40 resultados para fracture repair


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The freeze-fracture technique was used to analyse the organization of the plasma membrane, as well as membranes of cytoplasmic organelles, of the pathogenic protozoan Trichomonas vaginalis. Rosettes formed by 4 to 14 intramembranous particles were seen on the fracture faces of the membrane lining the anterior flagella as well as in fracture faces of the plasma membrane enclosing the anterior region of the protozoan and in cytoplasmic organelles. Special organization of the membrane particles were also seen in the region of association of the recurrent flagellum to the cell body.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The process of repairing intestinal vascular lesions induced by schistosomiasis in mice was studied before and after curative chemotherapy, by means of histopathology coupled with injections of the mesenteric veins with India ink or plastic, in this case followed by corrosion in strong acid. The granulomas were avascular, mainly formed while within blood vessels, and were associated with distortion of the intestinal vasculature in their proximity, represented by tortuosities, focal dilatation, narrowing, and anastomosis of the mucosal and submucosal veins. Two to four months after cure of schistosomiasis involuting granulomas were seen to be slowly vascularized, a process going from the periphery toward the center of the granulomas. No intravascular granulomas were seen four months after treatment. The previously distorted mucosal and submucosal veins gradually regained their normal appearance, only a slight tortuosity remaining.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traunatic perineal hernia remains a rare clinical entity despite an overall increase in blunt trauma. Because of the incidence of other associated injuries, the mortality is high. Most of the perineal defects are repaired during the orthopaedics surgery to reconstitute the pelvis and few patients develop a true perineal hernia without pelvic instability. A 80-year-old woman was involved in a running over accident with disjunction of pubic symphysis, dislocation of sacrum-iliac junction and fracture of pubis and ischium. The patient was submitted to an orthopaedic surgery and latter development an perineal hernia through the genitalia. The diagnosis could be established with physical examination alone. Conventional radiology, computadorized tomography, and ultrasound should also be done to progran the surgery. The repair approach was performed using a marlex mesh, fixed in the pelvic bones, Cooper ligament, and the abdominal wall. The mesh was stood in a retro- peritoneal position, rebuilding the pelvic floor without reconstruction the pelvic bones. We conclude that this is an efficient approach to repair of traumatic postoperative perineal hernia, mainly in patients with high operative risk, when the osseous repair is not necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We reported a case of a twenty-nine-year-old male who presented a penile fracture associated with urethral injury caused by a sexual intercourse. An ideal anamnesis and a special physical examination were determinant to correct diagnostics. Ultrasonography and uretrocistography must be performed for confirmation. The treatment is based on the presence of associated urethral injury. The surgical repair of cavernous body and urethra can produce good results, with a favorable prognosis and minimal rate of complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the effectiveness and safety of correction of pectus excavatum by the Nuss technique based on the available scientific evidence.Methods: We conducted an evidence synthesis following systematic processes of search, selection, extraction and critical appraisal. Outcomes were classified by importance and had their quality assessed by the Grading of Recommendations Assessment, Development and Evaluation (GRADE).Results: The process of selection of items led to the inclusion of only one systematic review, which synthesized the results of nine observational studies comparing the Nuss and Ravitch procedures. The evidence found was rated as poor and very poor quality. The Nuss procedure has increased the incidence of hemothorax (RR = 5.15; 95% CI: 1.07; 24.89), pneumothorax (RR = 5.26; 95% CI: 1.55; 17.92) and the need for reintervention (RR = 4.88; 95% CI: 2.41; 9.88) when compared to the Ravitch. There was no statistical difference between the two procedures in outcomes: general complications, blood transfusion, hospital stay and time to ambulation. The Nuss operation was faster than the Ravitch (mean difference [MD] = -69.94 minutes, 95% CI: -139.04, -0.83).Conclusion: In the absence of well-designed prospective studies to clarify the evidence, especially in terms of aesthetics and quality of life, surgical indication should be individualized and the choice of the technique based on patient preference and experience of the team.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: to evaluate the efficacy of endovascular repair of popliteal artery aneurysms on maintaining patency of the stent in the short and medium term. METHODS: this was a retrospective, descriptive and analytical study, conducted at the Integrated Vascular Surgery Service at the Hospital da Beneficência Portuguesa de São Paulo. We followed-up 15 patients with popliteal aneurysm, totaling 18 limbs, treated with stent from May 2008 to December 2012. RESULTS: the mean follow-up was 14.8 months. During this period, 61.1% of the stents were patent. The average aneurysm diameter was 2.5cm, ranging from 1.1 to 4.5cm. The average length was 5cm, ranging from 1.5 to 10 cm. In eight cases (47.1%), the lesion crossed the joint line, and in four of these occlusion of the prosthesis occurred. In 66.7% of cases, treatment was elective and only 33.3% were symptomatic patients treated on an emergency basis. The stents used were Viabahn (Gore) in 12 cases (66.7%), Fluency (Bard) in three cases (16.7%), Multilayer (Cardiatis) in two cases (11.1%) and Hemobahn (Gore) in one case (5.6%). In three cases, there was early occlusion (16.6%). During follow-up, 88.2% of patients maintained antiplatelet therapy. There was no leakage at ultrasound (endoleak). No fracture was observed in the stents. CONCLUSION: the results of this study are similar to other published series. Probably, with the development of new devices that support the mechanical characteristics found on the thighs, there will be improved performance and prognosis of endovascular restoration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antiandrogenic therapy (ADT) for prostate cancer represents an additional risk factor for the development of osteoporosis and fragility fractures. Still, bone health of patients on ADT is often not evaluated. After literature research we found that simple preventive measures can prevent bone loss in these patients, resulting in more cost-effective solutions to the public health system and family when compared to the treatment of fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present paper is to study the relationship between the fracture modes in hydrogen-assisted cracking (HAC) in microalloied steel and the emission of acoustic signals during the fracturing process. For this reason, a flux-cored arc weld (FCAW) was used in a high-strength low-alloy steel. The consumable used were the commercially available AWS E120T5-K4 and had a diameter of 1.6 mm. Two different shielding gases were used (CO2 and CO2+5% H2) to obtain complete phenomenon characterization. The implant test was applied with three levels of restriction stresses. An acoustic emission measurement system (AEMS) was coupled to the implant test apparatus. The output signal from the acoustic emission sensor was passed through an electronic amplifier and processed by a root mean square (RMS) voltage converter. Fracture surfaces were examined by scanning electron microscopy (SEM) and image analysis. Fracture modes were related with the intensity, the energy and the number of the peaks of the acoustic emission signal. The shielding gas CO2+5% H2 proved to be very useful in the experiments. Basically, three different fracture modes were identified in terms of fracture appearance: microvoid coalescence (MVC), intergranular (IG) and quasi-cleavage (QC). The results show that each mode of fracture presents a characteristic acoustic signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper draws on the basic problems related to the determination of parameters to characterize the structural behavior of concretes using Fracture Mechanics concepts. Experimental procedures and results are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crack formation and growth in steel bridge structural elements may be due to loading oscillations. The welded elements are liable to internal discontinuities along welded joints and sensible to stress variations. The evaluation of the remaining life of a bridge is needed to make cost-effective decisions regarding inspection, repair, rehabilitation, and replacement. A steel beam model has been proposed to simulate crack openings due to cyclic loads. Two possible alternatives have been considered to model crack propagation, which the initial phase is based on the linear fracture mechanics. Then, the model is extended to take into account the elastoplastic fracture mechanic concepts. The natural frequency changes are directly related to moment of inertia variation and consequently to a reduction in the flexural stiffness of a steel beam. Thus, it is possible to adopt a nondestructive technique during steel bridge inspection to quantify the structure eigenvalue variation that will be used to localize the grown fracture. A damage detection algorithm is developed for the proposed model and the numerical results are compared with the solutions achieved by using another well know computer code.