18 resultados para Single Phase Grid Connected Inverter


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A liquid phase blocking ELISA (LPB-ELISA) was developed for the detection and measurement of antibodies against infectious bronchitis virus (IBV). The purified and nonpurified virus used as antigen, the capture and detector antibodies, and the chicken hyperimmune sera were prepared and standardized for this purpose. A total of 156 sera from vaccinated and 100 from specific pathogen-free chickens with no recorded contact with the virus were tested. The respective serum titers obtained in the serum neutralization test (SNT) were compared with those obtained in the LPB-ELISA. There was a high correlation (r2 = 0.8926) between the two tests. The LPB-ELISA represents a single test suitable for the rapid detection of antibodies against bronchitis virus in chicken sera, with good sensitivity (88%), specificity (100%) and agreement (95.31%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe the expression of an anti-Z-DNA single chain variable region antibody fragment (scFv) on a filamentous phage surface. Four vectors for phage display were constructed. Two of them are able to display multiple copies of the antibody fragment, and the others can be used to make monovalent libraries. The vectors use different promoter/leader sequences to direct the expression of the fused proteins. All were able to promote the assembly of fusion virion particles. In this paper we also show the affinity selection (biopanning) of those phage-antibodies based on the capacity of their products to recognize the antigen. We used biotinylated Z-DNA and the selection was performed in a solution phase fashion. The data presented here indicate that these vectors can be further used to construct anti-nucleic acid antibody fragment libraries that can be used to study the basis of nucleic acid-protein interaction and its role in autoimmunity mechanisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Tuberculosis is a common opportunistic infection in renal transplant patients. Objective: To obtain a clinical and laboratory description of transplant patients diagnosed with tuberculosis and their response to treatment during a period ranging from 2005 to 2013 at the Pablo Tobón Uribe Hospital. Methods: Retrospective and descriptive study. Results: In 641 renal transplants, tuberculosis was confirmed in 12 cases. Of these, 25% had a history of acute rejection, and 50% had creatinine levels greater than 1.5 mg/dl prior to infection. The disease typically presented as pulmonary (50%) and disseminated (33.3%). The first phase of treatment consisted of 3 months of HZRE (isoniazid, pyrazinamide, rifampicin and ethambutol) in 75% of the cases and HZME (isoniazid, pyrazinamide, moxifloxacin and ethambutol) in 25% of the cases. During the second phase of the treatment, 75% of the cases received isoniazid and rifampicin, and 25% of the cases received isoniazid and ethambutol. The length of treatment varied between 6 and 18 months. In 41.7% of patients, hepatotoxicity was associated with the beginning of anti-tuberculosis therapy. During a year-long follow-up, renal function remained stable, and the mortality rate was 16.7%. Conclusion: Tuberculosis in the renal transplant population studied caused diverse nonspecific symptoms. Pulmonary and disseminated tuberculosis were the most frequent forms and required prolonged treatment. Antituberculosis medications had a high toxicity and mortality. This infection must be considered when patients present with a febrile syndrome of unknown origin, especially during the first year after renal transplant.