19 resultados para flow field
Resumo:
E. coli was submitted to a 5G electromagnetic field generated by a alternate 60 Hz voltage source. The differences on growth and glucose consume in control and exposed groups were evaluated using the non-parametric Mann-Whitney U-test. There was a significant difference in glucose consume and growth in E. coli after 8 hours of exposition to electromagnetic field. It can be concluded that electromagnetic field had a positive effect in consume of glucose and growth of E. coli. The cause of these results can be explained by an increasing of glucose entrance through membrane due to the stimulated transport system via Facility Diffusion or cyclotron resonance. The growth can be caused by shortening of lag phase and excitement of log phase.
Resumo:
This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.
Resumo:
Persistence of Bacillus thuringiensis var. israelensis (Vectobac WDG) and methoprene (Metoprag S-2G) was evaluated against Aedes aegypti late third instar larvae of the Rockefeller strain in a semi-field bioassay. Tests were performed in Rio de Janeiro, using containers made of plastic, iron, concrete and asbestos, placed in a shaded area. The formulations used were 0.2 g of Vectobac-WDG and 1g of Metoprag S-2G per 100 liters of water in house storage containers. Vectobac WDG was tested twice, in March and in April/May, 2002. In March (temperature ranging from 21.5 to 39.3 ºC), 70-100% mortality was observed by the 7th day and declined abruptly thereafter. No significant differences were observed among the container types. In April/May (18.6 to 34.8 ºC) mortality was higher than 70% to 30-36 days in all cases, except in the iron container (40% mortality on the 12th day). Metoprag S-2G was evaluated in April/May, 2002, and induced mortality higher than 70% up to 15 days in the plastic and iron containers and only seven days in the concrete container. In the asbestos container, maximal mortality was achieved on day one post-treatment (66%). Our results point to a low persistence of both formulations in the weather conditions of Rio de Janeiro.