19 resultados para Thread safe parallel run-time
Resumo:
When the offset of a visual stimulus (GAP condition) precedes the onset of a target, saccadic reaction times are reduced in relation to the condition with no offset (overlap condition) - the GAP effect. However, the existence of the GAP effect for manual responses is still controversial. In two experiments using both simple (Experiment 1, N = 18) and choice key-press procedures (Experiment 2, N = 12), we looked for the GAP effect in manual responses and investigated possible contextual influences on it. Participants were asked to respond to the imperative stimulus that would occur under different experimental contexts, created by varying the array of warning-stimulus intervals (0, 300 and 1000 ms) and conditions (GAP and overlap): i) intervals and conditions were randomized throughout the experiment; ii) conditions were run in different blocks and intervals were randomized; iii) intervals were run in different blocks and conditions were randomized. Our data showed that no GAP effect was obtained for any manipulation. The predictability of stimulus occurrence produced the strongest influence on response latencies. In Experiment 1, simple manual responses were shorter when the intervals were blocked (247 ms, P < 0.001) in relation to the other two contexts (274 and 279 ms). Despite the use of choice key-press procedures, Experiment 2 produced a similar pattern of results. A discussion addressing the critical conditions to obtain the GAP effect for distinct motor responses is presented. In short, our data stress the relevance of the temporal allocation of attention for behavioral performance.
Resumo:
Myocardial contrast echocardiography has been used for assessing myocardial perfusion. Some concerns regarding its safety still remain, mainly regarding the induction of microvascular alterations. We sought to determine the bioeffects of microbubbles and real-time myocardial contrast echocardiography (RTMCE) in a closed-chest canine model. Eighteen mongrel dogs were randomly assigned to two groups. Nine were submitted to continuous intravenous infusion of perfluorocarbon-exposed sonicated dextrose albumin (PESDA) plus continuous imaging using power pulse inversion RTMCE for 180 min, associated with manually deflagrated high-mechanical index impulses. The control group consisted of 3 dogs submitted to continuous imaging using RTMCE without PESDA, 3 dogs received PESDA alone, and 3 dogs were sham-operated. Hemodynamics and cardiac rhythm were monitored continuously. Histological analysis was performed on cardiac and pulmonary tissues. No hemodynamic changes or cardiac arrhythmias were observed in any group. Normal left ventricular ejection fraction and myocardial perfusion were maintained throughout the protocol. Frequency of mild and focal microhemorrhage areas in myocardial and pulmonary tissue was similar in PESDA plus RTMCE and control groups. The percentages of positive microscopical fields in the myocardium were 0.4 and 0.7% (P = NS) in the PESDA plus RTMCE and control groups, respectively, and in the lungs they were 2.1 and 1.1%, respectively (P = NS). In this canine model, myocardial perfusion imaging obtained with PESDA and RTMCE was safe, with no alteration in cardiac rhythm or left ventricular function. Mild and focal myocardial and pulmonary microhemorrhages were observed in both groups, and may be attributed to surgical tissue manipulation.
Resumo:
The objective of the present study was to determine the oral motor capacity and the feeding performance of preterm newborn infants when they were permitted to start oral feeding. This was an observational and prospective study conducted on 43 preterm newborns admitted to the Neonatal Intensive Care Unit of UFSM, RS, Brazil. Exclusion criteria were the presence of head and neck malformations, genetic disease, neonatal asphyxia, intracranial hemorrhage, and kernicterus. When the infants were permitted to start oral feeding, non-nutritive sucking was evaluated by a speech therapist regarding force (strong vs weak), rhythm (rapid vs slow), presence of adaptive oral reflexes (searching, sucking and swallowing) and coordination between sucking, swallowing and respiration. Feeding performance was evaluated on the basis of competence (defined by rate of milk intake, mL/min) and overall transfer (percent ingested volume/total volume ordered). The speech therapist's evaluation showed that 33% of the newborns presented weak sucking, 23% slow rhythm, 30% absence of at least one adaptive oral reflex, and 14% with no coordination between sucking, swallowing and respiration. Mean feeding competence was greater in infants with strong sucking fast rhythm. The presence of sucking-swallowing-respiration coordination decreased the days for an overall transfer of 100%. Evaluation by a speech therapist proved to be a useful tool for the safe indication of the beginning of oral feeding for premature infants.
Resumo:
The DNA extraction is a critical step in Genetically Modified Organisms analysis based on real-time PCR. In this study, the CTAB and DNeasy methods provided good quality and quantity of DNA from the texturized soy protein, infant formula, and soy milk samples. Concerning the Certified Reference Material consisting of 5% Roundup Ready® soybean, neither method yielded DNA of good quality. However, the dilution test applied in the CTAB extracts showed no interference of inhibitory substances. The PCR efficiencies of lectin target amplification were not statistically different, and the coefficients of correlation (R²) demonstrated high degree of correlation between the copy numbers and the threshold cycle (Ct) values. ANOVA showed suitable adjustment of the regression and absence of significant linear deviations. The efficiencies of the p35S amplification were not statistically different, and all R² values using DNeasy extracts were above 0.98 with no significant linear deviations. Two out of three R² values using CTAB extracts were lower than 0.98, corresponding to lower degree of correlation, and the lack-of-fit test showed significant linear deviation in one run. The comparative analysis of the Ct values for the p35S and lectin targets demonstrated no statistical significant differences between the analytical curves of each target.