58 resultados para Ultrasound (US)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was undertaken in the municipality of Bananal, São Paulo, an endemic area for schistosomiasis with a prevalence under 10% and low parasite load among infected individuals. Our objective was to identify the clinical forms of schistosomiasis among 109 patients in whom the disease had been diagnosed through direct fecal analysis and who had been medicated with oxamniquine at the time of the Plan for the Intensification of Schistosomiasis Control Actions (1998-2000). These patients were submitted to an abdominal ultrasonography and fecal analysis by Kato-Katz method, four years, on average, after the end of the Plan. Five patients, whose abdominal ultrasound images were compatible with either peripheral or central periportal fibrosis and portal hypertension, were identified. None of the 109 patients presented Schistosoma mansoni eggs at fecal analysis. Ultrasonography is a sensitive, noninvasive diagnostic method that allows a better identification of the extent of liver involvement in schistosomiasis cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the findings of abdominal ultrasound and magnetic resonance imaging observed in a patient with advanced schistosomiasis mansoni. A 25-year-old man with hepatosplenic schistosomiasis and variceal bleeding confirmed by upper endoscopy was submitted to abdominal ultrasound and magnetic resonance imaging. During surgery for portal hypertension, a liver biopsy was taken and the diagnosis of Symmers' fibrosis was confirmed. magnetic resonance imaging scans gave more precise information about the gallbladder, periportal thickening and abdominal venous system than did the ultrasound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two hundred and twenty three subjects from a Schistosoma mansoni low morbidity endemic area and nine hospitalized hepatosplenic patients were submitted to stool test and clinical examination and abdomen ultrasound assessments. According to stool examination and ultrasound results, they were grouped as follows: G1 - 63 Schistosoma mansoni egg-negative individuals; G2 - 141 egg-positive patients and without evidence of periportal fibrosis; G3 - 19 egg-positive patients with periportal echogenicity (3-6mm); and G4 - 9 hepatosplenic patients with periportal echogenicity (> 6mm). Hepatomegaly detected by physical examination of the abdomen evaluated in the midclavicular line was verified in G1, G2 and G3, respectively, in 11.1, 12.1 and 26.3%. In G1, G2 and G3, periportal thickening occurred only in schistosomal patients (8.5%). Mild pathological alterations in patients that cannot yet be detected by clinical examination were detectable in the liver by ultrasound and can be due to fibrosis. The degree of mild periportal fibrosis was diminished in 57.9% of patients 12 months after treatment of schistosomiasis with oxamniquine. At ultrasonography, the mean liver left lobe measurement of G3 was larger than that of G1, and that of G4 larger than that of G1 and G2. The mean size of the spleen of G4 was significantly larger than that of the other three groups, and that of G3 larger than that of G1 and G2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdominal ultrasound can be a useful tool for diagnosing periportal fibrosis related to Schistosoma mansoni infection, and also for planning and monitoring the evolution of hepatic morbidity following control measures. We evaluated the standardized ultrasound methodology proposed by the World Health Organization for detecting periportal fibrosis and portal hypertension, among patients from an endemic area in Venezuela, and the impact of praziquantel treatment 3-5 years later. After chemotherapy, complete reversal of periportal lesions was observed in 28.2% of the cases and progression of the disease in 5.1%. Improvement in the hepatic disease started with a reduction in the periportal thickening followed by a decrease in the size of the left hepatic lobe, spleen and mesenteric and spleen veins. Ultrasound confirmed the clinical findings after chemotherapy among the patients with reversal of the disease. However, in patients with more advanced disease, these findings were contradictory. There was no correlation between evolution of the disease seen on ultrasound and age, intensity of infection or serological findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Cardiovascular urgencies are frequent reasons for seeking medical care. Prompt and accurate medical diagnosis is critical to reduce the morbidity and mortality of these conditions.Objective:To evaluate the use of a pocket-size echocardiography in addition to clinical history and physical exam in a tertiary medical emergency care.Methods:One hundred adult patients without known cardiac or lung diseases who sought emergency care with cardiac complaints were included. Patients with ischemic changes in the electrocardiography or fever were excluded. A focused echocardiography with GE Vscan equipment was performed after the initial evaluation in the emergency room. Cardiac chambers dimensions, left and right ventricular systolic function, intracardiac flows with color, pericardium, and aorta were evaluated.Results:The mean age was 61 ± 17 years old. The patient complaint was chest pain in 51 patients, dyspnea in 32 patients, arrhythmia to evaluate the left ventricular function in ten patients, hypotension/dizziness in five patients and edema in one patient. In 28 patients, the focused echocardiography allowed to confirm the initial diagnosis: 19 patients with heart failure, five with acute coronary syndrome, two with pulmonary embolism and two patients with cardiac tamponade. In 17 patients, the echocardiography changed the diagnosis: ten with suspicious of heart failure, two with pulmonary embolism suspicious, two with hypotension without cause, one suspicious of acute coronary syndrome, one of cardiac tamponade and one of aortic dissection.Conclusion:The focused echocardiography with pocket-size equipment in the emergency care may allow a prompt diagnosis and, consequently, an earlier initiation of the therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have identified the specific ultrasonographical (US) changes in Schistosoma japonicum infected patients with the serological changes in general liver function markers. The US examination with the following haematological and biochemical serum analysis was performed on 102 patients in Shistosomiasis Hospital, Leyte, Philippines. The US liver images were classified into 4 patterns according to the development of periportal fibrosis and the patterns of echogenic bands. Among various haematological and biochemical serum parameters of liver damage. The serum levels of total bile acid (TBA) and procollagen-III-peptide (P-III-P) correlated well with the development of hepatic fibrosis and the portal hypertension. These patients were subsequently treated with praziquantel (3 x 20 mg/kg), and improvement of the thickening of the portal vein wall and the dintensity of the echogenic band formation was detected 6 months after treatment. The significant US changes could not be detected in the patients with severe hepatic fibrosis caused in the long term infection. The results revealed that the US examination with the serum TBa level would provider a sensitive tool monitor the severity of the infection and also the improvement occured shortly after praziquantel treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A group of experts on schistosomiasis and ultrasonography discussed the experiences and results obtained with the Niamey-Belo Horizonte Protocol on Ultrasonography in Schistosomiasis. A series of recomendations about qualitative and quantitative data obtained by ultrasound in studies performed in Africa and Brazil are presented. Imunological, genetic and epidemiological studies must rely on ultrasound for the identification of patients with periportal thickening/fibrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major advance in our understanding of the natural history of Schistosoma haematobium-related morbidity has come through the introduction of the portable ultrasound machines for non-invasive examination of the kidneys and bladder. With the use of generators or battery packs to supply power in non-clinical field settings, and with the use of instant photography or miniaturized thermal printers to record permanent images, it is possible to examine scores of individuals in endemic communities every day. Broad-based ultrasound screening has allowed better definition of age-specific disease risks in urinary schistosomiasis. Results indicate that urinary tract abnormalities are common (18% overall prevalence) in S. haematobium transmission areas, with a 2-4% risk of either severe bladder abnormality or advanced ureteral obstruction. In longitudinal surveys, ultrasound studies have shown that praziquantel and metrifonate therapy are rapidly effective in reversing urinary tract abnormalities among children. The benefits of treating adults are less well known, but research in progress should help to define this issue. Similarly, the prognosis of specific ultrasound findings needs to be clarified, and the ease of sonographic examination will make such long-term follow-up studies feasible. In summary, the painless, quick, and reproducible ultrasound examination has become an essential tool in the study of urinary schistosomiasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In endemic areas with low prevalence and low intensity of infection, the diagnosis of hepatic pathology due to the Schistosoma mansoni infection is very difficult. In order to establish the hepatic morbidity, a double-blind study was achieved in Venezuelan endemic areas, with one group of patients with schistosomiasis and the other one of non-infected people, that were evaluated clinically and by abdominal ultrasound using the Cairo classification. Schistosomiasis diagnosis was established based on parasitologic and serological tests. The increase of the hepatic size at midclavicular and midsternal lines (in hepatometry) and the hard liver consistency were the clinical parameters able to differentiate infected persons from non infected ones, as well as the presence of left lobe hepatomegaly detected by abdominal ultrasound. The periportal thickening, especially the mild form, was frequent in all age groups in both infected and uninfected patients. There was not correlation between the intensity of infection and ultrasound under the current circumstances. Our data suggest that in Venezuela, a low endemic area of transmission of schistosomiasis, the hepatic morbidity is mild and uncommon. The Cairo classification seems to overestimate the prevalence of periportal pathology. The specificity of the method must be improved, especially for the recognition of precocious pathology. Other causes of hepatopathies must be investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Brazilian variant of human immunodeficiency virus type 1 (HIV-1) subtype B, (serotype B"-GWGR), has a tryptophan replacing the proline in position 328 the HIV-1 envelope. A longer median time period from infection to acquired immunodeficiency syndrome (AIDS) for serotype B (B"-GWGR) infected subjects compared to the B-GPGR US/European strain was reported. In a cohort study, in São Paulo city, 10 B"-GWGR patients had a statistically significant increased avidity of the anti-V3 antibodies, from 79% ± 33% to 85% ± 75%, versus from 48% ± 59% to 32% ± 17% for the 10 B-GPGR subjects (p = 0.02). The T CD4+ cells showed a mean increase of + 0.45 cells/month for the B-GPGR subjects and for B"-GWGR the slope was + 1.24 cells/month (p = 0.06), for 62 and 55 months of follow up, respectively. RNA plasma viral load decreased from 3.98 ± 1.75 to 2.16 ± 1.54 log10 in the B"-GWGR group while B-GPGR patients showed one log10 reduction in viral load from 4.09 ± 0.38 to 3.17 ± 1.47 log10 over time (p = 0.23), with a decreasing slope of 0.0042 ± log10,/month and 0.0080 ± log10/month, for B-GPGR and B"-GWGR patients, respectively (p = 0.53). Neither group presented any AIDS defining events during the study, according to Center for Diseases Control criteria. Although the sample size is small, these results may indicate that differences in the pathogenicity of the 2 HIV-1 B serotypes which co-circulate in Brazil may be correlated to the avidity of anti-V3 antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Significant advances were made in the diagnosis of filariasis in the 1990s with the emergence of three new alternative tools: ultrasound and tests to detect circulating antigen using two monoclonal antibodies, Og4C3 and AD12-ICT-card. This study aimed to identify which of these methods is the most sensitive for diagnosis of infection. A total of 256 individuals, all male and carrying microfilariae (1-15,679 MF/mL), diagnosed by nocturnal venous blood samples, were tested by all three techniques. The tests for circulating filarial antigen concurred 100% and correctly identified 246/256 (96.69%) of the positive individuals, while ultrasound detected only 186/256 (73.44%). Of the circulating antigen tests, ICT-card was the most convenient method for identification of Wuchereria bancrofti carriers. It was easy to perform, practical and quick.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess interobserver agreement of ultrasound parameters for portal hypertension in hepatosplenic mansonic schistosomiasis. Spleen size, diameter of the portal, splenic and superior mesenteric veins and presence of thrombosis and cavernous transformation were determined by three radiologists in blinded and independent fashion in 30 patients. Interobserver agreement was measured by the kappa index and intraclass correlation coefficient. Interobserver agreement was considered substantial (κ = 0.714-0.795) for portal vein thrombosis and perfect (κ = 1) for cavernous transformation. Interobserver agreement measured by the intraclass correlation coefficient was excellent for longitudinal diameter of the spleen (r = 0.828-0.869) and splenic index (r = 0.816-0.905) and varied from fair to almost perfect for diameter of the portal (r = 0.622-0.675), splenic (r = 0.573-0.913) and superior mesenteric (r = 0.525-0.607) veins. According to the results, ultrasound is a highly reproducible method for the main morphological parameters of portal hypertension in schistosomiasis patients.