23 resultados para Wire-on-tube condenser
Resumo:
A morphological study was done on A. nigricans, based on the observation of shell, radula, renal region and genitalia of 50 specimens measuring 18 mm in diameter. The data obtained are to be compared with those recorded in our previous paper (PARAENSE & DESLANDES, 1955) on A. glabratus. The characteristics common to both species will not be mentioned here. The numerals refere to the means and their standard deviations: no special reference being done, they correspond to length measurementes. Shell - 18 mm in diameter, 6.37 ± 0.29 mm in greatest width, 6 whorls. Prevailing colur ferruginous sepia, a minority of olivaceous, ochreous, nigrescent and deeply black specimens being found. Right side variously depressed, umbilicated, 1.5 to 3.5 mm deep from the bottom of the umblicus to the highest level of the last whorl. Left side more depressed than the right one, broadly concave, 1.5 to 3.5 mm deep. Both sides show a varously distinct keel, that looks sharper at the left. Aperture deltoid, varying in outline and width. Body, extended - 60.26 ± 3.62 mm, less pigmented than in glabratus. Renal tube - 30.68 ± 1.69 mm, showing neither ridge nor pigmented line along its ventral surface, this negative character affording a sure means of separation from glabratus. Ovotestis - 14.48 ± 1.93 mm. Ovisperm duct - 13.04 ± 1.60 mm, including the non-unwound seminal vesicle. The latter was 0.97 ± 0,21 mm in greatest width. Carrefour - Resembling that of glabratus. Sperm duct - 21.36 ± 1.53 mm. Prostate - Prostate duct 7.14 ± 0.74 mm, collecting a row of long diverticula numbering 19.6 ± 3.1 and more separate than in glabratus. Last diverticulum generally bifurcate or arborescent, the remaining ones arborescent. Vas deferens - 28.68 ± 1.38. Ratio vas deferens/vergic sac = 6.8±0.8. Verge - 3.08 ± 0.28 mm long, 0.11 ± 0.02 mm wide. Vergic sac - 3.07 ± 0.28 mm long, about 0.20 mm wide. Ratio vergic sac/preputium = 0.84 ± 0.12. Preputium - 3.69 ± 0.47 mm long, 0.85 ± 0.10 mm wide. Albumen gland - Resembling taht of glabratus. Oviduct - 16.26 ± 1.41 mm, swollen at the cephalic end. Uterus - 13.24 ± 1.19 mm. Vagina - 1.70 ± 0.22 mm, swolen at the caudal portion. Spermatheca - 2.78 ± 0.40 mm long, 0.86 ± 0.16 mm wide. Spermathecal duct 1.11 ± 0.20 mm. Radula - 125 to 168 horizontal rows of teeth (mean 153.9 ± 8.4). Radula formula 28-1-28 to 36-1-36 (mean 31.8 ± 1.9). Mode formula 31-1-31. The morphological characteristics of the renal region and shell, and the great body length in the same condition of shell diameter, distinguish A. nigricans from the most related species A. glabratus, giving support to considering it a good species from a txonomic or phenotypic standpoint (morphospecies).
Resumo:
A cohort of 123 adult contacts was followed for 18‐24 months (86 completed the follow-up) to compare conversion and reversion rates based on two serial measures of QuantiFERON (QFT) and tuberculin skin test (TST) (PPD from TUBERSOL, Aventis Pasteur, Canada) for diagnosing latent tuberculosis (TB) in household contacts of TB patients using conventional (C) and borderline zone (BZ) definitions. Questionnaires were used to obtain information regarding TB exposure, TB risk factors and socio-demographic data. QFT (IU/mL) conversion was defined as <0.35 to ≥0.35 (C) or <0.35 to >0.70 (BZ) and reversion was defined as ≥0.35 to <0.35 (C) or ≥0.35 to <0.20 (BZ); TST (mm) conversion was defined as <5 to ≥5 (C) or <5 to >10 (BZ) and reversion was defined as ≥5 to <5 (C). The QFT conversion and reversion rates were 10.5% and 7% with C and 8.1% and 4.7% with the BZ definitions, respectively. The TST rates were higher compared with QFT, especially with the C definitions (conversion 23.3%, reversion 9.3%). The QFT conversion and reversion rates were higher for TST ≥5; for TST, both rates were lower for QFT <0.35. No risk factors were associated with the probability of converting or reverting. The inconsistency and apparent randomness of serial testing is confusing and adds to the limitations of these tests and definitions to follow-up close TB contacts.
Resumo:
In Brazil, pear production presents the same incipient situation over the last 15 years, due mostly to low production technology. In this context, this study aimed to evaluate the development, growth and production of the pear tree cultivars Cascatense, Tenra and Hosui grafted on 'CPP' quince rootstock, using 'FT' pear as interstem. This trial was carried out in Guarapuava, State of Paraná, Southern region of Brazil, by five productive cycles. The pear trees were planted in September of 2004, spaced at 1.0 x 4.0 m (2,500 trees ha-1), trained to the modified central leader, on a Four-wire trellis, with drip irrigation and cultivated under organic production system. The following variables were evaluated: sprouting, anthesis, yield, fruit weight, soluble solids content, titratable acidity, pulp firmness, canopy area per plant and per hectare and trunk diameter. The pear tree cv. Tenra was outstanding most of the years for fruit yield, and, consequently, showed the highest accumulated yield over the period (51.6 t ha-1), followed by the cultivars Cascatense (39.7 t ha-1) and Hosui (18.7 t ha-1). All pear cultivars presented suitable physical-chemical characteristics for commercial purposes, with minimal average soluble solids content of 11% at harvest. The maximum canopy area per hectare was attained for cv. Cascatense (3063.2 m²), that was considered insufficient for a high yield. These results suggest the needs for studies with higher density planting and other training systems, searching optimize canopy volume. One of the most limiting factors in the organic pear orchard was the incidence of pear dieback caused by Botriosphaeria dothidea, severe more often in pear trees cv. Hosui.
Resumo:
The construction and analytical evaluation of a coated graphite Al(III) ion-selective electrode, based on the ionic pair formed between the Al(F)n3-n anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated on a poly(vinylchloride) (PVC) matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh) in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter) attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m) of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m) of DBPh and 15% (m/m) of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III) ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane). The slope indicates that the ion-selective electrode responds preferentially to the Al(F)4- species. Application of this electrode for the aluminium(III) determination in stomach anti-acid samples is reported.
Resumo:
The objective of this work was to optimize the parameter setup for GTAW of aluminum using an AC rectangular wave output and continuous feeding. A series of welds was carried-out in an industrial joint, with variation of the negative and positive current amplitude, the negative and positive duration time, the travel speed and the feeding speed. Another series was carried out to investigate the isolate effect of the negative duration time and travel speed. Bead geometry aspects were assessed, such as reinforcement, penetration, incomplete fusion and joint wall bridging. The results showed that currents at both polarities are remarkably more significant than the respective duration times. It was also shown that there is a straight relationship between welding speed and feeding speed and this relationship must be followed for obtaining sound beads. A very short positive duration time is enough for arc stability achievement and when the negative duration time is longer than 5 ms its effect on geometry appears. The possibility of optimizing the parameter selection, despite the high inter-correlation amongst them, was demonstrate through a computer program. An approach to reduce the number of variables in this process is also presented.
Resumo:
The purpose of the present paper is to review work that has been done on the pulsed wire anemometer technique and also suggest further developments that could be made in its range of application. The aper discusses the three types of probes that have been used in pulsed wire anemometry: the crossed wire velocity probe, the parallel wire wall shear stress probe and the parallel wire velocity probe. The work shows that the crossed wire and the parallel wire techniques can be used to make velocity, turbulence and wall shear stress measurements in highly turbulent flows without any upper restriction on turbulence level. Comments are also made on the potential of a parallel wire probe for use in highly turbulent flows that would enable higher order velocity cross-product terms to be measured.
Resumo:
The application of flux cored arc welding (FCAW) has increased in manufacturing and fabrication. Even though FCAW is well known for its good capability in producing quality welds, few reports have been published on the cause of the relatively high diffusible hydrogen content in the weld metal and its relation with the ingredients used in the wire production and with the welding parameters (mainly welding current). This paper describes experiments where data obtained from weld metal diffusible hydrogen analysis, metal droplet collection, and high-speed recording of metal droplet transfer were used to evaluate the effect of welding current on diffusible hydrogen content in the weld metal. The results from gas chromatography analysis showed that weld metal hydrogen content indeed increased with welding current. A polynomial regressional analysis concluded that hydrogen increase with current was better described by a linear function with proportional constant of approximately 0.7 or 70%. Different from the GMA welding transfer behavior, statistical analysis showed only a small increase in metal droplet size with increasing current. The metal transfer mode remained in the globular range for currents between 100 and 150 A. The most surprising findings were with the high-speed cinematography recording. Observing the high speed movies, it was possible to see that at low current, "unmelted" flux sporadically touched the weld pool but at higher current, the flux remained touching the weld pool during the whole time of droplet formation and transfer. It is believed that since the flux has ingredients that contain hydrogen, hydrogen passes through the arc undisturbed, going to the weld bead intact and increasing the hydrogen content in the weld metal. Another important observation is regarding to droplet size. Droplet size increased with increasing current because forces from decomposed gases from the flux could sustain the droplets, retarding their transfer and allowing them to grow.
Resumo:
The neuroendocrine system regulates several organic functions such as reproduction, metabolism and adaptation to the environment. This system shows seasonal changes linked to the environment. The experimental model used in the present study was Lagostomus maximus maximus (viscacha). The reproduction of males of this species is photoperiod dependent. Twenty-four adult male viscachas were captured in their habitat at different times during one year. The adrenal glands were processed for light microscopy. Serial cuts were stained with hematoxylin-eosin for the morphometric study, and 100 nuclei of each zone of the adrenal cortex were counted per animal. Data were analyzed statistically by ANOVA and the Tukey test. The cells of the glomerulosa zone are arranged in a tube-shaped structure. The fasciculata zone has large cells with central nuclei and clearly visible nucleoli and with a vacuolar cytoplasm. In the reticularis zone there are two of types of cells, one with a nucleus of fine chromatin and a clearly visible nucleolus and the other with nuclear pycnosis. Morphometric analysis showed maximum nuclear volumes during the February-March period with values of 133 ± 7.3 µm3 for the glomerulosa, 286.4 ± 14.72 µm3 for the fasciculata, and 126.3 ± 9.49 µm3 for the reticularis. Minimum nuclear volumes were observed in August with values of 88.24 ± 9.9 µm3 for the glomerulosa, 163.7 ± 7.78 µm3 for the fasciculata and 64.58 ± 4.53 µm3 for the reticularis. The short winter photoperiod to which viscacha is subjected could inhibit the adrenal cortex through a melatonin increase which reduces the nuclear volume as well as the cellular activity.