58 resultados para Radiological safety


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The authors analyzed the 30-day and 6-month outcomes of 1,126 consecutive patients who underwent coronary stent implantation in 1996 and 1997. METHODS: The 30-day results and 6-month angiographic follow-up were analyzed in patients treated with coronary stents in 1996 and 1997. All patients underwent coronary stenting with high-pressure implantation (>12 atm) and antiplatelet drug regimen (aspirin plus ticlopidine). RESULTS: During the study period, 1,390 coronary stents were implanted in 1,200 vessels of 1,126 patients; 477 patients were treated in the year 1996 and 649 in 1997. The number of percutaneous procedures performed using stents increased significantly in 1997 compared to 1996 (64 % vs 48%, p=0.0001). The 30-day results were similar in both years; the success and stent thrombosis rates were equal (97% and 0.8%, respectively). The occurrence of new Q wave MI (1.3% vs 1.1%, 1996 vs 1997, p=NS), emergency coronary bypass surgery (1% vs 0.6%, 1996 vs 1997, p=NS) and 30-day death rates (0.2% vs 0.5%, 1996 vs 1997, p=NS) were similar. The 6-month restenosis rate was 25% in 1996 and 27% in 1997 (p= NS); the target vessel revascularization rate was 15% in 1996 and 16% in 1997 (p = NS). CONCLUSIONS: Intracoronary stenting showed a high success rate and a low incidence of 30-day occurrence of new major coronary events in both periods, despite the greater angiographic complexity of the patients treated with in 1997. These adverse variables did not have a negative influence at the 6-month clinical and angiographic follow-up, with similar rates of restenosis and ischemia-driven target lesion revascularization rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess safety and efficacy of coronary angioplasty with stent implantation in unstable coronary syndromes. METHODS: Retrospective analysis of in-hospital and late evolution of 74 patients with unstable coronary syndromes (unstable angina or infarction without elevation of the ST segment) undergoing coronary angioplasty with stent placement. These 74 patients were compared with 31 patients with stable coronary syndromes (stable angina or stable silent ischemia) undergoing the same procedure. RESULTS: No death and no need for revascularization of the culprit artery occurred in the in-hospital phase. The incidences of acute non-Q-wave myocardial infarction were 1.4% and 3.2% (p=0.6) in the unstable and stable coronary syndrome groups, respectively. In the late follow-up (11.2±7.5 months), the incidences of these events combined were 5.7% in the unstable coronary syndrome group and 6.9% (p=0.8) in the stable coronary syndrome group. In the multivariate analysis, the only variable with a tendency to significance as an event predictor was diabetes mellitus (p=0.07; OR=5.2; 95% CI=0.9-29.9). CONCLUSION: The in-hospital and late evolutions of patients with unstable coronary syndrome undergoing angioplasty with intracoronary stent implantation are similar to those of the stable coronary syndrome group, suggesting that this procedure is safe and efficacious when performed in unstable coronary syndrome patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intracoronary brachytherapy using beta or gamma radiation is currently the most efficient type of therapy for preventing the recurrence of coronary in-stent restenosis. Its implementation depends on the interaction among interventionists, radiotherapists, and physicists to assure the safety and quality of the method. The authors report the pioneering experience in Brazil of the treatment of 2 patients with coronary in-stent restenosis, in whom beta radiation was used as part of the international multicenter randomized PREVENT study (Proliferation REduction with Vascular ENergy Trial). The procedures were performed rapidly and did not require significant modifications in the traditional techniques used for conventional angioplasty. Alteration in the radiological protection devices of the hemodynamic laboratory were also not required, showing that intracoronary brachytherapy using beta radiation can be incorporated into the interventional tools of cardiology in our environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the efficacy and tolerability of telmisartan, given once a day to patients with mild to moderate hypertension, as well as to assess the 24-hour blood pressure profile with ABPM. METHODS: Initially, 163 patients over 18 were selected, regardless of sex, with blood pressure levels >140/90mmHg at visit 1, which was confirmed at visit 2. One hundred thirty-four patients completed the study. After a 4-week placebo run-in phase, telmisartan 40mg/daily was given for 6 weeks. In those patients whose blood pressure (BP) levels were lower than 140/90mmHg, the same dosage was kept for an additional period of 6 weeks. For those who had BP higher than 140/90mmHg, the dosage was increased to 80mg/daily. Sixty-two patients were included in a subgroup that underwent ABPM 3 different times during the study. RESULTS: In the overall group, blood pressure reduction ranged from 162.3±14.5/101.3±5.75 mmHg (baseline) to 147.3±20.1/90.8±10.9 mmHg (week 12) (p<0.05). Mean blood pressure decreases were 14.4mmHg for systolic BP and 10.3mmHg for diastolic BP, after 12 weeks of active treatment. A subanalysis showed that 47 (35%) patients took telmisartan 40mg throughout the study and 81 (65%) had the dosage increased to 80mg daily. Using ABPM, an 8-mmHg reduction in systolic BP as well as a 5-mmHg reduction in diastolic BP were observed, when compared with baseline values in the final 6 hours (18-24 hours after the last dose of study medication). CONCLUSION: Our results confirm that telmisartan given once a day is effective in reducing blood pressure levels in mild to moderate hypertensive patients. This reduction occurs in a sustained and gradual manner during a 24-hour period confirmed by ABPM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the value of the radiological study of the thorax for diagnosing left ventricular dilation and left ventricular systolic dysfunction in patients with Chagas' disease. METHODS: A cross-sectional study of 166 consecutive patients with Chagas' disease and no other associated diseases. The patients underwent cardiac assessment with chest radiography and Doppler echocardiography. Sensitivity, specificity, and positive and negative predictive values of chest radiography were calculated to detect left ventricular dysfunction and the accuracy of the cardiothoracic ratio in the diagnosis of left ventricular dysfunction with the area below the ROC curve. The cardiothoracic ratio was correlated with the left ventricular ejection fraction and the left ventricular diastolic diameter. RESULTS: The abnormal chest radiogram had a sensitivity of 50%, specificity of 80.5%, and positive and negative predictive values of 51.2% and 79.8%, respectively, in the diagnosis of left ventricular dysfunction. The cardiothoracic ratio showed a weak correlation with left ventricular ejection fraction (r=-0.23) and left ventricular diastolic diameter (r=0.30). The area calculated under the ROC curve was 0.734. CONCLUSION: The radiological study of the thorax is not an accurate indicator of left ventricular dysfunction; its use as a screening method to initially approach the patient with Chagas' disease should be reevaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess safety, feasibility, and the results of early exercise testing in patients with chest pain admitted to the emergency room of the chest pain unit, in whom acute myocardial infarction and high-risk unstable angina had been ruled out. METHODS: A study including 1060 consecutive patients with chest pain admitted to the emergency room of the chest pain unit was carried out. Of them, 677 (64%) patients were eligible for exercise testing, but only 268 (40%) underwent the test. RESULTS: The mean age of the patients studied was 51.7±12.1 years, and 188 (70%) were males. Twenty-eight (10%) patients had a previous history of coronary artery disease, 244 (91%) had a normal or unspecific electrocardiogram, and 150 (56%) underwent exercise testing within a 12-hour interval. The results of the exercise test in the latter group were as follows: 34 (13%) were positive, 191 (71%) were negative, and 43 (16%) were inconclusive. In the group of patients with a positive exercise test, 21 (62%) underwent coronary angiography, 11 underwent angioplasty, and 2 underwent myocardial revascularization. In a univariate analysis, type A/B chest pain (definitely/probably anginal) (p<0.0001), previous coronary artery disease (p<0.0001), and route 2 (patients at higher risk) correlated with a positive or inconclusive test (p<0.0001). CONCLUSION: In patients with chest pain and in whom acute myocardial infarction and high-risk unstable angina had been ruled out, the exercise test proved to be feasible, safe, and well tolerated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Dyslipidemia is the primary risk factor for cardiovascular disease, and statins have been effective in controlling lipid levels. Sex differences in the pharmacokinetics and pharmacodynamics of statins contribute to interindividual variations in drug efficacy and toxicity. Objective: To evaluate the presence of sexual dimorphism in the efficacy and safety of simvastatin/atorvastatin treatment. Methods: Lipid levels of 495 patients (331 women and 164 men) were measured at baseline and after 6 ± 3 months of simvastatin/atorvastatin treatment to assess the efficacy and safety profiles of both drugs. Results: Women had higher baseline levels of total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), and high-density lipoprotein cholesterol (HDL-C) compared with men (p < 0.0001). After treatment, women exhibited a greater decrease in plasma TC and LDL-C levels compared with men. After adjustment for covariates, baseline levels of TC and LDL-C influenced more than 30% of the efficacy of lipid-lowering therapy (p < 0.001), regardless of sex. Myalgia [with or without changes in creatine phosphokinase (CPK) levels] occurred more frequently in women (25.9%; p = 0.002), whereas an increase in CPK and/or abnormal liver function was more frequent in in men (17.9%; p = 0.017). Conclusions: Our results show that baseline TC and LDL-C levels are the main predictors of simvastatin/atorvastatin therapy efficacy, regardless of sex. In addition, they suggest the presence of sexual dimorphism in the safety of simvastatin/atorvastatin. The effect of sex differences on receptors, transporter proteins, and gene expression pathways needs to be better evaluated and characterized to confirm these observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Drug-eluting stents have been used in daily practice since 2002, with the clear advantages of reducing the risk of target vessel revascularization and an impressive reduction in restenosis rate by 50%-70%. However, the occurrence of a late thrombosis can compromise long-term results, particularly if the risks of this event were sustained. In this context, a registry of clinical cases gains special value. Objective: To evaluate the efficacy and safety of drug-eluting stents in the real world. Methods: We report on the clinical findings and 8-year follow-up parameters of all patients that underwent percutaneous coronary intervention with a drug-eluting stent from January 2002 to April 2007. Drug-eluting stents were used in accordance with the clinical and interventional cardiologist decision and availability of the stent. Results: A total of 611 patients were included, and clinical follow-up of up to 8 years was obtained for 96.2% of the patients. Total mortality was 8.7% and nonfatal infarctions occurred in 4.3% of the cases. Target vessel revascularization occurred in 12.4% of the cases, and target lesion revascularization occurred in 8% of the cases. The rate of stent thrombosis was 2.1%. There were no new episodes of stent thrombosis after the fifth year of follow-up. Comparative subanalysis showed no outcome differences between the different types of stents used, including Cypher®, Taxus®, and Endeavor®. Conclusion: These findings indicate that drug-eluting stents remain safe and effective at very long-term follow-up. Patients in the "real world" may benefit from drug-eluting stenting with excellent, long-term results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have compared the efficacy of two Leishmania (Leishmania) major vaccines, one genetically attenuated (DHFR-TS deficient organisms), the other inactivated [autoclaved promastigotes (ALM) with bacillus Calmete-Guérin (BCG)], in protecting rhesus macaques (Macaca mulatta) against infection with virulent L. (L.) major. Positive antigen-specific recall proliferative response was observed in vaccinees (79% in attenuated parasite-vaccinated monkeys, versus 75% in ALM-plus-BCG-vaccinated animals), although none of these animals exhibited either augmented in vitro gamma interferon (IFN-g) production or positive delayed-type hypersensitivity (DTH) response to the leishmanin skin test prior to the challenge. Following challenge, there were significant differences in blastogenic responses (p < 0.05) between attenuated-vaccinated monkeys and naïve controls. In both vaccinated groups very low levels of antibody were found before challenge, which increased after infective challenge. Protective immunity did not follow vaccination, in that monkeys exhibited skin lesion at the site of challenge in all the groups. The most striking result was the lack of pathogenicity of the attenuated parasite, which persisted in infected animals for up to three months, but were incapable of causing disease under the conditions employed. We concluded that both vaccine protocols used in this study are safe in primates, but require further improvement for vaccine application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The immunogenicity and safety of a new recombinant hepatitis B vaccine from the Instituto Butantan (Butang®) were evaluated in a multicenter, double-blind, prospective equivalence study in three centers in Brazil. Engerix B® was the standard vaccine. A total of 3937 subjects were recruited and 2754 (70%) met all protocol criteria at the end of the study. All the subjects were considered healthy and denied having received hepatitis B vaccine before the study. Study subjects who adhered to the protocol were newborn infants (566), children 1 to 10 years old (484), adolescents from 11 to 19 years (740), adults from 20 to 30 years (568), and adults from 31 to 40 years (396). Vaccine was administered in three doses on the schedule 0, 1, and 6 months (newborn infants, adolescents, and adults) or 0, 1, and 7 months (children). Vaccine dose was intramuscular 10 µg (infants, children, and adolescents) or 20 µg (adults). Percent seroprotection (assumed when anti-HBs titers were > 10mIU/ml) and geometric mean titer (mIU/ml) were: newborn infants, 93.7% and 351.1 (Butang®) and 97.5% and 1530.6 (Engerix B®); children, 100% and 3600.0 (Butang®) and 97.7% and 2753.1 (Engerix B®); adolescents, 95.1% and 746.3 (Butang®) and 96% and 1284.3 (Engerix B®); adults 20-30 years old, 91.8% and 453.5 (Butang®) and 95.5% and 1369.0 (Engerix B®); and adults 31-40 years old, 79.8% and 122.7 (Butang®) and 92.4% and 686.2 (Engerix B®). There were no severe adverse events following either vaccine. The study concluded that Butang® was equivalent to Engerix B® in children, and less immunogenic but acceptable for use in newborn infants, adolescents, and young adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical and epidemiological characteristics, adverse events, treatment adherence and effectiveness of isoniazid chemoprophylaxis were analyzed in a cohort of 138 tuberculosis/HIV-coinfected patients. An open, non-randomized, pragmatic prophylactic trial was conducted on adult patients with a normal chest X-ray and positive tuberculin skin test (> 5 mm) who received isoniazid chemoprophylaxis (300 mg/day) for six months. The mean of follow up was 2.8 years (SD 1.3). Adherence to chemoprophylaxis was 87.7% (121/138). Only one patient presented tuberculosis after the end of chemoprophylaxis, corresponding to 0.3 cases per 100 persons per year. The relative risk of some adverse effects was 4.6 times higher (95% CI: 1.9-11.5) in patients with positive anti-HCV serology (4/9, 44.4%) compared to those with negative serology (12/129, 9.6%) (p = 0.002). This study provides evidence regarding the effectiveness and safety of a short and self-administered isoniazid regimen. We recommend the implementation of this routine by health service practitioners.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mosquito-borne diseases such as dengue fever, chikungunya or malaria affect millions of people each year and control solutions are urgently needed. An international research program is currently being developed that relies on the introduction of the bacterial endosymbiont Wolbachia pipientis into Aedes aegypti to control dengue transmission. In order to prepare for open-field testing releases of Wolbachia-infected mosquitoes, an intensive social research and community engagement program was undertaken in Cairns, Northern Australia. The most common concern expressed by the diverse range of community members and stakeholders surveyed was the necessity of assuring the safety of the proposed approach for humans, animals and the environment. To address these concerns a series of safety experiments were undertaken. We report in this paper on the experimental data obtained, discuss the limitations of experimental risk assessment and focus on the necessity of including community concerns in scientific research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present investigation was a cross-sectional, quantitative research study analyzing incidents associated with nursing care using a root-cause methodological analysis. The study was conducted in a public hospital intensive care unit (ICU) in Santiago de Chile and investigated 18 incidents related to nursing care that occurred from January to March of 2012. The sample was composed of six cases involving medications and the self-removal of therapeutic devices. The contributing factors were related to the tasks and technology, the professional work team, the patients, and the environment. The analysis confirmed that the cases presented with similar contributing factors, thereby indicating that the vulnerable aspects of the system are primarily responsible for the incidence occurrence. We conclude that root-cause analysis facilitates the identification of these vulnerable points. Proactive management in system-error prevention is made possible by recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the safety of the performance of the traditional and protected collection techniques of tracheal aspirate and to identify qualitative and quantitative agreement of the results of microbiological cultures between the techniques. Method: Clinical, prospective, comparative, single-blind research. The sample was composed of 54 patients of >18 years of age, undergoing invasive mechanical ventilation for a period of ≥48 hours and with suspected Ventilator Associated Pneumonia. The two techniques were implemented in the same patient, one immediately after the other, with an order of random execution, according to randomization by specialized software. Results: No significant events occurred oxygen desaturation, hemodynamic instability or tracheobronchial hemorrhage (p<0.05) and, although there were differences in some strains, there was qualitative and quantitative agreement between the techniques (p<0.001). Conclusion: Utilization of the protected technique provided no advantage over the traditional and execution of both techniques was safe for the patient.