reducing it to the perimeter of the anterior leaflet with adjustment of the valve apparatus. RESULTS: The patient survival ratio was 93.8%, with 2 (6.2%) fatal outcomes, one from unknown causes, the other due to left ventricular failure. Only one reoperation was performed. On echodopplercardiography, 88% of the patients had functional recovery of the mitral valve (50% without and 38% with mild insufficiency and no hemodynamic repercussions). Of four (12%) of the remaining patients, 6% had moderate and 6% had seigre insufficiency. Twenty-eight percent of class II patients and 72% of class III patients passed into classes I (65%), II (32%), and III (3%), according to NYHA classification criteria. CONCLUSION: Being flexible, the bovine pericardium ring fit perfectly into the valve annulus, taking into account its geometry and contractility. Valve repair was shown to be reproducible, demonstrating significant advantages during patient evolution, which did not require anticoagulation measures.
Resumo:
OBJECTIVE: Our aim was to compare, in a non randomized study, the surgical outcome in elderly patients with mechanical (Group 1; n=83) and bioprosthetic valve implants (Group 2; n=136). METHODS: During a three year period, 219 patients >75 years underwent Aortic Valve Replacement. The groups matched according to age, sex, comorbidity, valve pathology and concomitant Coronary Artery Bypass Surgery. Follow-up was a total of 469 patient-years (mean follow-up 2.1 years, maximum 4,4 years). RESULTS: Operative mortality was zero and the overall early mortality was 2.3 % (within 30 days). Actuarial survival was 87.5 ± 4.0% and 66.1 ± 7.7% (NS) at 4 years in Group 1 and Group 2, respectively. Freedom from valve-related death was 88.9 ± 3.8% in Group 1 and 69.9±7.9% (NS) in Group 2 at 4 years. CONCLUSION: Aortic Valve Replacement in the elderly (>75 years) is a safe procedure even in cases where concomitant coronary artery revascularization is performed. Only a few anticoagulant-related complications were reported and this may indicate that selected groups of elderly patients with significant life expectancy may benefit from mechanical implants .
Resumo:
OBJECTIVE: This study evaluated the effects of a new method of mitral valve replacement on left ventricular (LV) remodeling and heart failure functional class. METHODS: Eight patients (6 men) with severe mitral regurgitation from end-stage dilated cardiomyopathy underwent surgery. Five patients were in functional class (FC) IV, 2 were in FC III and 1 was in FC III/IV. Age ranged from 33 to 63 years. Both the anterior and posterior leaflets of the mitral valve were divided into hemileaflets. The resultant 4 pedicles were displaced under traction toward the left atrium and anchored between the mitral annulus and an implanted valvular prosthesis. The beating heart facilitated ideal chordae tendineae positioning. RESULTS: All patients survived and were discharged from the hospital. After a mean follow-up period of 6.5 months (1-12 m), 5 patients were in FC I; 2 in FC I/II; and 1 in FC II. The preoperative ejection fraction ranged from 19% to 30% (mean: 25.7±3.4 %), and the postoperative ejection fraction ranged from 21% to 40% (mean: 31.1± 5.8%). Doppler echocardiography showed evidence of LV remodeling in 4 patients, including lateral wall changes and a tendency of the LV cavity to return to its elliptical shape. CONCLUSION: This technique of mitral valve replacement, involving new positioning of the chordae tendineae, allowed LV remodeling and improvement in FC during this brief follow-up period.
Resumo:
OBJECTIVE: To assess the occurrence of late thromboembolism after surgical repair of chronic atrial fibrillation (AF) simultaneously with repair of mitral valve using the Cox-Maze procedure. METHODS: 69 patients underwent Cox 3 procedure, with no cryoablation simultaneously with mitral valvuloplasty or prosthesis. Mean age was 49.9±13.2 years. Mean follow-up was of 31.7±19 months. Types of lesion were as follows: 33 (48%) stenoses, 23 (33%) insufficiencies, and 13 (19%) double lesions. Procedures were: 64 (93%) valvuloplasties, 3 (4%) biological and 2 (3%) mechanical prosthesis placement. There were 9 (13%) patients with previous systemic embolism and 2 (3%) had left atrial thrombi. RESULTS: Early mortality was 7% and late 1%. 2 patients (3%) were reoperated for mitral placement. At last evaluation, 10 patients (15%), were in AF. The remaining 59 (85%) were either in sinus / atrial rythm (74%) or under pacing (12%). There were no occurrence of early or late, systemic or pulmonary embolism. Permanent anticoagulation was employed in 16 cases, 10 in regular rythm and 6 in AF. The remaining 47 (75%), 2 in AF and 45 in regular rythm, did not receive anticoagulants. CONCLUSIONS: These results are in accordance with others series, where the occurrence of embolism was rare after maze procedure. Permanent systemic anticoagulation seems to be unnecessary in those cases.
Resumo:
We report the case of implantation of metallic mitral and aortic valve prostheses 6 months earlier, with subsequent multiple embolic episodes. The anatomicopathological examination of the thrombus of the third embolic episode was compatible with Aspergillus sp, which was treated with amphotericin B, followed by oral itraconazole. On the fourth embolism, vegetations were visualized in the ascending aorta on echocardiography and resonance imaging, and the patient underwent replacement of the aortic segment by a Haemashield tube and exploration of the aortic prosthesis, which was preserved, because no signs of endocarditis were found. Four months later, the patient died due to cardiogenic shock secondary to acute myocardial infarction caused by probable coronary embolism and partial dysfunction of the aortic prosthesis.
Resumo:
Background: Conventional surgical repair of thoracic aortic dissections is a challenge due to mortality and morbidity risks. Objectives: We analyzed our experience in hybrid aortic arch repair for complex dissections of the aortic arch. Methods: Between 2009 and 2013, 18 patients (the mean age of 67 ± 8 years-old) underwent hybrid aortic arch repair. The procedural strategy was determined on the individual patient. Results: Thirteen patients had type I repair using trifurcation and another patient with bifurcation graft. Two patients had type II repair with replacement of the ascending aorta. Two patients received extra-anatomic bypass grafting to left carotid artery allowing covering of zone 1. Stent graft deployment rate was 100%. No patients experienced stroke. One patient with total debranching of the aortic arch following an acute dissection of the proximal arch expired 3 months after TEVAR due to heart failure. There were no early to midterm endoleaks. The median follow-up was 20 ± 8 months with patency rate of 100%. Conclusion: Various debranching solutions for different complex scenarios of the aortic arch serve as less invasive procedures than conventional open surgery enabling safe and effective treatment of this highly selected subgroup of patients with complex aortic pathologies.
Resumo:
Background:The ACUITY and CRUSADE scores are validated models for prediction of major bleeding events in acute coronary syndrome (ACS). However, the comparative performances of these scores are not known.Objective:To compare the accuracy of ACUITY and CRUSADE in predicting major bleeding events during ACS.Methods:This study included 519 patients consecutively admitted for unstable angina, non-ST-elevation or ST-elevation myocardial infarction. The scores were calculated based on admission data. We considered major bleeding events during hospitalization and not related to cardiac surgery, according to the Bleeding Academic Research Consortium (BARC) criteria (type 3 or 5: hemodynamic instability, need for transfusion, drop in hemoglobin ≥ 3 g, and intracranial, intraocular or fatal bleeding).Results:Major bleeding was observed in 31 patients (23 caused by femoral puncture, 5 digestive, 3 in other sites), an incidence of 6%. While both scores were associated with bleeding, ACUITY demonstrated better C-statistics (0.73, 95% CI = 0.63 - 0.82) as compared with CRUSADE (0.62, 95% CI = 0.53 - 0.71; p = 0.04). The best performance of ACUITY was also reflected by a net reclassification improvement of + 0.19 (p = 0.02) over CRUSADE’s definition of low or high risk. Exploratory analysis suggested that the presence of the variables ‘age’ and ‘type of ACS’ in ACUITY was the main reason for its superiority.Conclusion:The ACUITY Score is a better predictor of major bleeding when compared with the CRUSADE Score in patients hospitalized for ACS.