93 resultados para RESONANCE-SPECTRUM


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Epidemiological data on the prevalence of extended-spectrum β-lactamases (ESBLs) are scarce in Brazil despite the fact that these data are essential for empirical treatment and control measures. The objective of this study was to evaluate the prevalence of different ESBLs by type and distribution in a tertiary hospital in southern Brazil. METHODS: We evaluated 1,827 enterobacterial isolates between August 2003 and March 2008 isolated from patients at a tertiary hospital. Samples were identified using a Vitek automated system and were confirmed by biochemical testing. The identified ESBL strains were characterized by phenotypic methods, polymerase chain reaction (PCR), and sequencing. Genetic similarities were evaluated by pulsed-field gel electrophoresis. RESULTS: It was 390 (21.3%) ESBL-producing strains, which expressed the ESBLs CTX-M (292), SHV (84), CTX and SHV (10), TEM (2), and PER (2). CONCLUSIONS: The prevalence of ESBL-expressing strains was high, especially in Klebsiella pneumoniae and Enterobacter spp. CTX-M was the predominant type of ESBL observed, and its genetic variability indicates a polyclonal distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractINTRODUCTIONThe aim of this study was to detect the prevalence of the extended-spectrum beta-lactamase (ESBL)-encoding CTX-M gene in Escherichia coliisolates.METHODS:Phenotypic screening of 376 E. coli isolates for ESBL was conducted using disk diffusion. ESBL-producing isolates were tested using PCR and specific primers. The blaCTX-M cluster was identified using the RFLP method, and its genotype was sequenced.RESULTS:From 202 ESBL-producing E. coli , 185 (91.5%) possessed CTX-M genes. CTX-M-1 subtypes were found in 98% of the isolates. The blaCTX-M gene was identical to CTX-M-15.CONCLUSIONS:A high prevalence of CTX-M-1-producing E. coli apparently exists in Shiraz, Iran.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: INTRODUCTION: Nosocomial infections are closely associated with antimicrobial drug resistance. One of the most important mechanisms of resistance to β-lactam antibiotics is the production of extended spectrum β-lactamases (ESBLs). The objective of the present study was to evaluate the prevalence and antimicrobial susceptibility profile of ESBL-producing strains and to assess the evolution of antimicrobial drug resistance between 2007 and 2013 at the Hospital São Vicente de Paulo, Passo Fundo, State of Rio Grande do Sul, Brazil. METHODS: We conducted a descriptive, observational, cross-sectional study. Bacterial culture was performed from January to December 2013. The antimicrobial susceptibility profile of these cultures was determined using the disk diffusion method. Phenotypic screening for ESBL production was performed using the disk approximation method. RESULTS : We analyzed a total of 19,112 cultures, 11.5% of which were positive for Enterobacteriaceae. Of these, 30.3% of the isolates were positive for ESBL production, and the most prevalent species was Klebsiella sp. (37.5%). Over 95% of these isolates showed reduced susceptibility to all cephalosporins, aztreonam, and amoxicillin/clavulanic acid. The isolates also showed high sensitivity to the following antimicrobials: amikacin, meropenem, and piperacillin/tazobactam. Overall, the resistance rates among ESBL-producing Enterobacteriaceae decreased from 2007 to 2013. CONCLUSIONS : In our hospital, the increased sensitivity to certain antimicrobial agents seems to be directly related to the implementation of improvements in the methods to prevent and control nosocomial infections in addition to the natural development of other resistance mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors report the magnetic resonance imaging diagnostic features in two cases with respectively lumbar epidural hematoma and cavernous hemangioma of the lumbar epidural space. Enhanced MRI T1-weighted scans show a hyperintense signal rim surrounding the vascular lesion. Non-enhanced T2-weighted scans showed hyperintense signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the consequences of the chronic use of systemic corticosteroids in children with juvenile rheumatoid arthritis by means of evaluating osteochondral effects depicted by magnetic resonance imaging. PATIENTS AND METHODS: We reviewed clinical and magnetic resonance imaging findings in 69 children (72 knees) with juvenile rheumatoid arthritis. Two groups were studied. Group I: 34 (49.3%) children had previous or current use of systemic corticotherapy (22 girls; 12 boys; mean age: 11.3 years; mean disease duration: 5.9 years; mean corticotherapy duration: 2.9 years; mean cumulative dose of previous corticosteroids: 5000 mg); Group II: 35 (50.7%) children had no previous use of corticosteroids (27 girls; 8 boys; mean age: 11.7 years; mean disease duration: 5.3 years). The groups were compared statistically. RESULTS: In the group that had received corticotherapy (Group I), osteochondral abnormalities were significantly correlated to long-standing disease (>3.5 years; p<0.001). This correlation was not found in the group that had no previous history of corticotherapy (Group II). No correlations were established between median dose of corticosteroids and magnetic resonance imaging findings. CONCLUSION: It is important to further investigate the long-term intra-articular effects of systemic corticotherapy to ensure that the side effects of the aggressive therapy will not be more harmful for the joints than the symptoms suffered over the natural course of the disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schizophrenic patients undergoing proton magnetic resonance spectroscopy show alterations in N-acetyl aspartate levels in several brain regions, indicating neuronal dysfunction. The present review focuses on the main proton magnetic resonance spectroscopy studies in the frontal lobe of schizophrenics. A MEDLINE search, from 1991 to March 2004, was carried out using the key-words spectroscopy and schizophrenia and proton and frontal. In addition, articles cited in the reference list of the studies obtained through MEDLINE were included. As a result, 27 articles were selected. The results were inconsistent, 19 papers reporting changes in the N-acetyl aspartate levels, while 8 reported no change. Methodological analysis led to the conclusion that the discrepancy may be due the following factors: (i) number of participants; (ii) variation in the clinical and demographic characteristics of the groups; (iii) little standardization of the acquisition parameters of spectroscopy. Overall, studies that fulfill strict methodological criteria show N-acetyl aspartate decrease in the frontal lobe of male schizophrenics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cardinal tetra (Paracheirodon axelrodi) is the most intensively commercialized ornamental fish from the Rio Negro Basin (Amazonas State, Brasil). Analysis of the stomach and gut contents of fish caught in their natural habitats show conclusively that the cardinal is essentially a predator, feeding on the mesofauna that adheres to submerged litter, roots and waterplants. Microcrustacea and chironomid larvae (Diptera) were the most frequently ingested prey, while algae intake was relatively infrequent. It is argued that the relatively small size of the cardinals captured in their natural habitat is due to the annual migrations imposed by the inundation cycles, rather than to resource limitation, because it is known from earlier investigations of similar habitats, that these plant substrates are densely colonized by the aquatic mesofauna. Cardinals raised in captivity are larger and have higher rates of growth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Bipolar spectrum disorders (BSDs) are prevalent and frequently unrecognized and undertreated. This report describes the development and validation of the Brazilian version of the bipolar spectrum diagnostic scale (B-BSDS), a screening instrument for bipolar disorders, in an adult psychiatric population. METHOD: 114 consecutive patients attending an outpatient psychiatric clinic completed the B-BSDS. A research psychiatrist, blind to the B-BSDS scores, interviewed patients by means of a modified version of the mood module of the Structured Clinical Interview for DSM-IV ("gold standard"). Subthreshold bipolar disorders were defined as recurrent hypomania without a major depressive episode or with fewer symptoms than those required for threshold hypomania. RESULTS: The internal consistency of the B-BSDS evaluated with Cronbach's alpha coefficient was 0.89 (95% CI; 0.86-0.91). On the basis of the modified SCID, 70 patients (61.4%) of the sample received a diagnosis of BSDs. A B-BSDS screening score of 16 or more items yielded: sensitivity of 0.79 (95% CI; 0.72-0.85), specificity of 0.77 (95% CI; 0.70-0.83), a positive predictive value of 0.85 (95% CI; 0.78-0.91) and a negative predictive value of 0.70 (95% CI; 0.63-0.75). CONCLUSION: The present data demonstrate that the B-BSDS is a valid instrument for the screening of BSDs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Assessing the quality of life and the clinical and social-demographic factors associated in schizophrenic spectrum patients (ICD-10 F20-F29) attending CAPS at the programmatic area 3.0. METHODS: A cross-sectional study was carried out in a sample of schizophrenic spectrum patients who have been enrolled in 2008 in CAPS in programmatic area (AP) 3 at Rio de Janeiro city, using MINIPLUS to assess schizophrenia spectrum disorder and use of psychoactive substances, Positive and Negative Symptoms Scale (PANSS) to assess psychiatric symptoms and Quality of Life Scale (QLS-BR) to assess the quality of life. RESULTS: Seventy nine patients were included, of whom 74 (93.7%) presented some impairment in quality of life. The most frequently affected area was occupational performance. Variables that showed a significant association with severe impairment of quality of life were: marital status, race, occupation, who patients lived with, homelessness, having children, previous psychiatric hospitalization, negative symptoms and symptoms designated as not applicable (being characterized by a lack of typical positive and negative symptoms). CONCLUSION: The knowledge of these factors should be crucial to implement health policies and psychosocial rehabilitation programs focused on improving the quality of life of these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To systematically review the scientific literature on the psychometric properties of international instruments for the assessment of autism spectrum disorder (ASD) in the Brazilian population. Methods A search of bibliographic references was conducted in six electronic databases: PsycINFO, PubMed, IndexPsi, Lilacs, Capes (theses and dissertations) and SciELO. The studies were selected by two independent researchers. Results The procedure identified 11 studies of the Brazilian population that encompassed six ASD assessment tools. Given the information provided, the adaptation of the M-CHAT, a screening instrument, was the best conducted. All steps of the adaptation process were described and the changes made to the final version of the instrument were presented, which was not addressed in other studies. In terms of reliability, all of the instruments that assessed internal consistency showed adequate values. In addition, the ADI-R and the CARS adaptations also satisfactorily contemplated inter-rater reliability and test-retest indices, respectively. Finally, all studies aiming to validate instruments showed evidence of validity and sensitivity, and specificity values above 0.90 were observed in the ASQ, ADI-R and ABC. Conclusion Considering both the psychometric aspects and the copyright information, the screening instrument that currently appears to be best indicated for clinical and research use is the M-CHAT. It was also noticed that there are still no specific ASD diagnostic tools available for use in Brazil. This lack of diagnostic instruments consists in a critical situation for the improvement of clinical practice and the development of research in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta). Their ages ranged from 10 to 28 (mean of 16.7) years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%); 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7), mosaics (n=5), and deletions (n=3). No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively). This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cardiac magnetic resonance imaging provides detailed anatomical information on infarction. However, few studies have investigated the association of these data with mortality after acute myocardial infarction. Objective: To study the association between data regarding infarct size and anatomy, as obtained from cardiac magnetic resonance imaging after acute myocardial infarction, and long-term mortality. Methods: A total of 1959 reports of “infarct size” were identified in 7119 cardiac magnetic resonance imaging studies, of which 420 had clinical and laboratory confirmation of previous myocardial infarction. The variables studied were the classic risk factors – left ventricular ejection fraction, categorized ventricular function, and location of acute myocardial infarction. Infarct size and acute myocardial infarction extent and transmurality were analyzed alone and together, using the variable named “MET-AMI”. The statistical analysis was carried out using the elastic net regularization, with the Cox model and survival trees. Results: The mean age was 62.3 ± 12 years, and 77.3% were males. During the mean follow-up of 6.4 ± 2.9 years, there were 76 deaths (18.1%). Serum creatinine, diabetes mellitus and previous myocardial infarction were independently associated with mortality. Age was the main explanatory factor. The cardiac magnetic resonance imaging variables independently associated with mortality were transmurality of acute myocardial infarction (p = 0.047), ventricular dysfunction (p = 0.0005) and infarcted size (p = 0.0005); the latter was the main explanatory variable for ischemic heart disease death. The MET-AMI variable was the most strongly associated with risk of ischemic heart disease death (HR: 16.04; 95%CI: 2.64-97.5; p = 0.003). Conclusion: The anatomical data of infarction, obtained from cardiac magnetic resonance imaging after acute myocardial infarction, were independently associated with long-term mortality, especially for ischemic heart disease death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Pulmonary hypertension is associated with poor prognosis in heart failure. However, non-invasive diagnosis is still challenging in clinical practice. Objective: We sought to assess the prognostic utility of non-invasive estimation of pulmonary vascular resistances (PVR) by cardiovascular magnetic resonance to predict adverse cardiovascular outcomes in heart failure with reduced ejection fraction (HFrEF). Methods: Prospective registry of patients with left ventricular ejection fraction (LVEF) < 40% and recently admitted for decompensated heart failure during three years. PVRwere calculated based on right ventricular ejection fraction and average velocity of the pulmonary artery estimated during cardiac magnetic resonance. Readmission for heart failure and all-cause mortality were considered as adverse events at follow-up. Results: 105 patients (average LVEF 26.0 ±7.7%, ischemic etiology 43%) were included. Patients with adverse events at long-term follow-up had higher values of PVR (6.93 ± 1.9 vs. 4.6 ± 1.7estimated Wood Units (eWu), p < 0.001). In multivariate Cox regression analysis, PVR ≥ 5 eWu(cutoff value according to ROC curve) was independently associated with increased risk of adverse events at 9 months follow-up (HR2.98; 95% CI 1.12-7.88; p < 0.03). Conclusions: In patients with HFrEF, the presence of PVR ≥ 5.0 Wu is associated with significantly worse clinical outcome at follow-up. Non-invasive estimation of PVR by cardiac magnetic resonance might be useful for risk stratification in HFrEF, irrespective of etiology, presence of late gadolinium enhancement or LVEF.