38 resultados para Quantum dot lasers
Resumo:
Plasmodium falciparum resistant strain development has encouraged the search for new antimalarial drugs. Febrifugine is a natural substance with high activity against P. falciparum presenting strong emetic property and liver toxicity, which prevent it from being used as a clinical drug. The search for analogues that could have a better clinical performance is a current topic. We aim to investigate the theoretical electronic structure by means of febrifugine derivative family semi-empirical molecular orbital calculations, seeking the electronic indexes that could help the design of new efficient derivatives. The theoretical results show there is a clustering in well-defined ranges of several electronic indexes of the most selective molecules. The model proposed for achieving high selectivity was tested with success.
Resumo:
The aim of the present study is to evaluate cyst wall and protoscolex as an alternate source of antigen in serodiagnosis of cystic echinococcosis (CE). A total of 90 blood samples, 30 each of confirmed CE cases, disease controls and healthy controls were collected. Dot-ELISA using cyst wall, protoscolex and cyst fluid were used to demonstrate anti-hydatid antibodies. The sensitivity of Dot-ELISA using cyst wall, protoscolex and cyst fluid was 96.66%, 86.66% and 93.33% respectively and the specificity of the assay was 70% for Dot-ELISA using cyst fluid, protoscolex and cyst wall antigens. Results of the present study show that cyst wall and protoscolex can also be an useful source of antigen in detection of hydatid antibodies in the serodiagnosis of CE.
Resumo:
The aim of this study was to estimate the frequency of human toxocariasis in Cauday district, Cajamarca, Peru, using a dot-ELISA test. From June to October 2005, a total of 256 adult subjects were studied. Blood samples were collected for serology by a dot-ELISA test and for hematological examination. Parasitological examination was also carried out in stool samples to check cross-reactions in the dot-ELISA. The frequency observed was 44.92%, with a significant higher proportion of positivity in male subjects. From subjects with positive serology, 45.6% had respiratory symptoms, 40.44% abdominal pain, 32.35% hepatic symptoms, 14.7% cutaneous signs, 13.23% ocular manifestations, 43.38% eosinophilia, and all of these were statistically associated to serology. Among the population evaluated, 90.23% (231/256) were parasitized. From subjects with positive serology, 92.17% had at least one intestinal parasite and the most frequent were: Blastocystis hominis (68.38%), Giardia lamblia (28.68%), Hymenolepis nana (20.0%), Ascaris lumbricoides (15.65%), Entamoeba histolytica/E. dispar (13.24%), Cyclospora cayetanensis (4.41%), Cryptosporidium sp. (1.47%), Enterobius vermicularis (0.87%), Strongyloides stercoralis (0.87%), Taenia sp. (0.87%), and Trichuris trichiura (0.87%). The rate of false positives in the dot-ELISA test was improved by serum absorption each with A. suum antigens, with a decrease of cross-reactions. In conclusion, human toxocariasis is highly frequent in this population and some risk factors like dog/cat ownership, presence of pets within house, and previous history of geophagia were observed in the present study.
Resumo:
Dacron and nitrocellulose were evaluated as matrices for the dot enzyme linked immunosorbent assay (dot-ELISA) for schistosomiasis and compared to indirect immunofluorescence (IMF). Titration of sera from 18 schistosomiasis patients against soluble worm antigen preparation (SWAP) was carried out and sera from healthy individuals from non-endemic areas were used as controls. The IMF was less sensitive than the dot-ELISAs, although the difference was not statistically significant (p > 0.05). The dot-ELISA based on nitrocellulose was as sensitive as that using dacron. Stability did not differ between nitrocellulose and dacron. Specificity was lower when dacron was used than when nitrocellulose was used, although the difference was not statistically significant (p > 0.05). In conclusion, this work showed that nitrocellulose and dacron performed similarly in dot-ELISA, suggesting that they may be used alternatively in population surveillance in endemic areas.
Resumo:
Se estudia el Ensayo Inmunoenzimático en Microgotas sobre Nitrocelulosa (Dot-ELISA)comparando dos preparados antigénicos de formas epimastigotas de cultivo de T. cruzi: 1) la fracción citoplasmática (antígeno citoplasmático y 2) el parásito total fijado previamente con formaldehido (antígeno integral). Se usaron sueros de: 95 pacientes chagásicos con serología convencional positiva, cardiopatía crónica y algunos con xenodiagnóstico positivo; 42 personas sanas y 32 con miocardipatía crónica con serología negativa y 74 pacientes con diferentes patologías incluyendo: sífilis, toxoplasmosis, lupus eritematoso diseminado, con factor reumatoide, leishmaniasis visceral, y leishmaniasis cutánea. Definidos los títulos diagnósticos (cut-off) de 1:512 con antígeno citoplasmático y de 1: 128 con antígeno integral, la especificidad fue 96% para el primero y de 100% para el segundo; mientras que la sensibilidad fue de 100% para ambas. En el estudio comparativo con las pruebas serológicas convencionales examinando 147 sueros tomados de personas referidas al laboratório, Dot-ELISA con antígeno citoplasmático presentó índices deco-positividad de 1,0, co-negatividad de 0,989 y eficiencia 0,993. Dot-ELIS con antígeno integral dió 1,0, 0,979 y 0,986 respectivamente. De acuerdo con esta evaluación, la técnica Dot-ELISA con antígeno integral se presenta como una alternativa práctica para el diagnóstico serológico de la enfermedad de Chagas.
Resumo:
Se realizó estudio seroepidemiológico sobre la infección por Trypanosoma cruzi en habitantes de cuatro comunidades rurales de Venezuela, que presentan diferentes situaciones epidemiológicas en relación a la Enfermedad de Chagas, con la finalidad de evaluar la técnica de Dot-ELISA y compararla con las pruebas serológicas convencionales. En los caseríos de Kamana y caño Hondo del estado Zulia, donde no existe transmisión, la seropositividad fue 15,7% en adultos solamente. En las comunidades de las Rosas y Solano del estado Cojedes, área de alta endemicidad, la seropositividad en los menores de 14 años fue 8,9% y en los mayores de 15,51,6%. En el estudio comparativo con las pruebas serolgicas convencionlaes, Dot-ELISA presentó altos índices de co-positividad, co-negatividad y eficiencia. El valor predictivo positivo de la prueba fue de 66% y 60% con al antígeno citoplasmático e integral respectivamente, en el estado Zulia y 100% y 95% en el estado Cojedes. Estos resultados sugieren que Dot-ELISA puede ser una alternativa práctica para estudios seroepidemiológicos sobre la infección por Trypanosoma cruzi en los paises en desarrollo.
Resumo:
Dacron (polyethylenetherephthalate) is proposed as a matrix for dot-ELISA procedures, as an alternative to nitrocellulose. Plates of dacron were partially hydrazinolyzed and hydrazide groups introduced were converted to azide groups. The derivative dacron-antigen was covalently linked on to the plates through these azide groups. The derivative dacron-antigen was exaustively washed according to CROOK and antigen was still fixed onto the plates. Protein F1A purified from Yersinia pestis was used as a model. Triration of sera from immunized and non immunized rabbits against this protein was carried out by employing the dot-ELISA method. No significant difference was observed using dacron-antigen and nitrocellulose-antigen preparations. However, both procedures showed to have a significant better performance in comparasion with the passive hemagglutination method. The specificity and reproductibility of the dot-ELISA assay using both preparations showed a similar behaviour. Nitrocellulose preparation was stable at 4ºC, 28ºC and -20ºC for 90 days, whereas the dacron-antigen derivative was stable only when stored at 4ºC. Dacron-antigen derivative could be re-used when the spot developing was proceeded using 4-chloro-1-naphtol as substrate.
Resumo:
A new serological assay dot-dye-immunoassay (dot-DIA) was evaluated for the diagnosis of schistosomiasis mansoni. This method consist of four steps: (a) biding of antigens to a nitrocellulose membrane (NC); (b) blocking of free sites of the NC; (c) incubation in specific primary antibody; (d) detection of primary antibody reactivity by color development using second antibody coupled to textile dyes. Sera from 82 individuals, 61 with Schistosoma mansoni eggs in the stool and 21 stool negative were tested by ELISA, dot-ELISA, and dotDIA. A high level of agreement between the methods tested was observed for all sera tested: ELISA x dot-ELISA: 95.1%, ELISA x dot-DIA: 92.7% and dot-ELISA x dot-DIA: 97.6%. In this study, dot-DIA proved to be a feasible, sensitive, rapid and practical test for the diagnosis of shcistosomiasis.
Resumo:
A dot enzyme linked immunosorbent assay (dot-ELISA) was previously developed to detect specific antibodies in rabbits sera immunized against FIA protein obtained from Yersina pestis. This antigen was covalently linked onto the surface of dacron (polyethyleneterephthalate). Here, standard conditions are described for the optimization of this procedure: an amount of 20 ng of FIA protein was fixed onto dacron; anti-rabbit IgG peroxidase conjugate diluted 1:8,000 and 30% non-fat instant milk as blocking substance were used throughout the method. This procedure was compared with that employing nitrocellulose as solid-phase which showed to be more sensitive. However, the method based on dacron did not show false positive reactions against non-immunized rabbits sera at low antigen amount and diluted anti-IgG peroxidase conjugate.
Resumo:
A dot enzyme-linked immunosorbent assay (dot-ELISA) was standardized using excretory-secretory antigens of Toxocara canis for the rapid immunodiagnosis of human toxocariasis. Thirty patients with clinical signs of toxocariasis, 20 cases with other parasitic diseases, and 40 healthy subjects were tested. A total of 0.2 ng of antigen per dot, serum dilution of 1:160 and dilution conjugate of 1:1000 were found optimal. The sensitivity and specificity of the assay were 100 and 95%, respectively. Comparable sensitivity of dot-ELISA and the standard ELISA was obtained, but only 3 cross-reactions occurred in the dot-ELISA, compared with 6 in the standard ELISA. Dot-ELISA is simple to perform, rapid, and low cost. Large-scale screening studies should be done to evaluate its usefulness under field conditions.
Resumo:
Semiconductor nanoparticles, such as quantum dots (QDs), were used to carry out experiments in vivo and ex vivo with Trypanosoma cruzi. However, questions have been raised regarding the nanotoxicity of QDs in living cells, microorganisms, tissues and whole animals. The objective of this paper was to conduct a QD nanotoxicity study on living T. cruzi protozoa using analytical methods. This was accomplished using in vitro experiments to test the interference of the QDs on parasite development, morphology and viability. Our results show that after 72 h, a 200 μM cadmium telluride (CdTe) QD solution induced important morphological alterations in T. cruzi, such as DNA damage, plasma membrane blebbing and mitochondrial swelling. Flow cytometry assays showed no damage to the plasma membrane when incubated with 200 μM CdTe QDs for up to 72 h (propidium iodide cells), giving no evidence of classical necrosis. Parasites incubated with 2 μM CdTe QDs still proliferated after seven days. In summary, a low concentration of CdTe QDs (2 μM) is optimal for bioimaging, whereas a high concentration (200 μM CdTe) could be toxic to cells. Taken together, our data indicate that 2 μM QD can be used for the successful long-term study of the parasite-vector interaction in real time.
Resumo:
The aim of this work was to evaluate a dot-enzyme-linked immunosorbent assay (dot-ELISA) using excretory-secretory antigens from the larval stages of Toxocara canis for the diagnosis of toxocariasis. A secondary aim was to establish the optimal conditions for its use in an area with a high prevalence of human T. canis infection. The dot-ELISA test was standardised using different concentrations of the antigen fixed on nitrocellulose paper strips and increasing dilutions of the serum and conjugate. Both the dot-ELISA and standard ELISA methods were tested in parallel with the same batch of sera from controls and from individuals living in the problem area. The best results were obtained with 1.33 µg/mL of antigen, dilutions of 1/80 for the samples and controls and a dilution of 1/5,000 for the anti-human IgG-peroxidase conjugate. All steps of the procedure were performed at room temperature. The coincidence between ELISA and dot-ELISA was 85% and the kappa index was 0.72. The dot-ELISA test described here is rapid, easy to perform and does not require expensive equipment. Thus, this test is suitable for the serological diagnosis of human T. canis infection in field surveys and in the primary health care centres of endemic regions.
Resumo:
Multicomponent ( Al2O3, CaO, SiO2, MgO) calcium aluminate-based glasses containing Nd3+ were prepared in order to evaluate their possibilities as laser host materials. The refractive index, UV-visible-near IR absorption spectrum, IR and visible luminescence spectra, and fluorescence decay time were measured. Judd-Ofelt model was used to obtain experimental intensity parameters ( omega2, omega4 and omega6), emission cross-section, radiative lifetimes, emission branching ratios and quantum efficiency.