57 resultados para Reliability in automation
Resumo:
The Program for Schistosomiasis Control within the Unified Health System (PCE-SUS) was implemented by 1999 in the Rainforest Zone or "Zona da Mata" of Pernambuco (ZMP) aiming to carry out biennial stool surveys of whole populations through municipal health organs followed by treatment of the positives through the local units of the Family Health Program (PSF). Yearly reports from the Health Department of Pernambuco State (SES/PE) from 2002 to 2004 on the PCE-SUS surveys were assessed to evaluate whether the current estimates of prevalence in the municipalities of the ZMP are based on reliable samples so as to allow considerations on the real situation of schistosomiasis in that area. The surveys carried out in that period did not follow the major principles underlying sampling design, thus posing problems in both precision and validity of the estimates. Only 12 out of 43 municipalities had minimally reliable estimates: five with moderate prevalence (10-50%) and seven with low prevalence (< 10%). Surveys with appropriate sampling procedures aimed either at representative target groups (school-aged children) or communities are recommended for the ZMP and other endemic areas not only to provide reliable information on the current situation of schistosomiasis but also to plan adequate control strategies.
Resumo:
Many patients with Chagas disease live in remote communities that lack both equipment and trained personnel to perform a diagnosis by conventional serology (CS). Thus, reliable tests suitable for use under difficult conditions are required. In this study, we evaluated the ability of personnel with and without laboratory skills to perform immunochromatographic (IC) tests to detect Chagas disease at a primary health care centre (PHCC). We examined whole blood samples from 241 patients and serum samples from 238 patients. Then, we calculated the percentage of overall agreement (POA) between the two groups of operators for the sensitivity (S), specificity (Sp) and positive (PPV) and negative (NPV) predictive values of IC tests compared to CS tests. We also evaluated the level of agreement between ELISAs and indirect haemagglutination (IHA) tests. The readings of the IC test results showed 100% agreement (POA = 1). The IC test on whole blood showed the following values: S = 87.3%; Sp = 98.8%; PPV = 96.9% and NPV = 95.9%. Additionally, the IC test on serum displayed the following results: S = 95.7%; Sp = 100%; PPV = 100% and NPV = 98.2%. Using whole blood, the agreement with ELISA was 96.3% and the agreement with IHA was 94.1%. Using serum, the agreement with ELISA was 97.8% and the agreement with IHA was 96.6%. The IC test performance with serum samples was excellent and demonstrated its usefulness in a PHCC with minimal equipment. If the IC test S value and NPV with whole blood are improved, then this test could also be used in areas lacking laboratories or specialised personnel.
Resumo:
This study had as its objective to analyze the intraclass reliability of the Alberta Infant Motor Scale (AIMS), in the Brazilian version, in preterm and term infants. It was a methodological study, conducted from November 2009 to April 2010, with 50 children receiving care in two public institutions in Fortaleza, Ceará, Brazil. Children were grouped according to gestational age as preterm and term, and evaluated by three evaluators in the communication laboratory of a public institution or at home. The intraclass correlation indices for the categories prone, supine, sitting and standing ranged from 0.553 to 0.952; most remained above 0.800, except for the standing category of the third evaluator, in which the index was 0.553. As for the total score and percentile, rates ranged from 0.843 to 0.954. The scale proved to be a reliable instrument for assessing gross motor performance of Brazilian children, particularly in Ceará, regardless of gestational age at birth.
Resumo:
Using a sample of patients with coronary artery disease, this methodological study aimed to conduct a cross-cultural adaptation and validation of a questionnaire on knowledge of cardiovascular risk factors (Q-FARCS), lifestyle changes, and treatment adherence for use in Brazil. The questionnaire has three scales: general knowledge of risk factors (RFs); specific knowledge of these RFs; and lifestyle changes achieved. Cross-cultural adaptation included translation, synthesis, back-translation, expert committee review, and pretesting. Face and content validity, reliability, and construct validity were measured. Cronbach’s alpha for the total sample (n = 240) was 0.75. Assessment of psychometric properties revealed adequate face and content validity, and the construct revealed seven components. It was concluded that the Brazilian version of Q-FARCS had adequate reliability and validity for the assessment of knowledge of cardiovascular RFs.
Resumo:
The main characteristic of the nursing Interactive Observation Scale for Psychiatric Inpatients (IOSPI) is the necessity of interaction between raters and patients during assessment. The aim of this study was to evaluate the reliability and validity of the scale in the "real" world of daily ward practice and to determine whether the IOSPI can increase the interaction time between raters and patients and influence the raters' opinion about mental illness. All inpatients of a general university hospital psychiatric ward were assessed daily over a period of two months by 9 nursing aides during the morning and afternoon shifts, with 273 pairs of daily observations. Once a week the patients were interviewed by a psychiatrist who filled in the Brief Psychiatric Rating Scale (BPRS). The IOSPI total score was found to show significant test-retest reliability (interclass correlation coefficient = 0.83) and significant correlation with the BPRS total score (r = 0.69), meeting the criteria of concurrent validity. The instrument can also discriminate between patients in need of further inpatient treatment from those about to be discharged (negative predictive value for discharge = 0.91). Using this scale, the interaction time between nursing aides and patients increased significantly (t = 2.93, P<0.05) and their opinion about the mental illness changed. The "social restrictiveness" factor of the opinion scale about mental illness showed a significant reduction (t = 4.27, P<0.01) and the "interpersonal etiology" factor tended to increase (t = 1.98, P = 0.08). The IOSPI was confirmed as a reliable and valid scale and as an efficient tool to stimulate the therapeutic attitudes of the nursing staff.
Resumo:
The objective of the present study was to evaluate the reliability and clinical utility of a Portuguese version of the Abnormal Involuntary Movements Scale (AIMS). Videotaped interviews with 16 psychiatric inpatients treated with antipsychotic drugs for at least 5 years were evaluated. Reliability was assessed by the intraclass correlation coefficient (ICC) between three raters, two with and one without clinical training in psychopathology. Clinical utility was assessed by the difference between the scores of patients with (N = 11) and without (N = 5) tardive dyskinesia (TD). Patients with TD exhibited a higher severity of global evaluation by the AIMS (sum of scores: 4.2 ± 0.9 vs 0.4 ± 0.2; score on item 8: 2.3 ± 0.3 vs 0.4 ± 0.2, TD vs controls). The ICC for the global evaluation was fair between the two skilled raters (0.58-0.62) and poor between these raters and the rater without clinical experience (0.05-0.29). Thus, we concluded that the Portuguese version of the AIMS shows an acceptable inter-rater reliability, but only between clinically skilled raters, and that it is clinically useful.
Resumo:
Studies on the assessment of heart rate variability threshold (HRVT) during walking are scarce. We determined the reliability and validity of HRVT assessment during the incremental shuttle walk test (ISWT) in healthy subjects. Thirty-one participants aged 57 ± 9 years (17 females) performed 3 ISWTs. During the 1st and 2nd ISWTs, instantaneous heart rate variability was calculated every 30 s and HRVT was measured. Walking velocity at HRVT in these tests (WV-HRVT1 and WV-HRVT2) was registered. During the 3rd ISWT, physiological responses were assessed. The ventilatory equivalents were used to determine ventilatory threshold (VT) and the WV at VT (WV-VT) was recorded. The difference between WV-HRVT1 and WV-HRVT2 was not statistically significant (median and interquartile range = 4.8; 4.8 to 5.4 vs4.8; 4.2 to 5.4 km/h); the correlation between WV-HRVT1 and WV-HRVT2 was significant (r = 0.84); the intraclass correlation coefficient was high (0.92; 0.82 to 0.96), and the agreement was acceptable (-0.08 km/h; -0.92 to 0.87). The difference between WV-VT and WV-HRVT2 was not statistically significant (4.8; 4.8 to 5.4 vs 4.8; 4.2 to 5.4 km/h) and the agreement was acceptable (0.04 km/h; -1.28 to 1.36). HRVT assessment during walking is a reliable measure and permits the estimation of VT in adults. We suggest the use of the ISWT for the assessment of exercise capacity in middle-aged and older adults.
Resumo:
INTRODUCTION: Self-reported weight and height were compared with direct measurements in order to evaluate the agreement between the two sources. METHOD: Data were obtained from a cross-sectional study on health status from a probabilistic sample of 1,183 employees of a bank, in Rio de Janeiro State, Brazil. Direct measurements were made of 322 employees. Differences between the two sources were evaluated using mean differences, limits of agreement and intraclass correlation coefficient (ICC). RESULTS AND CONCLUSIONS: Men and women tended to underestimate their weight while differences between self-reported and measured height were insignificant. Body mass index (BMI) mean differences were smaller than those observed for weight. ICC was over 0.98 for weight and 0.95 for BMI, expressing close agreement. Combining a graphical method with ICC may be useful in pilot studies to detect populational groups capable of providing reliable information on weight and height, thus minimizing resources needed for field work.
Resumo:
OBJECTIVE: To analyze reliability of a self-applied questionnaire on substance use and misuse among adolescent students. METHODS: Two cross-sectional studies were carried out for the instrument test-retest. The sample comprised male and female students aged 1119 years from public and private schools (elementary, middle, and high school students) in the city of Salvador, Northeastern Brazil, in 2006. A total of 591 questionnaires were applied in the test and 467 in the retest. Descriptive statistics, the Kappa index, Cronbach's alpha and intraclass correlation were estimated. RESULTS: The prevalence of substance use/misuse was similar in both test and retest. Sociodemographic variables showed a "moderate" to "almost perfect" agreement for the Kappa index, and a "satisfactory" (>0.75) consistency for Cronbach's alpha and intraclass correlation. The age which psychoactive substances (tobacco, alcohol, and cannabis) were first used and chronological age were similar in both studies. Test-retest reliability was found to be a good indicator of students' age of initiation and their patterns of substance use. CONCLUSIONS: The questionnaire reliability was found to be satisfactory in the population studied.
Resumo:
OBJECTIVE : To compare the reliability and convergent validity of instruments assessing quality of life in Brazilian older adults. METHODS : Cross-sectional study of 278 literate, community-dwelling older adults attending a municipal university for the elderly in Sao Carlos, SP, Southeastern Brazil between 2006 and 2008. The Brazilian versions of the SF-36 and WHOQOL-BREF instruments to assess quality of life were compared. Cronbach’s alpha coefficient was used to estimate reliability and Pearson’s correlation for comparison between the two scales. RESULTS : Most of participants were women (87.8%) with a mean age of 63.83±7.22 years. Both scales showed an acceptable internal consistency – WHOQOL-BREF Cronbach’s alpha was 0.832 and SF-36 was 0.868. There was a weak (r ≤ 0.6) correlation between the related fields in the two questionnaires. CONCLUSIONS : The SF-36 and WHOQOL-BREF are reliable instruments for clinical and research uses in Brazilian older women. To select one, researchers should consider which aspects of quality of life they aim to capture because of weak convergent validity signs. This study’s results indicate that WHOQOL-BREF may be more relevant to evaluate changes in the quality of life of older women because it prioritizes responses to the aging process and avoids focusing on impairment.
Resumo:
OBJECTIVE To validate a screening instrument using self-reported assessment of frailty syndrome in older adults.METHODS This cross-sectional study used data from the Saúde, Bem-estar e Envelhecimento study conducted in Sao Paulo, SP, Southeastern Brazil. The sample consisted of 433 older adult individuals (≥ 75 years) assessed in 2009. The self-reported instrument can be applied to older adults or their proxy respondents and consists of dichotomous questions directly related to each component of the frailty phenotype, which is considered the gold standard model: unintentional weight loss, fatigue, low physical activity, decreased physical strength, and decreased walking speed. The same classification proposed in the phenotype was utilized: not frail (no component identified); pre-frail (presence of one or two components), and frail (presence of three or more components). Because this is a screening instrument, “process of frailty” was included as a category (pre-frail and frail). Cronbach’s α was used in psychometric analysis to evaluate the reliability and validity of the criterion, the sensitivity, the specificity, as well as positive and negative predictive values. Factor analysis was used to assess the suitability of the proposed number of components.RESULTS Decreased walking speed and decreased physical strength showed good internal consistency (α = 0.77 and 0.72, respectively); however, low physical activity was less satisfactory (α = 0.63). The sensitivity and specificity for identifying pre-frail individuals were 89.7% and 24.3%, respectively, while those for identifying frail individuals were 63.2% and 71.6%, respectively. In addition, 89.7% of the individuals from both the evaluations were identified in the “process of frailty” category.CONCLUSIONS The self-reported assessment of frailty can identify the syndrome among older adults and can be used as a screening tool. Its advantages include simplicity, rapidity, low cost, and ability to be used by different professionals.
Resumo:
OBJECTIVE To evaluate the validity and reliability of an instrument that evaluates the structure of primary health care units for the treatment of tuberculosis.METHODS This cross-sectional study used simple random sampling and evaluated 1,037 health care professionals from five Brazilian municipalities (Natal, state of Rio Grande do Norte; Cabedelo, state of Paraíba; Foz do Iguaçu, state of Parana; Sao José do Rio Preto, state of Sao Paulo, and Uberaba, state of Minas Gerais) in 2011. Structural indicators were identified and validated, considering different methods of organization of the health care system in the municipalities of different population sizes. Each structure represented the organization of health care services and contained the resources available for the execution of health care services: physical resources (equipment, consumables, and facilities); human resources (number and qualification); and resources for maintenance of the existing infrastructure and technology (deemed as the organization of health care services). The statistical analyses used in the validation process included reliability analysis, exploratory factor analysis, and confirmatory factor analysis.RESULTS The validation process indicated the retention of five factors, with 85.9% of the total variance explained, internal consistency between 0.6460 and 0.7802, and quality of fit of the confirmatory factor analysis of 0.995 using the goodness-of-fit index. The retained factors comprised five structural indicators: professionals involved in the care of tuberculosis patients, training, access to recording instruments, availability of supplies, and coordination of health care services with other levels of care. Availability of supplies had the best performance and the lowest coefficient of variation among the services evaluated. The indicators of assessment of human resources and coordination with other levels of care had satisfactory performance, but the latter showed the highest coefficient of variation. The performance of the indicators “training” and “access to recording instruments” was inferior to that of other indicators.CONCLUSIONS The instrument showed feasibility of application and potential to assess the structure of primary health care units for the treatment of tuberculosis.
Resumo:
ABSTRACTOBJECTIVE To assess inter-rater reliability, test-retest reliability, and construct validity of retail food store, open-air food market, and restaurant observation tools adapted to the Brazilian urban context.METHODS This study is part of a cross-sectional observation survey conducted in 13 districts across the city of Sao Paulo, Brazil in 2010-2011. Food store and restaurant observational tools were developed based on previously available tools, and then tested it. They included measures on the availability, variety, quality, pricing, and promotion of fruits and vegetables and ultra-processed foods. We used Kappa statistics and intra-class correlation coefficients to assess inter-rater and test-retest reliabilities in samples of 142 restaurants, 97 retail food stores (including open-air food markets), and of 62 restaurants and 45 retail food stores (including open-air food markets), respectively. Construct validity as the tool’s abilities to discriminate based on store types and different income contexts were assessed in the entire sample: 305 retail food stores, 8 fruits and vegetable markets, and 472 restaurants.RESULTS Inter-rater and test-retest reliability were generally high, with most Kappa values greater than 0.70 (range 0.49-1.00). Both tools discriminated between store types and neighborhoods with different median income. Fruits and vegetables were more likely to be found in middle to higher-income neighborhoods, while soda, fruit-flavored drink mixes, cookies, and chips were cheaper and more likely to be found in lower-income neighborhoods.CONCLUSIONS The measures were reliable and able to reveal significant differences across store types and different contexts. Although some items may require revision, results suggest that the tools may be used to reliably measure the food stores and restaurant food environment in urban settings of middle-income countries. Such studies can help .inform health promotion interventions and policies in these contexts.
Resumo:
ABSTRACT OBJECTIVE : To evaluate the validity and reliability of the Questionnaire for Compliance with Standard Precaution for nurses. METHODS : This methodological study was conducted with 121 nurses from health care facilities in Sao Paulo's countryside, who were represented by two high-complexity and by three average-complexity health care facilities. Internal consistency was calculated using Cronbach's alpha and stability was calculated by the intraclass correlation coefficient, through test-retest. Convergent, discriminant, and known-groups construct validity techniques were conducted. RESULTS : The questionnaire was found to be reliable (Cronbach's alpha: 0.80; intraclass correlation coefficient: (0.97) In regards to the convergent and discriminant construct validity, strong correlation was found between compliance to standard precautions, the perception of a safe environment, and the smaller perception of obstacles to follow such precautions (r = 0.614 and r = 0.537, respectively). The nurses who were trained on the standard precautions and worked on the health care facilities of higher complexity were shown to comply more (p = 0.028 and p = 0.006, respectively). CONCLUSIONS : The Brazilian version of the Questionnaire for Compliance with Standard Precaution was shown to be valid and reliable. Further investigation must be conducted with nurse samples that are more representative of the Brazilian reality. The use of the questionnaire may support the creation of educational measures considering the possible gaps that can be identified, focusing on the workers' health and on the patients' safety.
Resumo:
INTRODUCTION: Human serofrequency of antibodies against Taenia solium antigens was determined and risk factors for cysticercosis transmission were identified. METHODS: Individuals (n=878) from periurban and rural locations of Lages, SC, were interviewed to gather demographic, sanitary and health information. Interviews and blood sample collections by finger prick on Whatman filter paper were performed from August 2004 to May 2005. Observation determined that 850 samples were suitable for analysis and were tested by ELISA using vesicular fluid of Taenia crassiceps heterologous antigen. To ensure the reliability of the results, 77 samples of the dried blood were matched with sera. The reactive samples were submitted to a serum confirmatory immunoblot (IB) test using purified Taenia crassiceps glycoproteins. RESULTS: The ELISA results for the dried blood and serum samples were statistically consistent. ELISA was positive in 186 (21.9%) out of 850 individuals. A group of 213 individuals were asked to collect vein blood for IB (186 with positive result in ELISA and 27 with inappropriate whole blood samples) and 130 attended the request. The IB was positive in 29 (3.4%) out of 850 individuals. A significant correlation (p = 0.0364) was determined among individuals who tested positive in the IB assay who practiced both pig rearing and kitchen gardening. CONCLUSIONS: ELISA with dried blood eluted from filter paper was suitable for cysticercosis population surveys. In Lages, human infection was associated with pig rearing and kitchen gardening. The prevalence index was compatible with other Latin American endemic areas.