23 resultados para Vehicle Emission Standards.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an increasing demand for detailed maps that represent in a simplified way the knowledge of the variability of a particular area or region maps. The objective was to outline precision boundaries among areas with different accuracy variability standards using magnetic susceptibility and geomorphic surfaces. The study was conducted in an area of 110 ha, which identified three compartment landscapes based on the geomorphic surfaces model. To determinate pH, organic matter, phosphorus, potassium and magnesium, the total sand and clay, 514 soil samples were collected at depths of 0-0.20 m and 0.60-0.80 m. The sum of base, cationic exchange capacity and base saturation were calculated and the magnetic susceptibility was evaluated in the laboratory using a system based on a balance of analytical precision method. Geomorphic surfaces identification allowed setting specific management areas (locations with maximum homogeneity of soil attributes). The map of spatial variability of magnetic susceptibility can be used to validate the precise boundaries among geomorphic surfaces identified in the field and infer the variability of clay content and soil base saturation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present paper is to study the relationship between the fracture modes in hydrogen-assisted cracking (HAC) in microalloied steel and the emission of acoustic signals during the fracturing process. For this reason, a flux-cored arc weld (FCAW) was used in a high-strength low-alloy steel. The consumable used were the commercially available AWS E120T5-K4 and had a diameter of 1.6 mm. Two different shielding gases were used (CO2 and CO2+5% H2) to obtain complete phenomenon characterization. The implant test was applied with three levels of restriction stresses. An acoustic emission measurement system (AEMS) was coupled to the implant test apparatus. The output signal from the acoustic emission sensor was passed through an electronic amplifier and processed by a root mean square (RMS) voltage converter. Fracture surfaces were examined by scanning electron microscopy (SEM) and image analysis. Fracture modes were related with the intensity, the energy and the number of the peaks of the acoustic emission signal. The shielding gas CO2+5% H2 proved to be very useful in the experiments. Basically, three different fracture modes were identified in terms of fracture appearance: microvoid coalescence (MVC), intergranular (IG) and quasi-cleavage (QC). The results show that each mode of fracture presents a characteristic acoustic signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing complexity of controller systems, applied in modern passenger cars, requires adequate simulation tools. The toolset FASIM_C++, described in the following, uses complex vehicle models in three-dimensional vehicle dynamics simulation. The structure of the implemented dynamic models and the generation of the equations of motion applying the method of kinematic differentials is explained briefly. After a short introduction in methods of event handling, several vehicle models and applications like controller development, roll-over simulation and real-time-simulation are explained. Finally some simulation results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the behavioral effects of different vehicles microinjected into the dorsal periaqueductal grey (DPAG) of male Wistar rats, weighing 200-250 g, tested in the elevated plus maze, animals were implanted with cannulas aimed at this structure. One week after surgery the animals received microinjections into the DPAG of 0.9% (w/v) saline, 10% (v/v) dimethyl sulfoxide (DMSO), 2% (v/v) Tween-80, 10% (v/v) propylene glycol, or synthetic cerebrospinal fluid (CSF). Ten min after the injection (0.5 &micro;l) the animals (N = 8-13/group) were submitted to the elevated plus maze test. DMSO significantly increased the number of entries into both the open and enclosed arms when compared to 0.9% saline (2.7 &plusmn; 0.8 and 8.7 &plusmn; 1.3 vs 0.8 &plusmn; 0.3 and 5.1 &plusmn; 0.9, respectively, Duncan test, P<0.05), and tended to increase enclosed arm entries as compared to 2% Tween-80 (8.7 &plusmn; 1.3 vs 5.7 &plusmn; 0.9, Duncan test, P<0.10). In a second experiment no difference in plus maze exploration was found between 0.9% saline- or sham-injected animals (N = 11-13/group). These results indicate that intra-DPAG injection of some commonly used vehicles such as DMSO, saline or Tween-80 affects the exploratory activity of rats exposed to the elevated plus maze in statistically different manners

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to identify the single photon emission computed tomography (SPECT) and magnetic resonance (MR) findings in juvenile systemic lupus erythematosus (JSLE) patients with CNS involvement and to try to correlate them with neurological clinical history data and neurological clinical examination. Nineteen patients with JSLE (16 girls and 3 boys, mean age at onset 9.2 years) were submitted to neurological examination, electroencephalography, cerebrospinal fluid analysis, SPECT and MR. All the evaluations were made separately within a period of 15 days. SPECT and MR findings were analyzed independently by two radiologists. Electroencephalography and cerebrospinal fluid analysis revealed no relevant alterations. Ten of 19 patients (53%) presented neurological abnormalities including present or past neurological clinical history (8/19, 42%), abnormal neurological clinical examination (5/19, 26%), and abnormal SPECT or MR (8/19, 42% and 3/19, 16%, respectively). The most common changes in SPECT were cerebral hypoperfusion and heterogeneous distribution of blood flow. The most common abnormalities in MR were leukomalacia and diffuse alterations of white matter. There was a correlation between SPECT and MR (P<0.05). We conclude that SPECT and MR are complementary and useful exams in the evaluation of neurological involvement of lupus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Head dipping (HD) is a behavioral pattern considered to have a risk assessment or an exploratory role and is used as a complementary parameter to evaluate anxiety in experimental animals. Since rats with electrolytic lesion in the area of the median raphe nucleus displayed high frequencies of HD in a previous study, the present investigation was undertaken to confirm this observation and to determine its anxiety-related origin. HD episodes were counted in adult male Wistar rats (270-350 g) with electrolytic lesion (N = 11) and sham-lesioned controls (N = 12). When HD was measured for 60 min on an elevated open platform, lesioned rats emitted 13 times more HD than controls (264.7 ± 93.3 vs 20.3 ± 7.6 episodes), with the difference being statistically significant (P < 0.05). HD counts during 10-min sessions held 7, 14, 21, 27, and 63 days after lesion showed significantly higher means (range: 28.14 ± 5.38 to 62.85 ± 9.48) compared to sham-lesioned controls (range: 7.37 ± 1.13 to 8.5 ± 1.45). Normal rats stepped down into their home cages when the vertical distance between them and the cage was short (16 cm), and the step-down latencies increased with increasing depths (36.7 ± 7.92 to 185.87 ± 35.44 s). Lesioned rats showed a similar behavior when facing the shortest depth, but had a significantly increased number (23.28 ± 2.35 episodes) and latency (300 ± 0.00 s) of HD compared to normal rats (9.25 ± 1.37 episodes and 185.87 ± 35.44 s) when facing the greatest depth (30 cm). This suggests that HD may be a depth-measuring behavior related to risk assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99mTc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Availability of analytical standards is a critical aspect in developing methods for quantitative analysis of anthocyanins. The anthocyanins cyanidin-3-O-glucoside and cyanidin-3-O-rutinoside were isolated from samples of freeze-dried açaí (Euterpe oleraceae Mart.), which is a round and purple well-known palm fruit in Brazil, and then used as standards. The isolation of the anthocyanins was performed by High Performance Liquid Chromatography (HPLC), using an adapted six-channel selection valve. The identification of anthocyanin pigments in açaí was based on mass spectrometric data for molecular ions and MS-MS product ions and on previous published data. After the collection procedure, standards with a high purity grade were obtained and an external standard curve of each anthocyanin was plotted.